| Sign In | Join Free | My futurenowinc.com |
|
| Categories | Switch Life Tester |
|---|---|
| Brand Name: | Sinuo |
| Model Number: | SN2212 |
| Certification: | Calibration Certificate (Cost Additional) |
| Place of Origin: | China |
| MOQ: | 1 |
| Price: | Negotiable |
| Payment Terms: | T/T |
| Supply Ability: | 15 Sets Per Month |
| Delivery Time: | 30 Days |
| Packaging Details: | Plywood Case |
| Capacity: | 5KVA |
| Accuracy: | 1.5% |
| Output frequency: | 50/60Hz |
| Output waveform: | Sine wave |
| Test range: | 1~300s |
| Test step: | 1s/step |
| Output voltage setting range: | AC 200~5000V |
| Output voltage accuracy: | ±(1.5%×setting+5words) |
| Company Info. |
| Sinuo Testing Equipment Co. , Limited |
| Verified Supplier |
| View Contact Details |
| Product List |
IEC 60335-1 5KVA Multimeter Electrical Safety Tester With 6 Functions
Product Information For Multimeter Electrical Safety Tester:
This multitester electrical safety tester Conforms to IEC 60598-1 clause 8.2.3, clause10.2.1, clause 10.2.2, IEC 60950:2013 clause 2.6.3.4, 5.2 and 6.2.2.3, IEC 60335-1 Clause 13, Clause 16, Clause 27 and etc. It integrates 6 functions of hi-pot, insulation, grounding, leakage, power, low-voltage start testing.
Features For Multimeter Electrical Safety Tester:
■Meet CCC, IEC, EN, VDE, BS, GS, UL and other electrical safety standards
■Unlimited storage of test conditions and test results
■Data can be copied via USB
■Fast speed: ARM high-speed processor is used as the control core of the test instrument, and data processing is comprehensive and fast
■High accuracy: safety test accuracy up to 1.5%
■Ramp rise and down of voltage withstand can be set, and with upper and lower limit alarm function
■Digital closed-loop feedback control mode, fully automatic voltage regulation mode, output voltage / current is automatically corrected, and it is not affected by external power grid fluctuations to ensure the accuracy of the test
■Two judgment modes can be chosen for ground resistance test: voltage and resistance, to meet the requirements of different national / industry standards
■Built-in one human body network fora leakage current test, which can be customized to any human body network-optional function
Technical Parameters For Multimeter Electrical Safety Tester:
| Model | Functions | Capacity | Accuracy | |
| SN2212 | ACW/IR/GB/LC/PWR/STR | Built-in Frequency Power Supply, 5KVA | 1.5% | |
| AC withstand voltage | ||||
| Output voltage setting range | AC 200~5000V | |||
| Output voltage accuracy | ±(1.5%×setting+5words) | |||
| Output voltage setting step | 1V | |||
| Output frequency | 50/60Hz | |||
Output waveform | Sine wave | |||
| Distortion of output waveform | Less than 2% (at purely resistive load) | |||
| Output waveform adjustment rate | Less than(2%* setting +5V) | |||
| Output capacity | 500VA | |||
| Output voltage ramp-down time setting range | 0~300s | |||
| Set step | 0.1s | |||
| Breakdown current measurement range | 0.10~99.99mA | |||
| Breakdown current test accuracy | ±(1.5%×reading+5words) | |||
| Breakdown current preset upper limit | 0.10~99.99mA | |||
| Breakdown current preset lower limit | 0.00~5.00mA | |||
| Breakdown current preset step | 0.01mA/step | |||
| Test time setting range | 1~300s | |||
| Test time setting step | 1s/step | |||
| Arc detection | 1~9 Level (level 9 is the highest sensitivity) | |||
| Insulation resistance | ||||
| Output voltage setting range | DC 200~1000V | |||
| Output voltage accuracy | ± (1.5%×reading+5 words) | |||
| Output voltage setting step | 1V | |||
| Output capacity | 60VA | |||
Output voltage ramp-down time setting range | 0~300s | |||
| Set step | 0.1s | |||
| Insulation resistance measurement range / accuracy | 1~2000 MΩ ≤100 MΩ:±(5%×displaying+3words) >100 MΩ:±(8%×displaying+8words) | |||
| Insulation resistance alarm setting range | Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ | |||
| Test time range, resolution | 1~300s 1s/step | |||
| Ground resistance | ||||
| Ground current output range / accuracy | AC 5.0~30.0A | |||
| Ground current accuracy | ±(1.5%×setting+0.2A) | |||
| Ground resistance measurement range | 10.0~600mΩ | |||
| Ground resistance measurement accuracy | ±(1.5%×displaying+3mΩ) | |||
| Ground resistance alarm setting range | Upper limit: 5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ; lower limit:0.0~100mΩ | |||
| Ground resistance setting step | 1mΩ | |||
| Test time range | 1~300s | |||
| Test time step | 1s/step | |||
| Leakage current | ||||
| The output voltage | 1.06 times rated voltage provided by the built-in variable frequency power supply | |||
| Leak type setting | Dynamic leakage, static leakage, built-in one leakage current human body network, any human body network can be customized | |||
| Output voltage measurement range | AC 50~280V | |||
| Output voltage frequency | AC 45~65Hz | |||
| Output voltage accuracy | ±(0.5%×displaying+2words) | |||
| Leakage current measurement range | 0.05~20.00mA | |||
| Leakage current measurement accuracy | ± (1.5%× displaying +10uA) | |||
| Leakage current setting alarm range | Upper limit: 0.05 ~ 20.00mA; lower limit: 0.01 ~ 5.00mA | |||
| Leakage current setting step | 0.01mA | |||
| Test time range | 1~300s 1s/step | |||
| Power | ||||
| Output voltage | 1.0 times rated voltage, provided by built-in variable frequency power supply | |||
| Output voltage measurement range / accuracy | AC 50~280V ±(0.5%×displaying+2 words) | |||
| Output current measurement range / accuracy | AC 0.20~30.00A ±(0.5%× displaying +2 words ) | |||
| Active power measurement range / accuracy | 30~6000W ±(0.5%× displaying +5 words ) | |||
| Power setting alarm range | Upper limit: 3 ~ 6000W , Lower limit: 0 ~ 6000W | |||
| Test time range / resolution | 1~300s 1s/step | |||
| Low voltage start | ||||
| Output voltage | 0.85 times rated voltage provided by the built-in variable frequency power supply | |||
| Output voltage measurement range / accuracy | AC 50~280V ±(0.5%× displaying +2words) | |||
| Starting current measurement range / accuracy | AC 0.20~30.00A ±(0.5%× displaying +2 words ) | |||
| Current setting alarm range | Upper limit:0.20~30.00A Lower limit: 0.00~25.00A | |||
| Test time range | 1~300s 1s/step | |||
| Communication Interface | 232 485 can Bus TCP / IP interface | |||
| External control method | PLC interface, switch signal | |||
| System appearance | Size:600W*1840H*600Dmm Height with pulley, alarm light | |||
| System standard accessories | Power cord × 1, foot switch × 1, 30A test clamp × 1, test box × 1, power input line × 1, fuse tube × 1 | |||


|