| Sign In | Join Free | My futurenowinc.com |
|
| Categories | Electrical Appliance Testing Equipment |
|---|---|
| Brand Name: | Sinuo |
| Model Number: | SN1104 |
| Certification: | Calibration Certificate (Cost Additional) |
| Place of Origin: | China |
| MOQ: | 1 |
| Price: | Negotiable |
| Payment Terms: | T/T |
| Supply Ability: | 30 sets per month |
| Delivery Time: | 20 Days |
| Packaging Details: | Carton |
| Output Voltage: | 12.5kV (Max)±5% |
| Peak Voltage: | 300 V~ 12,500V |
| Impulse Wavefront Time: | 1.2 µs ± 30 % |
| Half Value of after Wave Time: | 50 µs ± 20 % |
| Impact Interval Time: | 5 ~ 99s |
| Impact Cycles: | 1 ~ 9999 |
| Polarity: | Positive and negative |
| Resistance Converter: | 500Ω - 10% |
| Company Info. |
| Sinuo Testing Equipment Co. , Limited |
| Verified Supplier |
| View Contact Details |
| Product List |
IEC 60335-1 Impulse Voltage Generator For Household Appliance Max 12.5kV
Product Information For Impulse Voltage Generator:
Standard: Conforms to IEC60335-1 clause 14, IEC60065:2014 clause
10.2, 13.3.4 a), and IEC 60065:2014 clause 13.3.4 b), 14.2,
IEC60950, etc.
Application: It is used to detect the transient over voltage of the
components and the electrical clearance and the creepage distance.
Test sample: Household appliance, Audio, video, and similar
electronic apparatus.
Feature: The sample breakdown will produce a spark and acoustic,
instrument peak voltage than the no-load voltage is decreased
substantially (close to zero), when applying the same voltage in
the next test, it will also show the above phenomenon.

Technical Parameters For Impulse Voltage Generator:
| Model | SN1104 |
| DC high voltage | Max. 12.5kV |
| Impulse voltage wave | Impulse wavefront time: 1.2 µs ± 30 %; Half value of after wave time: 50 µs ± 20 % Note: the waveform can be checked by connecting an external oscilloscope |
| Instrument internal resistance | 12Ω ± 10% |
| Internal resistance converter box | 500Ω - 10% is optional |
| Peak voltage: 300 V~ 12,500V | 300-12500V Low: 300 V~ 2,500V; High: 2,500 V~ 12,500V |
| Impact interval time | 5 ~ 99s |
| Impact cycles | 1 ~ 9999 |
| Polarity | Positive and negative |
| Working power source | Rated voltage: ~ 220V±10%, 60Hz |
| Dimension | 430mm×180mm×480mm |
| Weight | 20 KG |


|