Sign In | Join Free | My futurenowinc.com
futurenowinc.com
Products
Search by Category
Home > Plastic Stocks >

Telecom Power System, UPS, Rectifier, Input: 90~280Vac; Output:-43.2~-57.6Vdc; Power:6420

Categories Telecom Power System (Rack Mount UPS)
Place of Origin: China
Model Number: STC-CPL48120ER
MOQ: 1 set
Packaging Details: wooden case
Delivery Time: 15~20 days
Payment Terms: T/T, L/C
Supply Ability: 50000 sets per year
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Telecom Power System, UPS, Rectifier, Input: 90~280Vac; Output:-43.2~-57.6Vdc; Power:6420

    Power System of High Performance and High Reliability
    STC-CPL48120ER Embedded Power System
    Input: 90~280Vac; Output:-43.2~-57.6Vdc; Power: 6420W

    Features

    (1) Total capacity: -53.5Vdc/(10~120)A
    (2) Standard 19in./3U,easy to be embedded to all kinds of telecom equipment and cabinets
    (3) Adoption of active power factor compensation
    (4) Normal operating range of AC input voltage: 90~280Vac
    (5) Operating temperature range: -20℃~ +65℃
    (6) Adoption of softswitch tech with efficiency of 91% or above
    (7) Perfect battery management, LVLD&BLVD
    (8) Hot pluggable
    (9) Excellent lightning proof design applicable to areas with frequent thunderstorms
    (10) Input over/under voltage protection
    (11) Output over voltage/current protection
    (12) Output short circuit protection
    (13) LED indicators on front panel
    (14) Compliant to UL 60950, CSAC22.2 60950-00, VDE0805 IEC60950
    (15) CE mark meets directives of 73/23/EEC and 93/68/EEC

    Application

    (1) Program controlled exchanger
    (2) Access network
    (3) Transmission equipment
    (4) Mobile communication
    (5) Satellite communication ground station
    (6) Microwave communication

    Basing on years development and operating experience, the embedded power system is a newly-designed product, which is of high performance and high reliability. The system size is standard 19in. /3U, can be embedded into all kinds of telecom equipments and cabinets. It is also of wide range of input voltage and operating temperature, high efficiency and the hot plug makes it is easy for maintenance.

    1. System operating principle

    AC power is first input AC-INPUT circuit breaker and then fed into the rectifier module after the EMI filtering. AC-INPUT functions as over load and short circuit protection to AC power. Load LVD contactors KM1, KM2 are connected in series with the LOAD1 and LOAD2. The user’s battery is connected to the DC output through BAT circuit breaker and KM2, and the circuit breaker provides disconnection control, over-load and short-circuit protection to the battery.

    Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the battery will power to the system. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage drops to below -47V (settable), the monitoring module will report the DC under-voltage alarm signal. When the voltage drops to -45.0V (settable), the monitoring module will make KM1 cut off LOAD1 while retaining LOAD2.The power system just powers to LOAD2. When the voltage drops below -43.0V (settable), the KM2 acts to cut off LOAD2 output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values, users can reset).

    Except for battery over-discharge protection, battery or load over-temperature protection function is prohibitive under default condition, users can send command to activate or inactivate according to the demand.

    2. System configuration


    2.1 4 Nos rectifier modules
    Options: CPL4810RM, CPL4815RM, CPL4820RM, CPL4830RM;

    2.2 1 Nos monitoring module

    Options: CPL48D(RS485, LCD), CPL48DI (RS485, TCP/IP, LCD), CPL48I(RS485);

    2.3 1 Nos surge protection module (20KA)

    2.4 Distribution part .
    AC Distribution: single phase, 3 lines, double-pole AC breaker 60A of general power supply;
    DC Distribution: battery fuse 80A×1;
    LVBD: 100A×1;
    LVLD: 200A×1

    1. AC input socket-3 core 2. Fixing hole
    3. MCB 4. Surge protection module
    5. Rectifier module 6. Monitoring module
    7. Load output connectors

    3. Line diagram:


    4. Properties


    (The specifications are for system configured with 2 Nos rectifiers of 30A if not specified.)

    Input

    Parameter

    Min.

    Typical

    Max.

    Unit

    Remark

    Input voltage range

    90

    220

    280

    Vac


    Input frequency

    45

    50

    65

    Hz


    Input current



    37.3

    A


    Power factor

    0.98





    Output

    Parameter

    Min.

    Typical

    Max.

    Unit

    Remark

    Output voltage range

    -43.2

    -53.5

    -57.6

    Vdc


    Output current range

    4Nos rectifiers of 30A

    0


    120

    A

    175~280VAC

    0


    60

    A

    150~175VAC

    0


    45

    A

    90~150VAC

    4Nos rectifiers of 20A

    0


    80

    A

    175~280VAC

    0


    45

    A

    90~175VAC

    4Nos rectifiers of 15A

    0


    60

    A

    175~280VAC

    0


    37.5

    A

    90~175VAC

    4Nos rectifiers of 10A

    0


    40

    A

    175~280VAC

    0


    20

    A

    90~175VAC

    Regulation



    ±1

    %


    Load regulation



    ±1

    %


    Line regulation



    ±1

    %


    Weighted psophometric noise



    2

    mv


    Wide frequency noise voltage



    50

    20

    mv

    mv

    3.4KHz~150KHz

    150KHz~30MHz

    Ripple(Vp-p)



    200

    mv

    Rated input/ output, add 0.1uFfilm capacitor and

    10uF high frequency electrolyte capacitor,

    oscilloscope band width is20MHz

    Current sharing



    ±5

    %


    Output power



    6420

    W

    4Nos rectifiers of 30A



    4280

    W

    4Nos rectifiers of 20A



    3210

    W

    4Nos rectifiers of 15A



    2140

    W

    4Nos rectifiers of 10A

    Output efficiency

    91



    %

    220Vac input

    83



    %

    110Vac input


    Protection



    Parameter

    Unit

    Min.

    Typical

    Max.

    Recovery Property


    Input over-voltage

    Vdc

    285

    305


    Auto recovery


    Input over-voltage recovery set point

    Vdc

    280



    Hysteresis not less than 5V


    Input under-voltage

    Vdc



    85

    Auto recovery


    Input under-voltage recovery set point

    Vdc



    90

    Hysteresis not less than 5V


    Output over-voltage protection set point

    V

    58.5

    59

    61.5

    Lock up


    Output current limiting

    A

    96

    99

    102

    Auto recovery


    Short circuit

    A

    Long-term short circuit permissible; Hiccup when short circuit detected


    Thermal protection

    Auto recoverable under ambient temperature of 60℃.


    Fan failure


    When one fan fails, the module runs with automatic derating and reports alarm till the module high temp protection cuts off the output. When both fans fail, the module cuts off output after reporting alarm.

    Ambient

    Parameters

    Min

    Typical

    Max

    Unit

    Remark

    Operating temp.

    -25


    55

    °C


    Extended operating temp.

    55


    75

    °C

    Operation with derating

    Storage temp.

    -45


    85

    °C


    Humidity

    5


    95

    %

    Relative humidity, non-condensing

    Altitude

    -60

    -200


    4000

    13000

    m

    ft

    For operation above 2500m (5000 ft.), the maximum operation temperature is derated by 2°C. per 305m (1000 ft.)

    Shock and vibration

    operation

    test standard

    drop and tumble






    IEC 68-2

    IEC 721-3-2

    IEC 68-2-31

    Earthquake rating

    4



    Zone


    Noise


    45


    dB

    Relative to fan speed, load and ambient temperature

    Harmonic emission

    EN/IEC61000-3-2

    Radiated emission

    EN55022 - Class B

    Conducted emission

    EN55022 - Class B

    ESD

    EN/IEC 61000-4-2 Level 3 (Contact Discharge 6 kV, Air Discharge 8 kV).

    Radiated immunity

    EN/IEC 61000-4-3 Level 3 (10 V/m).

    Conducted immunity

    EN/IEC 61000-4-6 Level 3 (10Vrms).

    EFT/B

    EN/IEC 61000-4-4 Level 3 (2 kV, 5 kHz Repeat)

    Lightning surge


    Common mode 4kV, differential mode 2kV.

    AC input should bear lightning strike impact current waveform of 8/20us, ±5 times for impacts of 5KA

    Isolation properties

    input-chassis

    input - output

    output - chassis


    1500

    3000

    500




    Vac Vac Vdc


    Leakage current



    3.5mA


    264Vac Input

    Insulation resistance

    10MΩ




    Tested at 500Vdc


    Mechanical spec.

    Length (in./mm)

    19/482.6

    Width (in./mm)

    10/255

    Height (in./mm)

    5.14/130.5

    Weight (kg)

    ≤11