| Sign In | Join Free | My futurenowinc.com | 
 | 
| Categories | Residual Current Device | 
|---|---|
| Brand Name: | HAROK | 
| Model Number: | VKL11 | 
| Place of Origin: | CHINA | 
| Certification: | NF, SEMKO, VDE, KEMA, ISI, CE | 
| MOQ: | 1000 | 
| Packaging Details: | PAPER CARTON | 
| Delivery Time: | 4-6 weeks after payment | 
| Supply Ability: | 100,000 PCS PER MONTH | 
| Rated Residual Operating Time: | 0.1s | 
| Rated Impulse Withstand Voltage: | 4kV | 
| Rated Frequency: | 50/60Hz | 
| Rated Voltage: | 240/415V AC | 
| Protection Class: | IP20 | 
| Rated Operating Temperature: | -25℃~+40℃ | 
| Rated Current: | 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A | 
| Rated Residual Non-Operating Time: | 5s | 
| Company Info. | 
| Yueqing Vorax Electric CO.,LTD | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
VKL11 Residual Current Device (RCD) TYPE F
1. General
1.1 Function
VKL11F Residual Current Circuit Breaker Type F(RCCB Type F) is appearance design, compact structure,good reliability, and high safety.
The VKL11F RCCB Type F is defined according to IEC/EN 62423. It provides safe and reliable protection against sinusoidal residual currents and pulsating DC fault currents (like type A devices). It is also capable of handling residual currents with mixed frequencies of up to 1 kHz (10, 50, 1000 Hz) in accordance with the IEC 62423 standard. Type F RCCB maintain the standard functionality with superimposed smooth DC residual currents of up to 10 mA without affecting their standard functionality(However, smooth DC fault currents cannot be detected).
VKL11F RCCB Type F have additionally short-time delayed compared to RCCB Type A, and distinguish themselves from other devices thanks to their high resistance to power surges(have an increased surge current resistance of 3,000 A, prevent unwanted trippings e. g. due to surge currents, thunderstorms or operational leakage currents and thus increase system availability): this ensures minimal false tripping and a high degree of safety. They are available as RCCBs (2-pole or 4-pole up to 100 A) . With three versions for different residual currents (30mA,100mA and 300 mA), the RCCB type F functionality is voltage independent and can be used for fault and additional protection.
Note:Washing machines, hoovers, dishwashers, vibrators, hammer drills, heating and heat pumps, ballasts in lighting systems, air conditioners and welding equipment are all appliances that are in daily use in industry and households. As electronic controllers are increasingly used in such devices, residual currents occur that cannot be adequately detected by a type A RCCB. The reason for this is obvious: single-phase frequency converters are being used more and more frequently to control the motor speed in order to make the devices more energy efficient. These frequency inverters can generate residual currents with mixing frequencies other than 50 Hz by outputting a variable frequency in the order of 10 to 400 Hz. As a result, a RCCB Type A may not trip properly in the event of a fault, because it is affected by these mixing frequencies. This would mean that the RCCB will not possibly trip even if a fault occurs in the 50 Hz range.
Residual current circuit breaker VKL11F Type F solve all above problems!
Advantage:
• Suitable for use with single-phase frequency inverters
• Sensitive to alternating and pulsating DC fault currents of the mains frequency (Type A)
• Meets all requirements for RCCBs Type A, so that this can be replaced 1:1 by Type F
• Functionality maintenance with superimposed smooth DC residual currents of up to 10 mA (instead of only 6 mA, as with Type A)
• Sensitive to alternating residual currents with mixing frequencies unequal to 50 Hz (up to 1 kHz)
• High immunity against surge fault currents and mains voltage driven follow-on current pulses up to 3 kA
• Short-time delay of up to 10 ms prevents unwanted triggering by transient leakage currents
• Thunderstorm proof
• Small size for all rated currents
• High short-circuit current resistance of 10 kA
1.2 Selection
Detectable wave form
Type F 
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, maintain the standard functionality with superimposed smooth DC residual currents of up to 10 mA



Tripping sensitivity
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide
protection against indirect contacts;
300mA - protection against indirect contacts, as well as fire hazard.
Tripping time
Short time delay
3. Outline and installation dimensions (mm)

Residual Current Device (RCD) Type F is an important electrical safety device which is used to protect people from electric shock. It monitors the electric current flowing in the circuit and opens the circuit if the current exceeds a set value. RCD Type F has a rated current of 30mA and a protection class of IP20. It is certified by Inmetro, an international certification body for electrical safety products.
Residual Current Device (RCD) is a device designed to protect people and property from electric shock by automatically disconnecting the power supply in the event of an electric leakage. HAROK's Residual Current Device Type VKL11 is a reliable and safe device for household and commercial application. It is certified by NF, SEMKO, VDE, KEMA, ISI and CE, and it meets the highest safety standards. The Protection Class is IP20, making it suitable to use in a variety of environments. The Minimum Order Quantity is 1000, and the packaging is in Paper Carton. Delivery time is 4-6 weeks after payment, and the Supply Ability is 100,000 PCS PER MONTH.
Brand Name: HAROK
Model Number: VKL11
Place of Origin: CHINA
Certification: NF, SEMKO, VDE, KEMA, ISI, CE
Minimum Order Quantity: 1000
Packaging Details: PAPER CARTON
Delivery Time: 4-6 weeks after payment
Supply Ability: 100,000 PCS PER MONTH
Rated Residual Operating Current: 30mA, 100mA, 300mA
Rated Insulation Voltage: 500V
Rated Impact Endurance Voltage: 2kV
Rated Short-Circuit Capacity: 10kA
The Residual Current Device (RCD) should be packaged and shipped following the steps below:
|   | 
 VKL11 ISI Mark Residual Current Device RCD
                                                                                        
                                                        
                        
                        
                        
                                                            VKL11 ISI Mark Residual Current Device RCD
                                                    
                        
                     VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD
                                                                                        
                                                        
                        
                        
                        
                                                            VKL11 240/415V AC Type A Type AC Type ASi Residual Current Device RCD
                                                    
                        
                     VKL11 Certified NF Residual Current Device Type EV  Rcd
                                                                                        
                                                        
                        
                        
                        
                                                            VKL11 Certified NF Residual Current Device Type EV  Rcd
                                                    
                        
                     UL1053 Rated Residual Current Device ISI Certificate Non Operating Time 5s
                                                                                        
                                                        
                        
                        
                        
                                                            UL1053 Rated Residual Current Device ISI Certificate Non Operating Time 5s
                                                    
                        
                     VFL001 Residual Current Device RCD Type AC Type A Type ASi 10kA 4kV Rated Short Circuit Capacity
                                                                                        
                                                        
                        
                        
                        
                                                            VFL001 Residual Current Device RCD Type AC Type A Type ASi 10kA 4kV Rated Short Circuit Capacity
                                                    
                        
                     Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage
                                                                                        
                                                        
                        
                        
                        
                                                            Residual Current Device Type G IP20 Protection Class 240/415V AC Rated Voltage
                                                    
                        
                     VKL11 Residual Current Device RCD Type S Selective Time Delay
                                                                                        
                                                        
                        
                        
                        
                                                            VKL11 Residual Current Device RCD Type S Selective Time Delay
                                                    
                        
                     VKL11 Residual Current Device RCD WITH NF SEMKO VDE KEMA
                                                                                        
                                                        
                        
                        
                        
                                                            VKL11 Residual Current Device RCD WITH NF SEMKO VDE KEMA
                                                    
                        
                     VML01 Residual Current Device RCD Inmetro Certified- Rated  Rated Frequency 50/60Hz
                                                                                        
                                                        
                        
                        
                        
                                                            VML01 Residual Current Device RCD Inmetro Certified- Rated  Rated Frequency 50/60Hz
                                                    
                        
                     VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate
                                                                                        
                                                        
                        
                        
                        
                                                            VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate