Sign In | Join Free | My futurenowinc.com
futurenowinc.com
Products
Search by Category
Home > Diesel Generators >

3 Phase Ratings Perkins Diesel Generator , 1104A-44TG2

Categories Perkins Diesel Generator
Place of Origin: China
Brand Name: GSKA
Model Number: JP-P88E1
MOQ: 20-30 pieces
Price: Negotiable
Packaging Details: Standard plywood and wood package.the actual package size against goods size and handle requires.
Delivery Time: 3-5 days on receipt of official sales contract
Payment Terms: L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability: 500 pieces per Month
Port:: HongKong or ShenZhen,ShangHai,Dalian as required
CertifiCAT-partsion: CE/RoHs/ISO9001
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

3 Phase Ratings Perkins Diesel Generator , 1104A-44TG2


1. Standby power : 70.4 KW

2.Engine Make & Model: Perkins 1104A-44TG2

3.Alternator Model: LL2014L

4.Circuit Breaker Type: 3 Pole MCB / 3 Pole MCCB

5.Cooling Method: Water Governing

6.Type: Mechanical Governing

7.Class: ISO 8528 G2

8.Compression Ratio: 17.25:1

9.Displacement: l (cu.in) 4.4 (268.5)

10.Bore/Stroke: mm (in) 105.0 (4.1)/127.0 (5.0)

11.Moment of Inertia: kg m² (lb. in²) 1.14 (3896)


3 Phase Ratings Perkins Diesel Generator , 1104A-44TG2


Output Ratings

Generating Set Model

* JPP88E1

Prime* Standby*

380-415V, 50 Hz

80.0 kVA 88.0 kVA

64.0 kW 70.4 kW

480V, 60 Hz

90.0 kVA 100.0 kVA

72.0 kW 80.0 kW

  • Refer to ratings definitions on page 4.

Ratings at 0.8 power factor.



Technical Data

Engine Make & Model:

Perkins 1104A-44TG2

Alternator Model:

LL2014L

Base Frame Type:

Heavy Duty FabriCAT-parts-partsed Steel

Circuit Breaker Type:

3 Pole MCB / 3 Pole MCCB

Frequency:

50 Hz 60 Hz

Engine Speed: RPM

1500 1800

Fuel Tank Capacity: litres (US gal)

175 (46.2)

Fuel Consumption: P80P1 l/hr (US gal/hr)

18.0 (4.8) 21.3 (5.6)

Fuel Consumption: P88E1 l/hr (US gal/hr)

19.9 (5.3) 23.7 (6.3)

P80P1 / P88E1


Engine Technical Data


Physical Data

Manufacturer: Perkins

Model: 1104A-44TG2

No. of Cylinders/Alignment: 4 / In Line

Cycle: 4 Stroke

Induction: Turbocharged

Cooling Method: Water Governing

Type: Mechanical Governing

Class: ISO 8528 G2

Compression Ratio: 17.25:1

Displacement: l (cu.in) 4.4 (268.5)

Bore/Stroke: mm (in) 105.0 (4.1)/127.0 (5.0)

Moment of Inertia: kg m² (lb. in²) 1.14 (3896)

Engine Electrical System:

-Voltage/Ground: 2/Negative

-Battery Charger Amps: 65

Weight: kg (lb)

- Dry: 463 (1021)

- Wet: 485 (1069)


Air System 50 Hz 60 Hz


Air Filter Type: Replaceable

Element Combustion Air Flow:m³/min (cfm)

-Standby: 5.1 (180) 6.4 (226)

-Prime: 4.8 (170) 6.1 (215)

Max. Combustion Air Intake Restriction: kPa (in H2O) 8.0 (32.1) 8.0 (32.1)

Radiator Cooling Air Flow:m³/min (cfm) 121.2 (4280) 140.4 (4958)

External Restriction to Cooling Air Flow: Pa (in H2O) 120 (0.5) 120 (0.5)


Cooling System 50 Hz 60 Hz


Cooling System Capacity:l (US gal) 13.0 (3.4) 13.0 (3.4)

Water Pump Type: Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby: 50.4 (2866) 55.8 (3173)

-Prime: 45.9 (2610) 51.6 (2934)

Heat Radiation to Room:kW (Btu/min)

-Standby: 20.8 (1183) 22.7 (1291)

-Prime: 19.0 (1081) 20.5 (1166)

Radiator Fan Load: kW (hp) 1.0 (1.3) 1.7 (2.3)

Cooling system designed to operate in ambient conditions up to 50°C (122°F).


Performance 50 Hz 60 Hz


Engine Speed: RPM 1500 1800

Gross Engine Power: kW (hp)


-Standby: 80.7 (108.0) 92.6 (124.0)

-Prime: 73.4 (98.0) 84.2 (113.0)

BMEP: kPa (psi)

-Standby: 1468.0 (212.9) 1403.0 (203.5)

-Prime: 1335.0 (193.6) 1276.0 (185.1)

Regenerative Power: kW 7.0 9.0


LubriCAT-parts-partsion System

Oil Filter Type: Spin-On, Full Flow

Total Oil Capacity l (US gal): 8.0 (2.1)

Oil Pan l (US gal): 7.0 (1.8)

Oil Type: AP1 CG4 15W-40

Cooling Method: Water


Fuel System


Fuel Filter Type: Replaceable

Element Recommended Fuel: Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)


110% 100% 75% 50%

Load Load Load Load

P80P1


50 Hz 19.9 (5.3) 18.0 (4.8) 13.6 (3.6) 9.5 (2.5)

60 Hz 23.7 (6.3) 21.3 (5.6) 16.2 (4.3) 11.6 (3.1)

P88E1


50 Hz 19.9 (5.3) 14.9 (3.9) 10.3 (2.7)

60 Hz 23.7 (6.3) 17.9 (4.7) 12.6 (3.3)


(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)


Exhaust System 50 Hz 60 Hz

Silencer Type: Level 1

Silencer Model & Qty: SD80 (1)

Pressure Drop Across

Silencer System: kPa (in Hg) 1.17 (0.345) 1.97 (0.581)

Silencer Noise Reduction

Level: dB 16 16

Max. Allowable Back

Pressure: kPa (in. Hg) 10.0 (3.0) 15.0 (4.4)

Exhaust Gas Flow:

m³/min (cfm)

-Standby: 13.3 (470) 15.9 (560)

-Prime: 12.5 (441) 15.0 (530)

Exhaust Gas Temperature: °C (°F)

m³/min (cfm)

-Standby: 580 (1076) 560 (1040)

-Prime: 555 (1031) 535 (995)

P80P1 / P88E1


Alternator Performance Data



Data Item

50 Hz 60 Hz

415/240V

400/230V

230/115V

200/115V

380/220V

220/110V

220/127V

480/277V

240/139V

380/220V

220/110V

240/120V

208/120V

230/115V

440/254V

220/127V


Motor Starting Capability* kVA


218


206


189


240


239


161


188


176


207


Short Circuit Capacity** %


300


300


300


300


300


300


300


300


300


Reactances: Per Unit


Xd X'd X''d


2.400


0.080


0.040


2.590


0.090


0.043


2.860


0.100


0.048


2.140


0.070


0.036


2.420


0.080


0.040


3.870


0.130


0.064


3.230


0.110


0.054


3.490


0.120


0.058


2.880


0.100


0.048


Reactances shown are applicable to prime ratings

  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.


Alternator Technical Data


Physical Data Operating Data


Manufacturer: FG WILSON


Overspeed: RPM 2250


Model: LL2014L


Voltage Regulation (steady state) (%): + /- 0.5


No. of Bearings: 1


Wave Form NEMA = TIF: 50


Insulation Class: H


Wave Form IEC = THF: 2.0%


Winding Pitch Code: 2/3 - 6


Total Harmonic Content LL/LN: 4.0%


Wires: 12

Supression is in line with European Standard

Radio Interference: EN61000-6


Ingress Protection Rating: IP23


Radiant Heat: kW (Btu/min)


-50 Hz: 6.9 (392)


-60 Hz: 8.0 (455)


Excitation System: SHUNT


AVR Model: R230

P80P1 / P88E1


Technical Data


3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz, 1800 RPM



Voltage Prime Model Standby Model Voltage Prime Model Standby Model

P80P1 P88E1 P80P1 P88E1


kVA kW

kVA kW


kVA kW

kVA kW

415/240V

80.0 64.0

88.0 70.4

480/277V

90.0 72.0

100.0 80.0

400/230V

80.0 64.0

88.0 70.4

220/127V

90.0 72.0

100.0 80.0

380/220V

80.0 64.0

88.0 70.4

380/220V

88.0 70.4

97.0 77.6

230/115V

80.0 64.0

88.0 70.4

240/120V

90.0 72.0

100.0 80.0

220/127V

80.0 64.0

88.0 70.4

230/115V

90.0 72.0

100.0 80.0

220/110V

80.0 64.0

88.0 70.4

440/254V

90.0 72.0

100.0 80.0

200/115V

80.0 64.0

88.0 70.4

220/110V

88.0 70.4

97.0 77.6




208/120V

90.0 72.0

100.0 80.0




230/115V

90.0 72.0

100.0 80.0



Definitions

Standby Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).


Prime Rating

These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.


Standard Reference Conditions

Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.



Weights and Dimensions


Weights: kg (lb) Dimensions: mm (in)



Net (+ lube oil)


1061 (2339)


Length


2149 (84.6)

Wet (+ lube oil & coolant)

1074 (2368)

Width

752 (29.6)

Fuel, lube oil & coolant

1219 (2687)

Height

1366 (53.8)


General Data


Documents

A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.



Generating Set Standards

The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.



Warranty

All equipment carries full manufacturer's warranty.



Quality 3 Phase Ratings Perkins Diesel Generator , 1104A-44TG2 for sale
Send your message to this supplier
 
*From:
*To: Guangdong ALI Testing Equipment Co,.Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0