| Sign In | Join Free | My futurenowinc.com | 
 | 
| Categories | Relay Test System | 
|---|---|
| Place of Origin: | China | 
| Brand Name: | Kingsine | 
| Certification: | ISO9001,CE | 
| Model Number: | K3063L | 
| MOQ: | 1 set | 
| Delivery Time: | 15 working days | 
| Payment Terms: | T/T in advance ,L/C | 
| Supply Ability: | 50 sets/ month | 
| Company Info. | 
| Kingsine Electric Automation Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Digital Relay Test System
1. Easy test
2. Operation menu, Simple operation
3. Power:2000VA
Friendly PC software for easy operation!
K30 series relay tester is extremely design for overseas user, with Friendly PC software as your need, unique features and functions helps you all the way!
1. Unique self-protection system assure the powerful protection when instrument is operating, automatic
stop the output when the network is abnormal ;
2. Unique power switch and amplifier technology, so the output
precision and power efficiency and factor
are increased, which conforms to international tendency of energy
save and environmental protection;
3. With alarm function of housing grounding testing and external
voltage input, to guaranty personal
security;
4. Two in one of meter and source, with function of both internal
and external testing, self-calibration,
oscillograph, and the duration of each oscillograph reaches 50S
(optional function);
5. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A
(Poleless and adjustable);
6. Function of transducer and energy meter testing (optional
function);
7. Testing interface offer unique output monitoring function and
Pre-curve-tracing function, helps more on
the spot analysis;
Technical Data of K3063L
| Voltage generators | ||
| Setting Range | 4-phase AC (L-N) | 4 x 0 ... 130 V | 
| 2-phase AC (L-L) | 2 x 0 ... 260 V | |
| Power | 4-phase AC (L-N) | 4 x 70VA, at 0 ... 130 V | 
| 2-phase AC (L-L) | 2 x 110VA, at 0 ... 260 V | |
| Accuracy | <0.07% reading + 0.03% range guaranteed at 0 ... 130 V <0.02% reading + 0.01% range typical at 0-130V | |
| Resolution | 1mV | |
| Current generators | ||
| Setting Range | 6-phase AC (L-N) | 6 x 0 ... 30 A | 
| 3-phase AC (2L-N) | 3 x 0 ... 60 A (Group A II B) | |
| 1-phase AC (3L-N) | 1 x 0 ... 180 A | |
| Power | 6-phase AC (L-N) | 6x 450VA , at 0 ... 30A | 
| 3-phase AC (2L-N) | 3x 600VA, at 0 ... 60A (Group A II B) | |
| 1-phase AC (3L-N) | 1 x 1500 VA, at 0 ... 180A (Max.) | |
| Accuracy | <0.07% reading + 0.06% range guaranteed at 0-30A <0.02% reading + 0.02% range typical at 0-30A | |
| Resolution | 1mA | |
| Generators, general | ||
| Frequency | Range | 0 ... 1000 Hz | 
| Accuracy / drift | Error < 0.001Hz at 10 ... 65Hz, Error < 0.01Hz at 65Hz...450Hz Error < 0.02Hz at 450Hz...1000Hz | |
| Resolution | 0.001Hz | |
| Phase | Range | - 360° ... +360° | 
| Accuracy / drift | Error < 0.2 ° | |
| Resolution | 0.1° | |
| Timer | Range | Infinite | 
| Accuracy / drift | Error<0.1ms | |
| DC generators | ||
| Voltage ranges | 0 ... 300V/110W | |
| Current ranges | 0 ... 20A/300W | |
| Accuracy | <0.07% reading + 0.03% range guaranteed at 0-300V <0.04% reading + 0.02% range typical at 0-300V | |
| <0.14% reading + 0.06% range guaranteed at 0-20A <0.05% reading + 0.02% range typical at 0-20A | ||
| Resolution | 1mA; 1 mV | |
| Aux DC Supply | ||
| Range | 0...300V/110W | |
| Binary inputs | ||
| Number | 8 pairs | |
| Compatible Voltage | 10V ... 250V DC | |
| Binary outputs | ||
| Number | 4 Pairs | |
| Capacity | 250V/3A AC/DC | |
| Synchronization | ||
| Synchronization mode | GPS | |
| Harmonic | ||
| Harmonic overlap times | 2 ... 20 times | |
| Power supply | ||
| Nominal input voltage | 85V…264V ac | |
| Power | 2000VA | |
| Nominal frequency | 47Hz….65Hz | |
| Environmental conditions | ||
| Operation temperature | -5°C ... 55 °C | |
| Storage temperature | -20°C ... 75 °C | |
| Humidity range | 5% ... 90 %, non-condensing | |
| Weight | 17.5 KG | |
| Dimensions | 480(D)×140 (W)×360 (H) mm | |
| PC connection | RJ45, | |
K30 Series Protection Relay Test Set:
| Model | Channels | AC Outputs | 
| K3063i / K3063Li | 10 output channels | 6*30A/3*40A/4*300V | 
| K3030i / K3030Li | 7 output channels | 3*30A/4*300V | 
| K3066 | 13 output channels | 6*20A/3*40A/7*130V | 
| K3063 | 10 output channels | 6*20A/3*40A/4*130V | 
| K3040 | 7 output channels | 3*40A/4*130V | 
| K3030 | 7 output channels | 3*30A/4*130V | 
Major Functions:
| Items | IEEE(R) No. | 
| Synchronization relay | |
| Fault transplay | |
| GPS Synchronization | |
| Overcurrent relays | 50/76 | 
| Inverse time overcurrent relays | 51 | 
| Undercurrent relays | 37 | 
| Ground fault relays | 50 | 
| Directional overcurrent relays | 67 | 
| Directional ground fault relays | 67N | 
| Overvoltage relays | 59 | 
| Undervoltage relays | 27 | 
| Directional voltage relays | 91 | 
| Directional power relays | 32 | 
| Power factor relays | 55 | 
| Differential protection (differential circuits) | 87 | 
| Distance protection equipment (phase by phase) | 21 | 
| Negative sequence overcurrent relays | 46N | 
| Motor overload protection | 51/86 | 
| Automatic reclosing devices | 79 | 
| Tripping relays | 94 | 
| Voltage regulating relays | |
| Overimpedance relays, Z> | |
| Underimpedance relays, Z | |
| Time-delay relays | 
|   | 
 2000VA Protection Relay Test Kit , Power 4-Phase AC (L-N) K3063Li
                                                                                    
                        
                        
                        
                                                            2000VA Protection Relay Test Kit , Power 4-Phase AC (L-N) K3063Li
                                                    
                        
                     Portable Protection Relay Test System , 7 Phase Voltage / 250V K3066L
                                                                                    
                        
                        
                        
                                                            Portable Protection Relay Test System , 7 Phase Voltage / 250V K3066L
                                                    
                        
                     7 Phase Voltage Protection Relay Tester / Overcurrent Test K3066Li
                                                                                    
                        
                        
                        
                                                            7 Phase Voltage Protection Relay Tester / Overcurrent Test K3066Li
                                                    
                        
                     IEC61850-9-1 Optical Digital Relay Test System / Transient Test KF900
                                                                                    
                        
                        
                        
                                                            IEC61850-9-1 Optical Digital Relay Test System / Transient Test KF900
                                                    
                        
                     Self  Protection 6 Phase AC Relay Test Unit / Power Meter Test K3063L
                                                                                    
                        
                        
                        
                                                            Self  Protection 6 Phase AC Relay Test Unit / Power Meter Test K3063L
                                                    
                        
                     High Voltage Relay Test Device , 7 Phase AC / RJ45 / GPS Mode K3066L
                                                                                    
                        
                        
                        
                                                            High Voltage Relay Test Device , 7 Phase AC / RJ45 / GPS Mode K3066L
                                                    
                        
                     CE Protection Relay Test System , 4 Phase AC (L-N) 250V / 3A K3063Li
                                                                                    
                        
                        
                        
                                                            CE Protection Relay Test System , 4 Phase AC (L-N) 250V / 3A K3063Li
                                                    
                        
                     Optical Digital Relay Test System , 50Hz / 220V / 850nm KF900
                                                                                    
                        
                        
                        
                                                            Optical Digital Relay Test System , 50Hz / 220V / 850nm KF900
                                                    
                        
                     High Power Protection Relay Test System Set 220V / 2000VA K3063L
                                                                                    
                        
                        
                        
                                                            High Power Protection Relay Test System Set 220V / 2000VA K3063L
                                                    
                        
                     6 Phase Relay Test System KINGSINE KF900A Protection Relay Tester
                                                                                    
                        
                        
                        
                                                            6 Phase Relay Test System KINGSINE KF900A Protection Relay Tester