| Sign In | Join Free | My futurenowinc.com | 
              
  | 
      
| Categories | Fire Testing Equipment | 
|---|---|
| Brand Name: | LAB TECH | 
| Model Number: | FRP | 
| Certification: | ISO9001 | 
| Place of Origin: | China | 
| MOQ: | 1 set Flooring Radiant Panel Tester | 
| Price: | USD1.0 | 
| Payment Terms: | T/T, Western Union | 
| Supply Ability: | 10 sets per month | 
| Delivery Time: | 45 days | 
| Packaging Details: | Flooring Radiant Panel Tester packed in veneer case | 
| Item Name: | RFP EN ISO9239-1 Lab Testing Equipment Building Material Flooring Radiant Panel Tester | 
| Function: | For flooring materials reaction to fire testing, Building Material Flooring Radiant Panel Tester | 
| Application field: | Building material | 
| Reference standards: | ASTM E648 | 
| Dimension: | 1900mm (W) x 750mm x (H) x 2120mm (D) | 
| Weight: | 235kg | 
| Packing mode: | Veneer case | 
| Warranty period: | 1 year | 
| Service: | Installation and commissioning service is available | 
| Company Info. | 
| Delta Technology (Chongqing) Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
The ISO 9239-1 Building Material Flooring Radiant Panel Tester is the cornerstone of the flooring materials reaction to fire tests in the Euroclass system.
ISO 9239-1 Building Material Flooring Radiant Panel Tester measures the spread of flame of the sample, under thermal exposure, using a radiant heat ignition source. The thermal exposure is that of a fire growing in the room of origin that through a door opening, radiates onto the floorings in an adjacent room or corridor.
FRP ISO 9239-1 Building Material Flooring Radiant Panel Tester can also be used for tests to standards ASTM E648 and DIN 4102; Part 14.
ISO 9239-1: Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source;
ASTM E648- 17: Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source;
Building Materials;
Rail;
Automotive interior;
Others;
The resulting test chamber is insulated with calcium silicate insulation board and is provided with a temperature resistant observation window.
The stainless steel sample support assembly is mounted on a sliding platform to allow safe and easy loading of the test sample.
The radiant heat is applied by means of a gas-fuelled panel, inclined at 30º, and directed at a horizontally mounted floor covering system specimen.
The radiant panel generates a radiant energy flux distribution ranging from a nominal maximum of 10.9 kW/m2 to a minimum of 1.1 kW/m2.
Dummy calibration specimen with holder, calibrated heat flux meter and mounting.
The distance burned until flame-out is reached and converted, by calibration, into an equivalent critical radiant flux, in kW/m2.
Heat Flux Meter: Range 0 ~ 50 kw/m2; Surface emissivity: ε=0.95± 0.05
A smoke measuring system, according to DIN 50055, is mounted on a separate frame at the exhaust stack.
Control Rack for convenience in use, allowing observation of the apparatus and controls during equipment set-up and calibration.
Automatic ignition of the radiant panel and safety cut-out.
Automatic moving T type ignition burner
Stainless steel hood with smoke measurement ports.
No.  | Item Name  | ISO 9239-1 Building Material Flooring Radiant Panel Tester  | 
1  | Dimension  | 1900mm (W) x 750mm x (H) x 2120mm (D)  | 
2  | Weight  | 235kg  | 
3  | Power supply  | 230 volts Nominal 10 Amps  | 
4  | Ambient temperature  | Operating 10oC to 35oC  | 
5  | Burning gas  | Propane  | 
6  | Auxiliary gas  | Air compressor gas  | 


                                 
                             |