| Sign In | Join Free | My futurenowinc.com | 
 | 
| Categories | Walk In Environmental Test Chamber | 
|---|---|
| Brand Name: | Sinuo | 
| Model Number: | SN886 | 
| Certification: | Calibration Certificate (Cost Additional) | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Payment Terms: | T/T | 
| Delivery Time: | 45 days | 
| Price: | Customized | 
| Supply Ability: | 10 sets/month | 
| Packaging Details: | Other | 
| Applied Standard: | IEC60068 series | 
| Effective Volume: | Can be customized | 
| Temperature Range: | Can be customized | 
| Temperature Variation: | ±2℃ | 
| Humidity Range: | 30%〜98%RH | 
| Humidity Variation: | ±5.0%RH | 
| Heating Rate: | ≥2.5°C/min | 
| Cooling Rate: | Average 1.0℃/min | 
| Company Info. | 
| Sinuo Testing Equipment Co. , Limited | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
IEC 60068 Temperature Humidity Walk In Environmental Test Chambers
Complied Standards & Clauses
IEC 60068-2-1:2007 “Environmental Testing-Part 2-1: Tests-Test A: Cold, IDT”
IEC 60068-2-2:2007 “Environmental Testing-Part 2-1: Tests- Test B-Dry heat, IDT”
IEC 60068-2-14:1984 "Basic environmental testing procedures-Part 2: Tests-Test N: Change of temperature, IDT"
IEC 60068-2-30:2005 “Environmental Testing-Part 2-30: Tests-Test Db: Damp heat, cyclic (12h+12h cycle) , IDT”
IEC 60068-2-78:2012 “Environmental Testing-Part 2-78: Tests-Test Cab: Damp heat, steady state, IDT”
IEC 60068-3-1:1974, "Basic environmental testing procedures-Part 3: Background information -Section 1: Cold and dry heat tests"
IEC 60068-3-1A:1978, First supplement to publication 60068-3-1, IDT) and etc.
Equipment Overview
It is used to make the test of high and low temperature, damp and heat tests on electrical, electronic, mechanical and large parts, semi-finished products, and finished products. To test the quality and productivity of products, spare parts under simulated temperature and humidity conditions.
Installation environment:
Temperature: 0℃~35℃, relative humidity: ≤85%, air pressure: 86kPA~106kPa.
Please confirm that the installation site should be level, well ventilated, and without strong vibration around the equipment. There has no strong electromagnetic filed, without flammable, explosive, corrosive substances and dust around this equipment. It should leave enough space for use and maintenance.
Technical Parameters
| Standard volume(m³) | 8 | 12 | 80 | 125 | 
| Internal chamber size (W*H*D) m | 2×2×2 | 3×2×2 | 4×4×5 | 5×2×5 | 
| Temperature range | The highest test temperature: 80℃, 120℃; the lowest test temperature: -60℃, -40℃, -20℃, 0℃ | |||
| Humidity range | 30%~98%RH | |||
| Temperature variation | ±2℃ | |||
| Temperature uniformity | ±2℃ | |||
| Temperature fluctuation | ±0.5℃ | |||
| Humidity variation | ±5.0%RH | |||
| Heating rate | ≥2.5°C/min (Non-linear, no load) | |||
| Cooling rate | Average 1.0℃/min | |||
| Internal chamber material | SUS304 stainless plate | |||
| External chamber material | A3 cold-rolled steel plate with electrostatic double-sided spraying /SUS304 stainless steel | |||
| Insulation material | Rigid polyurethane foam | |||
| Cooling method | Water-cooled (adopt German Bitzer fully enclosed compressor or German Bock semi-hermetic compressor) | |||
| The refrigerant | R404a, R23 | |||
| Temperature and Humidity sensor | A grade PT100 platinum resistance | |||
| Heater | Nickel-chromium alloy electric-heating heater | |||
| Humidifier | Adopt external humidification method | |||
| Power supply | 380V±10%V;50Hz;or match client's local power supply re | |||
| Protection System | Power supply phase loss and phase sequence error protection, water shortage automatic alarm protection, leakage protection, heater over temperature protection, heater short circuit and other overcurrent protection | |||



|   | 
 Constant Temperature Humidity walk in environmental test chamber 13m3 less than 75dB
                                                                                        
                                                        
                        
                        
                        
                                                            Constant Temperature Humidity walk in environmental test chamber 13m3 less than 75dB
                                                    
                        
                     IEC60529 IP5/6X EV Charge Station Walk-In Sand & Dust Test Chamber
                                                                                        
                                                        
                        
                        
                        
                                                            IEC60529 IP5/6X EV Charge Station Walk-In Sand & Dust Test Chamber
                                                    
                        
                     50m³ Walk In Temperature Humidity Environment Stability Test Chamber
                                                                                        
                                                        
                        
                        
                        
                                                            50m³ Walk In Temperature Humidity Environment Stability Test Chamber
                                                    
                        
                     20m³ Walk In Environmental Test Chamber Constant Climate Chamber
                                                                                        
                                                        
                        
                        
                        
                                                            20m³ Walk In Environmental Test Chamber Constant Climate Chamber
                                                    
                        
                     12m³ Constant Temperature and Humidity Walk-In Environmental Chamber
                                                                                        
                                                        
                        
                        
                        
                                                            12m³ Constant Temperature and Humidity Walk-In Environmental Chamber
                                                    
                        
                     27m³ Walk In Environmental Test Chamber Walk-in Temperature Room
                                                                                        
                                                        
                        
                        
                        
                                                            27m³ Walk In Environmental Test Chamber Walk-in Temperature Room
                                                    
                        
                     2880L Programmable Temperature and Humidity Walk In Test Chamber
                                                                                        
                                                        
                        
                        
                        
                                                            2880L Programmable Temperature and Humidity Walk In Test Chamber
                                                    
                        
                     6m³ High Low Temperature Humidity Walk In Environmental Test Chamber
                                                                                        
                                                        
                        
                        
                        
                                                            6m³ High Low Temperature Humidity Walk In Environmental Test Chamber
                                                    
                        
                     Customizable Temperature And Humidity Walk-in Climate Test Chamber
                                                                                        
                                                        
                        
                        
                        
                                                            Customizable Temperature And Humidity Walk-in Climate Test Chamber
                                                    
                        
                     Constant Temperature and Humidity Chamber  20m³ Programmable Climate Chamber
                                                                                        
                                                        
                        
                        
                        
                                                            Constant Temperature and Humidity Chamber  20m³ Programmable Climate Chamber