Sign In | Join Free | My futurenowinc.com
futurenowinc.com
Products
Search by Category
Home > Used Measuring & Analysing Instruments >

ASTM E709 230VAC Magnetic Particle Testing Equipment Flaw Detection Black Color

Categories Magnetic Particle Testing Equipment
Brand Name: HUATEC
Model Number: HCDX-230 AC/DC
Certification: CE ISO
Place of Origin: Beijing
MOQ: 1 set
Payment Terms: T/T,paypal, western union
Supply Ability: 500pcs per month
Delivery Time: 3 working days
Packaging Details: Carton
Power: 220V/110V
Elevating power: >4.8kg
Polar distance: 50-200mm
Operating current: AC 3A
Size: 208×48×148
Lamp: White light
Probe weight: 3.2KG
Flexible joint: 2 pairs, 4 sections
Color: Black
Usage: Magnetic Particle Flaw Detection
Product name: magnetic particle testing equipment
Warranty: 12 Months,1 Year
Cycle time: 2 minutes on 2 minutes off
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    ASTM E709 230VAC Magnetic Particle Testing Equipment Flaw Detection Black Color

    Parker B300MRS 230VAC Magnetic Particle Inspection Handy Yoke Magnetic Particle Inspection HCDX-230


    Production standards: ASTM E709 ASTM1444 EN ISO 9934-3 (230V only)


    Magnetic particle flaw detector is a nondestructive testing equipment for surface and near surface crack defects of various ferromagnetic parts.

    Magnetic particle flaw detector can detect the parts with hidden crack defects on the premise of not destroying the material of the detected parts and not affecting the service performance of the detected parts. It is an important quality inspection equipment for product quality control of parts manufacturing enterprises.

    The importance of magnetic particle detector

    1. Hidden defects of ferromagnetic raw materials can be found to avoid loss of parts processing costs;

    2. Hidden defects of ferromagnetic parts can be found to avoid safety accidents;

    3, can find the magnetic parts in the process of processing defects, improve the processing technology;

    4. Fatigue cracks in the stress concentration area of ferromagnetic parts can be found to improve the design process.


    Product features

    Sealed, durable construction

    Chemical and abrasion resistant

    AC and DC operation options for surface and sub-surface inspection

    Exceeds ASTM lifting specifications


    The three modes of power supply can be freely chosen:

    There are places directly connected to AC power supply, which can be directly connected with AC power supply.

    It is possible to use AC magnetized power supply (DC-AC inverter battery pack) to supply AC power without any direct insertion to AC power supply.

    The DC magnetizing power supply (DC battery pack) can be used to realize the DC magnetization function.

    AC magnetizing power supply (DC-AC inverter battery pack) has the functions of voltage regulation, overcharge, over current and over discharge.

    When the lifting force is not enough, the power is automatically cut off to ensure the sensitivity of flaw detection.

    The power display function can display the current battery power, and has the function of sound and light alarm.

    Built in microcomputer chip to stabilize output voltage and ensure detection sensitivity.

    Adjustable magnetization

    Special working waist bag can carry battery pack, magnetic suspension, contrast agent, yoke probe, etc.


    Technical parameter

    Working temperature: -10 ~ +40 C

    Storage temperature: -20 ~ 50 C

    Relative humidity: <80% non condensation

    Work temperature rise: <18 C

    Temporary load rate: >50%

    Sensitivity: A1 standard test piece 15/50 groove clearly displayed.

    AC minimum power hoisting power: >4.5kg (44N)

    DC minimum power hoisting power: >18.1kg (177N)

    Frequency: 50-60Hx


    The HCDX-230 series is a durable, high-strength AC, AC/DC, DC magnetic yoke designed to detect surface and sub-surface indications in the most rugged applications.


    Featuring sealed chemical-resistant construction, articulating legs to contour to any part shape and robust strain-relieved twelve-foot cord for field use, the HCDX-230 is ideal for inspection of welds and other remote testing.


    Solid-state controls allow the operator to use AC magnetic fields for surface indications or DC magnetic fields for sub-surface indications to meet all inspection needs.


    The charging type magnetic particle flaw detector has the characteristics of compact structure, reasonable layout, small size, light weight and convenient portability. The flaw detector can be used directly in alternating current, and can also be used for AC magnetization power supply (AC battery pack) and DC magnetized power supply (DC-AC inverter battery pack), which is efficient and portable. It is suitable for hull weld inspection, high altitude steel structure weld detection and pressure vessel internal operation. This instrument is suitable for steel structure parts of power, metallurgy, petrochemical, machinery and other industries, such as boiler, pressure vessel, pressure pipe, ship body weld and welding structure of various types of ferromagnetic material surface and magnetic particle flaw detection of near surface defect.


    This instrument conforms to the standard requirements of JB/T7411-2012, ASME BPVC,ASTM E709,ASTM E1444,ASTM E3024."electromagnetic yoke flaw detector technical condition".


    Model guide

    1. Technical Specifications:

    Model


    Categories

    HCDX-230

    DC-AC inverter

    With battery

    HCDX-230

    DC

    HCDX-230

    AC

    HCDX-230E

    AC-DC switch

    No battery

    Power supply110V/220V 50/60Hz-12V110V/220V 50/60Hz 12/V110V/220V 50/60Hz110V/220V 50/60Hz
    Charging power110V/220V 50/60Hz-12V110V/220V 50/60Hz 12V//
    BatteryYD-2 Inverter batteryRechargeable battery//
    Working current

    AC 3A

    DC 3A

    3A3A3A(AC-DC Switching Converters)
    Charging duration3h3h//
    Battery duration6h-8h6h-8h//
    Battery size60×96×170mm60×96×170mm
    Aperture time3 ~ 5 seconds on / 3 to 5 seconds off
    Magnetizing length50-200mm50-200mm50-200mm50-240mm

    Lift

    force

    AC≥6㎏/≥4.8㎏≥5.5㎏
    DC≥18.5㎏≥18.5㎏/≥25㎏
    WeightProbe3.2㎏3.2㎏3.2㎏3.5㎏

    Battery

    box

    2.9㎏2.9㎏//

    Figure

    size

    Probe208×48×148208×48×148208×48×148210×60×260

    Battery

    box

    170×96x60170×96x60//

    Standard configuration:

    HCDX-230 DC-AC Inverter AC yoke kit

    Magnetic powder flaw detector host 1

    Power line 1

    Rechargeable Inverter DC battery pack (DC magnetized power supply 110V/220V 50/60Hz) 1

    DC power backpack 1

    Power adapter 1

    DC output connection line 1

    Instrument box 1

    Certificate 1

    Manual 1


    HCDX-230 DC

    Magnetic powder flaw detector host 1

    Power line 1

    Rechargeable DC battery pack (DC magnetized power supply) 1

    DC power backpack 1

    Power adapter 1

    DC output connection line 1

    Instrument box 1

    Certificate 1

    Manual 1


    HCDX-230 AC

    Magnetic powder flaw detector host 1

    Power line 1

    Instrument box 1

    Certificate 1

    Manual 1


    HCDX-230E AC-DC switch

    Magnetic powder flaw detector host 1

    Power line 1

    Instrument box 1

    3A (AC-DC Switching Converters)

    Certificate 1

    Manual 1


    Principles and Applications


    3.1 Charging(with charger or accumulator-HCDX-230 AC-DC,HCDX-230 DC):

    Connect charger to power supply or connect charger to accumulator box with cable. 3 tubes will indicate charged state while charging. The red indicates quickly charged, the yellow indicates slowly charged (may continuously charge for 4 hours) and the green indicates 14 volts already charged. If the tube indicates yellow at start, it can be continuously charged but totally not more than 15 hours.


    3.2 Accumulator

    Accumulator is the power supply of probe. After turn on the switch, the monitoring circle is working. When voltage is over 10.4V, the tube turns green and means power normally supplied. When voltage is reached to 10.4V, the tube turns red flash and means voltage is reached to 10.4V, the tube turns red flash and means voltage is not enough. When voltage is at 10.2V, means self-protection is started and power supply to the probe soon stopped. When the tube continuously red flash, means voltage is not enough. Therefore, the working switch should be turn off and the accumulator should be power recharged.


    3.3Fault detection

    A:When detect it with DC (suitable for HCDX-230 DC,HCDX-230 AC-DC):

    1. Connect probe with cell, when the working switch at position “on” means power is supplied to the probe.
    2. Put the probe on work-piece to be detected and keep it well touched.
    3. Push down the button of probe and spray magnetic powder or magnetic suspension liquid to the area to be detected at the same time and keep it for 2~3seconds.
    4. Release the button of probe and move the probe away and observe the working result carefully.
    5. Move the probe to another area to be detected and repeat the working steps according to 3)and 4) above.

    B:When detect it with AC(suitable for HCDX-230,HCDX-230E AC-DC,HCDX-230 AC-DC)

    1. Put the plug into the socket which should be contacted the earth.
    2. Reference to the working steps 3)and 4) of the Dc when detected.
    3. The implementation of testing using the HCDX-230E, the exchange of the work piece when the selection switch for the exchange of inspection, when placed in the DC to DC testing. Non-magnetic state in the conversion pass selector switch.

    4. Maintenance

    1)The charging duration is not over 15 hours for each time when charging with charging device. Disconnect the battery cable form charging device or turn off the accumulator switch to proven the current flow reversed.

    2)It should be charged as quickly as possible when voltage of accumulator is not enough.

    3)It should be charged for every 2~3 months when the detector is not used for a long time , so as to guarantee serviceable life of the accumulator.

    4)While the probe is used, time of power supplied general 2~3 seconds for each time and maximum is not over 5 seconds. Time of interval is 3~5 seconds.

    5)The rust-proof agent should be added when magnetic suspension liquid used.

    6)Some oil lubricant should be added at moving joint before the probe used. The water, oil and magnetic particles on moving joint should be cleaned out and rust-proof oil should be smear after the probe used.

    7)The power supply should meet the requirements of indications and in good earth contacted when detected with AC.

    8)The switch should be released when moving the probe, so as not resulted of heat to the detector.

    9)Short break is necessary if the detector continuously worked or obviously heated.

    10)Working with the detector, it is not allowed under high temperature, high humidity or raining. The magnetic suspension liquid is not allowed sprayed on the switch, plug or sockets.


    Basic Configuration

    Type

    HCDX-230

    AC-DC

    HCDX-230

    DC

    HCDX-230

    HCDX-220E

    AC-DC

    Main detector,

    Probe&cable

    1 set1 set1 set1 set
    Charge& wire1 piece1 piece//
    Battery box1 box1 box//
    Flexible joint

    2 pairs,

    4 sections

    (on probe)

    2 pairs,

    4 sections

    (on probe)

    2 pairs,

    4 sections

    (on probe)

    2 pairs,

    4 sections

    (on probe)

    Power wire1 piece1 piece//
    Cable1 piece1 piece1 piece1 piece
    Packing case1 piece1 piece1 piece1 piece
    Operation instructions1 piece1 piece1 piece1 piece
    Certifications1 piece1 piece1 piece1 piece

    Quality ASTM E709 230VAC Magnetic Particle Testing Equipment Flaw Detection Black Color for sale
    Send your message to this supplier
     
    *From:
    *To: HUATEC GROUP CORPORATION
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0