Humidity testing Powerful air circulator smooth airflow Temperature Chamber

Categories Temperature Humidity Chamber
Brand Name: Haida
Model Number: HD-E702
Certification: CE,,ISO
Place of Origin: China
MOQ: 1
Price: Negotiation
Payment Terms: L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability: 75 Piece / Pieces Per Month
Delivery Time: 15 Days After Order
Packaging Details: Strong Wooden Case
Usage: Constant Temperature and Humidity Testing Machine
Humid. range: 10~ 98 percent R.H.
Resolution: 0.01°C, 0.1 percent, P.I.D control
Heating up: -40°C ~ +100°C within 45 min
Heating down: 20°C~ -20°Cwithin 40min
Power: AC220V±10 percent 50/60Hz
Use: temperature test chambers
Company Info.
Hai Da Labtester
Verified Supplier
View Contact Details
Product List
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Humidity testing Powerful air circulator smooth airflow Temperature Chamber

    Humidity testing Powerful Air Circulator Smooth Airflow Temperature Chamber


    Temperature and humidity chamber.pdf


    1. Performance


    Humidity testing Powerful air circulator smooth airflow Temperature Chamber can simulate both temperature and humidity. Controlled humidity from 10% RH to 95% RH can be maintained within the dry-bulb temperature range of +10°C to +85°C, limited by a 6°C dew point. For lower dew point conditions (low RH or relative humidity at low dry-bulb temperatures), you will need dry air purge or GN2 (gaseous nitrogen) purge. See the humidity range chart on the specification page of each temperature-humidity chamber for humidity range limits.


    Questions for Performance Evolution Request:


    temperature test chambers


    System & Performance Options

    • Low and Ultra-Low Humidity Extends the humidity control range. (Normal Humidity Range Diagramed)
    • Water-cooling system.
    • Dry Air Purge keeps moisture in the chamber extremely low by purging with -40 °C. Compressed air supply required
    • Additional shelves, 50 Kg loading
    • Cable ports with flexible silicone plug, 50 , 100, 150mm or customer specific diameters

    2. Specifications of Stability High Low Temperature and Humidity Test Machine:


    Range – 70 to 150°C

    Temp/Humidity

    HD-E702-100-7

    HD-E702-150-7

    HD-E702-225-7


    HD-E702-408-7

    HD-E702-800-7

    HD-E702-1000-7

    Temp-only

    HD-E702-100T-7

    HD-E702-150T-7

    HD-E702-225T-7


    HD-E702-408T-7

    HD-E702-800T-7

    HD-E702-1000T-7

    Temperature Range:

    -70°C ~150°C

    Cooling Capacity

    ~ 2.5 kW at -50°C

    ~ 3 kW at -50°C

    ~ 5 kW at -50°C

    ~ 6.5 kW at-50°C

    ~ 8.5 kW at -50°C

    ~ 9 kW at - -50°C

    Heating System

    ~ 5 kW

    ~ 5 kW

    ~ 5.5 kW

    ~6.5 kW

    ~ 8.5 kW

    ~ 9 kW

    Temperature Fluctuation:

    ±0.5°C

    Temperature Gradient:

    ±0.5°C~±0.2°C

    Heating Rate†:

    ≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

    Cooling Rate†:

    ≥1℃ / min average (Advance model 5 - 15℃ / min)

    Humidity Range:

    10%~95%RH (Ref to Normal Humidity Range Diagramed)

    Humidity Fluctuation:

    ±1.5%RH~±2.0%RH

    Humidity Gradient:

    ±3%RH

    Dimensions

    Workspace dimensions
    (WxDxH)mm:

    500x400x500

    HD-E702-100

    600x500x500

    HD-E702-150

    750x500x600

    HD-E702-225


    850x650x800

    HD-E702-800

    1000x1000x800

    HD-E702-800

    1000x1000x1000

    HD-E702-1000

    Exterior dimensions
    (WxDxH)mm:

    1400x850x1050

    1500x950x1050

    1650x950x1150


    1750x1050x1350

    1900x1450x1350

    1900x1450x1550

    Site Requirements

    Electrical Supply:

    208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

    Humidity Water

    Distilled water

    Condensate Drain:

    1/2" hose connection (gravity drain)


    Range – 40 to 150°C


    Temp/Humidity

    HD-E702-100-4

    HD-E702-150-4

    HD-E702-225-4


    HD-E702-408-4

    HD-E702-800-4

    HD-E702-1000-4

    Temp-only

    HD-E702-100T-4

    HD-E702-150T-4

    HD-E702-225T-4


    HD-E702-408T-4

    HD-E702-800T-4

    HD-E702-1000T-4

    Temperature Range:

    -40°C ~150°C

    Cooling Capacity

    ~ 2 kW at -20°C

    ~ 2.5 kW at -20°C

    ~ 4.5 kW at -20°C

    ~ 5.5 kW at-20°C

    ~ 8 kW at -20°C

    ~ 8.5 kW at - -20°C

    Heating System

    ~ 5 kW

    ~ 5 kW

    ~ 5.5 kW

    ~6.5 kW

    ~ 8.5 kW

    ~ 9 kW

    Temperature Fluctuation:

    ±0.5°C

    Temperature Gradient:

    ±0.5°C~±0.2°C

    Heating Rate†:

    ≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

    Cooling Rate†:

    ≥1℃ / min average (Advance model 5 - 15℃ / min)

    Humidity Range:

    10%~95%RH (Ref to Normal Humidity Range Diagramed)

    Humidity Fluctuation:

    ±1.5%RH~±2.0%RH

    Humidity Gradient:

    ±3%RH

    Dimensions

    Workspace dimensions
    (WxDxH)mm:

    500x400x500

    HD-E702-100

    600x500x500

    HD-E702-150

    750x500x600

    HD-E702-225


    850x650x800

    HD-E702-800

    1000x1000x800

    HD-E702-800

    1000x1000x1000

    HD-E702-1000

    Exterior dimensions
    (WxDxH)mm:

    1400x850x1050

    1500x950x1050

    1650x950x1150


    1750x1050x1350

    1900x1450x1350

    1900x1450x1550

    Site Requirements

    Electrical Supply:

    208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

    Humidity Water

    Distilled Water

    Condensate Drain:

    1/2" hose connection (gravity drain)


    3. Features:

    Stainless steel exterior
    Full thermal break around doorframe
    One 50mm (2") diameter cable port on left, with flexible silicone plug
    Three levels of overheat protection
    115V main power for BTL-433 model
    High performance and quiet operation (65 dBa)
    Easy lift-off service panels, electrical access on left



    WATLOW F4T PROGRAMMER/CONTROLLER


    Popular PID controller with touch-screen operation
    Stores 40 different profiles
    Step types include: ramp, soak, jump/repeat, auto-start, and end
    Ethernet interface for remote monitoring and operation


    Standard Features:

    • Stainless# 304 steel for interior
    • Paint steel for exterior
    • Foam-insulated door for rigidity and long life
    • Plastic water tank easy for maintenance
    • Observation Window with frost free function
    • High performance refrigeration system
    • Easy user interface for TEMI-880 PLC controller
    • One 100mm cable port/ Customer specified
    • One shelve, 10 Kg loading & 4 casters included
    • Van Type Sirocco,L134,Fan
    • PID controlled-Stainless Steel Humidifier
    • DuPont R-404A [No Fluorine] Refrigerant / 23 for below -40 °C
    • USB port for data output
    • Anti-explosive interior lamps
    • Data logging chart recorders, paperless recorders stored data in the PLC.

    Performance indicators


    Temperature Range RT + 10 ℃ ~ 100 ℃ Humidity 80 ~ 98% R · H fluctuation / uniformity ≤ ± 0.5 ℃ / ± 2 ℃ temperature deviation +2%, - 3% R · H Heating time of about 20min at room temperature ~ 100 ℃ temperature control ± 1 ℃ ± 2%



    Control System


    Imported microcomputer temperature controller wet integrated controller (display directly percent humidity).
    Accuracy range setting accuracy: temperature ± 0.1 ℃, humidity ± 0.1% R · H, indicating accuracy: temperature ± 0.1 ℃, temperature ± 0.1% R · H temperature and humidity sensors platinum platinum resistance · PT100Ω.
    Heating system is completely independent system, electric heating nichrome heater.
    Isolated external humidification systems, stainless steel boiler type shallow surface evaporative humidifier.
    Circulatory system temperature low noise air conditioning motors, leafy centrifugal wind wheel.


    Heating system


    Far-infrared heating using nickel-chromium alloy heating wire heating speed;
    High temperature, low temperature completely independent systems;
    Temperature control P · I · D + S · S · R system with channel coordination control;
    Temperature control the output power by the microcomputer calculus, to achieve high accuracy and high efficiency power efficiency.



    Cooling System


    To ensure the chamber of cooling rate and minimum temperature requirements, the chamber of the refrigeration system cascade refrigeration system consisting of imported compressor, the refrigeration system has a reasonable match, high reliability and easy maintenance.
    Refrigeration works: a refrigeration cycle are used against the card if the cycle, which consists of two isothermal and two adiabatic processes, whose process is as follows: a refrigerant through the compressor adiabatic compression to a higher pressure, the power consumption of the exhaust gas temperature, after the refrigerant through the condenser isothermally in and around medium heat exchange medium heat to four weeks. After the refrigerant flows through the shutoff valve adiabatic expansion work, when the refrigerant temperature decreases. Finally, the refrigerant passes through the evaporator isothermal heat from high temperature object, the object to be cooled so that the temperature is lowered. This loop again and again to achieve the purpose of cooling.


    4. Professional Stability High Low Temperature and Humidity Test Machine view:

    temperature test chambers

    (Advanced refrigeration design is especially compact for HD-Series Chambers)

    Quality Humidity testing Powerful air circulator smooth airflow Temperature Chamber for sale
    Send your message to this supplier
     
    *From:
    *To: Hai Da Labtester
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0