Sign In | Join Free | My futurenowinc.com
futurenowinc.com
Products
Search by Category
Home >

ISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for Medical

Categories Laparoscopic Surgical Instruments
Model NO.: HF2001.1
Size: Phi 10*330mm
Specifications: Single Action, for Flat-Middle Clip
OEM: Acceptable
ODM: Acceptable
Transport Package: Standard Export Packing
Specification: Steel
Trademark: Vanhur
Origin: Tonglu, Zhejiang, China
HS Code: 9018909919
Supply Ability: 500 PCS/Month
Type: Clip Applier
Application: Abdominal
Material: Steel
Feature: Reusable
Certification: CE, FDA, ISO13485
Group: Adult
Customization: Available | Customized Request
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

ISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for Medical

1 Introduction:
The titanium ligating applier is always used with titanium clips in endoscopic for ligating tissue and vessel. We provide three standard colour coding for easy identification. And we also can manufacture the type what you want.

2 Specifications
a. Adopt high quality stainless steel material.
b. Corrosion resistant
c. Tough construction
d. Large, lightweight rotation knob allows one-finger, 360° rotattion of applier shaft.
e. Flush ports for thorough cleaning

ModelNameSpecifications
HF2001.1Titanium clip applier, for flat-middle clip, single actionΦ10×330mm
HF2001.1BTitanium clip applier, for large clip, single actionΦ10×330mm
HF2001.2Titanium clip applier, for flat-middle clip, dual actionΦ10×330mm
HF2001.3Titanium clip applier, for flat-middle clip, side-loadedΦ10×330mm
HF2001.4Titanium clip applier, for small clipΦ5×330mm
HF2001.5Titanium clip applier, for flat middle clip, distal head disassemblyΦ10×330mm

3 Packing & Shipping:
Package detail:Poly bag and special shockproof paper box.
Delivery detail:By air
Laparoscope Instruments Titanium Clip Applicator
Laparoscope Instruments Titanium Clip ApplicatorLaparoscope Instruments Titanium Clip ApplicatorLaparoscope Instruments Titanium Clip ApplicatorLaparoscope Instruments Titanium Clip ApplicatorLaparoscope Instruments Titanium Clip Applicator


FAQ




How to perform tissue cutting and coagulation in laparoscopic surgery?


In laparoscopic surgery, tissue cutting and coagulation is a delicate and technically demanding process, which usually involves the use of advanced electrosurgical instruments. Here are some key steps and technical points of this process:


Correct use of electrosurgical instruments: Electrosurgical instruments, such as electrocoagulation hooks, electrocoagulation forceps or ultrasonic scalpels, are commonly used tools in laparoscopic surgery. They can simultaneously achieve tissue cutting and coagulation and reduce bleeding. In order to protect the function of important organs such as the ovaries, it is particularly important to select electrosurgical instruments with less thermal damage to ensure that the damage to surrounding tissues during cutting is minimized. The range of damage is usually controlled to about 3mm.


Pre-separation technology: Before direct electrocoagulation or cutting, mechanical separation or hydrodissection is usually used to define the cutting line, which helps to reduce accidental damage to healthy tissues. Especially for adhesion tissues, such as adhesions of fallopian tubes and ovaries, separation is performed first to restore their normal function.


Combination of sharp and blunt separation: Sharp separation uses scissors, electric scalpels, etc. for precise cutting, while blunt separation uses instruments such as grasping forceps to push away tissue. The combination of the two can expose the surgical area more safely and reduce damage.


Precise hemostasis: It is very important to perform precise hemostasis immediately at the same time or after cutting. Electrocoagulation instruments can be used to seal small blood vessels and reduce bleeding. The operator needs to judge when and where to apply electrocoagulation based on the color, texture and amount of bleeding of the tissue to avoid tissue damage caused by excessive electrocoagulation.


Energy setting adjustment: The energy output of the electrosurgical device should be appropriately adjusted according to the surgical site and tissue type to achieve the best cutting effect and minimize secondary damage. Low energy settings are used for more delicate operations, and high energy is used for rapid cutting or processing of larger blood vessels.


Continuous monitoring: During the operation, the doctor will continuously monitor the tissue response and electrosurgical effect to ensure that the operation is safe and effective.


Tissue protection measures: For delicate or sensitive tissues, such as the ovaries, special protective measures may be taken, such as the use of specific protective pads or barriers, and the use of low-temperature or low-power electrocoagulation modes to reduce potential damage to ovarian function.


Through these techniques and steps, tissue cutting and coagulation during laparoscopic surgery are completed efficiently and safely, while maximizing the protection of the patient's health and organ function.


For more photos and details please contact me:
Company Name: Tonglu Wanhe Medical Instruments Co., Ltd.
Sales: Aiden


Quality ISO13485 Certified Steel Laparoscope Instruments Titanium Clip Applicator for Medical for sale
Send your message to this supplier
 
*From:
*To: Tonglu Wanhe Medical Instrument Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0