| Sign In | Join Free | My futurenowinc.com |
|
| Categories | Oil Testing Equipment |
|---|---|
| Brand Name: | LAB TECH |
| Model Number: | AAS |
| Certification: | ISO9001 |
| Place of Origin: | China |
| MOQ: | 1 set Atomic Absorption Spectrophotometer in one order |
| Price: | Negotiable |
| Payment Terms: | Western Union, T/T, L/C |
| Supply Ability: | 100 sets each month |
| Delivery Time: | 3-10 days |
| Packaging Details: | Atomic Absorption Spectrophotometer packed in veneer case. |
| Description: | 8 Lamps Automatic Flame Method Atomic Absorption Spectrophotometer |
| Function: | Measure concentration of elements in samples |
| Features: | Safe, reliable and convenient flame system |
| Wavelength range: | 190 – 900nm |
| Spectral bandwidth: | 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm |
| Lamp stand: | 8 lamps |
| Highest temperature: | 3000℃ |
| Grating: | 1800 lines/mm |
| Control method: | Computer control |
| Dimension: | 700mm×550mm×450mm |
| Weight: | 75kg |
| Company Info. |
| Delta Technology (Chongqing) Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
8 Lamps Automatic Flame Method Atomic Absorption Spectrophotometer
Features:
Instrument Configuration:
Specifications:
Wavelength range | 190 – 900nm |
Spectral bandwidth | Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm |
Accuracy of the wavelength | ±0.15nm |
Receptivity of the wavelength | ≤0.04nm |
Base line stability | ≤0.002A/30min (Cu) |
Characteristic viscosity | 0.02μg/ml/1% (Cu) |
Checking limit | 0.004μg/ml (Cu) |
Preciseness | 0.5% |
Grating | 1800 lines/mm |
Inflamer | All-metal titanium burner |
Atomizer | Effective glass atomizer |
Lamp stand | Eight lamps |
D2 background correction ability | When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method |
Size and weight | 700mm×550mm×450mm 75Kg |
Power source | 220V±22V AC |
Flame System:
Acetylene air burner | 100mm |
Nitrous oxide acetylene flame head | 50mm |
Ignition dynamic baseline drift | ≤0.006A/30min |
(Cu) Characteristic viscosity | ≤0.025μg/ml/1% |
Related standard deviation of the accuracy | ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) |
Safety system | Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner |
Graphite Furnace:
The highest temperature | 3000℃ |
The largest temperature rising speed | ≥2000℃/S |
Characteristic quantity | Cd≤0.5×10-12g Cu≤0.5×10-11g |
Accuracy | Cu≤3% Cd≤3% |
Size and weight | 550mm×450mm×300mm 65Kg |
Safety system | Over current protection |
Protection | Low air pressure alarm, low cooling water flow alarm |
Power source and power | 220V±22V AC 7000W |



|