| Sign In | Join Free | My futurenowinc.com |
|
| Categories | VICTOR Digital Multimeter |
|---|---|
| Brand Name: | VICTOR |
| Model Number: | VICTOR 189A |
| Certification: | CE |
| Place of Origin: | CHINA |
| MOQ: | 1pcs |
| Price: | USD185/pc |
| Payment Terms: | T/T, Western Union, L/C, Paypal |
| Supply Ability: | 1000pcs available |
| Delivery Time: | 5 to 30 days |
| Packaging Details: | 10pcs/Carton; Carton Size: 39.5*38.5*26cm; 11.2KG/carton |
| Color: | Blue and Black |
| Size: | 206*97*60mm |
| Product Name: | Multi-function True RMS Multimeter |
| Model No.: | VICTOR 189A |
| Material: | Plastic, metal, silica gel |
| Packing Details: | 10pcs/Carton; Carton Size: 39.5*38.5*26cm |
| Accuracy: | 0.025% accuracy |
| Warranty: | 1 year |
| Weight: | Approx. 500 g (including batteries) |
| Display: | 55000 words |
0.025% Accuracy 55000 Counts VICTOR Digital Multimeter 1000V Fuse Protection
VICTOR189A 0.025% Accuracy True RMS Multi-function Digital Multimeter With 55000 counts Display 1000V Fuse Protection With USB
Basic feature
AC voltage, DC voltage, AC current, resistance, capacity
Continuity, diode, frequency/duty ratio measurement
temperature measurement, RTD measurement, peak measurement(PEAK)
AC + frequency(AC+Hz)measurement
relative measurement(REL_%)
maximum value, minimum value, average measurement(MAX/MIN/AVG)
| Project | VICTOR 189A | |
| DC voltage | Range | 50mV/500mV/5V/50V/500V/1000V |
| Basic accuracy | ±(0.025%+5dgt) | |
| AC voltage | Range | 50mV/500mV/5V/50V/500V/1000V |
| Basic accuracy | ±(0.7%+30dgt) | |
| DC current | Range | 500uA/2000uA/20mA/200mA/2A/10A |
| Basic accuracy | ±(0.15%+10dgt) | |
| AC current | Range | 500uA/2000uA/20mA/200mA/2A/10A |
| Basic accuracy | ±(0.8%+30dgt) | |
| Resistance | Range | 50Ω/500Ω/5kΩ/50kΩ/500kΩ/5MΩ/50MΩ |
| Basic accuracy | ±(0.05%+5dgt) | |
| Capacitance | Range | 10nF/100nF/1000nF/10uF/100uF /1000uF/10mF/100mF |
| Basic accuracy | ±(5%+5dgt) | |
| Frequency | Range | 10Hz~100KHz |
| Basic accuracy | ±(0.02%+4dgt) | |
| Thermocouple | Range | K indexing:-200.0°C~1360.0°C |
| Basic accuracy | ±(0.5%+3°C) | |
| RTD | Range | Pt100:-200.0°C~800.0°C |
| Basic accuracy | ±(0.5%+3°C) | |
| Display words | 55000 | |
| The measurement rate | Fast:20 times / sec Slow:5 times / sec | |
| Analog Bar graph | The faster rate:20 times / sec | |
| Automatic / manual range | √ | |
| Measure the true effective value | √ | |
| Bandwidth | 50kHz | |
| The duty ratio | 10%~90% | |
| Diode test | √ | |
| Continuity beeper | √ | |
| dBm | √ | |
| Low pass filter | √ | |
| MAX/MIN/AVG | √ | |
| Relative value measurement | √ | |
| Data Hold | √ | |
| Auto Hold | √ | |
| Peak Hold | √ | |
| The reference junction compensation | √ | |
| °C/ ° F conversion | √ | |
| Change rate | √ | |
| Input impedance | 10MΩ | |
| Data recording | Manual record:1000 groups Homework:1000 groups of records | |
| Online communication | VICTOR 189A can undertake wired communication with intrared serial port of the compatible USB connection. | |
| Support the SCPI command, can realize remote control instrument by the device driver software. The powerful function, friendly man-machine interface, the user can conveniently obtain multiple data parameters of instrument, and the data storage, processing, management, access to data is displayed in the graphical or tabular form. | ||
| Auto power-off | √ | |
| Display type | LCD | |
| Backlight | √ | |
| Power Supply | 4×AA Alkaline batteries | |
| Safety | CAT IV 600V,CAT III 1000V | |
| Electromagnetic compatibility | IEC61326-1,Group1,Class B | |
| Size | 206×97×60mm | |
| Weight | About500g | |
| Standard Quantity Per Carton | 10pcs | |
| Standard Carton Measurement | 395mm*385mm*260mm | |
| Standard Carton Cross Weight | 11.3Kg | |
Technique indicators
| measurement function | range | measurement range | resolution | accuracy | remark | |||||
20Hz~ 45Hz | 45Hz~ 65Hz | 65Hz~ 1KHz | 1KHz~ 10KHz | 10KHz~ 20KHz | 20KHz~ 50KHz | |||||
AC voltage ACV | 5V | 0~5.5000V | 0.0001V | 2%+80 | 0.5%+30 | 0.7%+30 | 2%+30 | 3%+60 | 5%+100 | Input impedance 10MΩ / 50pF Response time≤2S |
| 50V | 0~55.000V | 0.001V | 2%+80 | 0.5%+30 | 0.7%+30 | 2%+30 | 3%+60 | 5%+100 | ||
| 500V | 0~550.00V | 0.01V | 2%+80 | 0.5%+30 | 0.7%+30 | ----- | ----- | ----- | ||
| 1000V | 0~760.0V | 0.1V | 2%+80 | 0.5%+30 | 0.7%+30 | ----- | ----- | ----- | ||
AC mili-voltage ACmV | 50mV | 0~55.000mV | 0.001mV | 2%+80 | 0.7%+30 | 0.7%+30 | 2%+30 | 3%+60 | 5%+100 | |
| 500mV | 0~550.00mV | 0.01mV | 2%+80 | 0.7%+30 | 0.7%+30 | 2%+30 | 3%+60 | 5%+100 | ||
AC current ACA | 10A | 0~10.000A | 0.001 A | 2%+40 | 1.5%+20 | 3%+80 | ----- | ----- | Voltage Drop <0.1 V/A Response time≤3S | |
| 5A | 0~5.5000A | 0.0001 A | 2%+40 | 1%+20 | 3%+80 | ----- | ----- | |||
AC mili-current ACmA | 50mA | 0~55.000mA | 0.001mA | 1.5%+80 | 0.5%+30 | 1%+30 | 2%+60 | ----- | Voltage Drop <4 mV/mA Response time≤3S | |
| 500mA | 0~500.00mA | 0.01 mA | 1.5%+80 | 0.5%+30 | 1%+30 | 2%+60 | ----- | |||
AC micro-current ACuA | 500uA | 0~550.00uA | 0.01uA | 1.5%+80 | 0.5%+30 | 1%+30 | 2%+60 | ----- | Voltage Drop 0.11 mVuA Response time≤3S | |
| 5000uA | 0~5500.0uA | 0.1uA | 1.5%+80 | 0.5%+30 | 1%+30 | 2%+60 | ----- | |||
| ULF | 2%+100 | 2%+60 (4) -6%-80 | ----- | ----- | ||||||
Note : ① <20kHz adapts to 5~110% range,≥20kHz adapts to 10~110% range.
② 50mV,500mV,1000V range adapt to 10~110% range.










|