| Brand Name: | NANBEI |
| Model Number: | GC-MS 3200 |
| Certification: | CE/ISO/SGS/TUV |
| Place of Origin: | China |
| MOQ: | 1/set |
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability: | 500 set/per day |
| Delivery Time: | 7-10days |
| Packaging Details: | Wooden cases and cartons |
| Name: | Gas Chromatograph – Mass Spectrometer (Quadrupole) |
| lPower: | 220 V, 50 Hz |
| Temperature: | 15℃-35℃ |
| Humidity: | 25%-80% RH |
| Column oven temperature: | Room temperature + 10℃-400℃ |
| Temperature stability: | ≤±0.03℃ |
| Maximum heating rate: | 40℃/min |
| Maximum run time: | 999.99 min |
| Company Info. |
| NANBEI INSTRUMENT LIMITED |
| View Contact Details |
| Product List |
Gas Chromatograph – Mass Spectrometer (Quadrupole) with new ion optics system
Brief introduction of NBXD-8010:
Applications
The excellent performance of the GC-MS 3200 makes it suitable for applications in various fields including food safety, environmental safety, chemicals, among others.

1 Detection of Melamine in Milk
The detection limit is stable at 0.01 mg/kg. Linearity remains
excellent between 0.05 - 50 mg/L. Recovery of added standard is
between 85% - 108%. Relative standard deviation is less than 5%.
Correlation coefficient is above 0.999. Results comply with GB / T
22388-2008 standard.
2 Analysis of Volatile Organic Compounds (VOC) in Drinking Water or
Surface Water
Using external standard method, range of linearity is 0.5 - 100
μg/L. Correlation coefficient of each component is between 0.993 ~
0.9992. The lowest detection limit is 0.001 mg/L for vinyl
chloride. The instrument shows excellent performance in VOC
analysis of drinking water in compliance with EPA method 502.2 and
GB5749-2006.
3 Detection of Plasticizer in Liquors
16 types of phthalates in liquor are analyzed simultaneously. Range
of linearity is 0.08 - 1.6 ug/mL. Recovery of added standard is
between 70% - 119%. The lowest detection limit achieved is 1.06
ug/kg for DEP. Shows excellent contamination resistance. After 1
month of continuous use, background signal remains within spec.
4 Trace PAHs Detection
Linear correlation coefficient is more than 0.999 in the
concentration range of 0.05 - 0.5 ug /mL.
Relative standard deviation is less than 6%. The lowest detection
quality for benzopyrazole is 0.05 ng.
5 Detection of Organochlorine Pesticide
In ion monitoring mode, the analysis of organochlorine pesticide provides reliable data. Range of linearity is 0.012 - 0.2 ug/mL. Relative standard deviation is less than 10%. Lowest detection concentration reaches 0.012 ug/L.
6 Rapid Semi-quantitative Analysis of Hydrocarbons
7 Qualitative Analysis of Unknown Samples Using Direct Injection Probe


| Working Conditions | |
| l Power | 220 V, 50 Hz |
| l Temperature | 15℃-35℃ |
| l Humidity | 25%-80% RH |
| Specifications | |
| Gas Chromatograph | |
| l Column oven temperature | Room temperature + 10℃-400℃ |
| l Temperature stability | ≤±0.03℃ |
| Maximum heating rate | 40℃/min |
| Maximum run time | 999.99 min |
| 10-segment programmable temperature control | |
| l Split/splitless inlet (3rd generation EPC) | |
| Maximum temperature: 400℃ | |
| Electronic controlled pressure, flow rate and split ratio | |
| Pressure range: 0-999 kPa | |
| Flow range: 0-200 mL/min | |
| Autosampler (optional) | |
| Mass Spectrometer | |
| l Main Specifications | |
| Mass range | 1.5 - 1024.0 amu |
| Mass stability | Better than 0.1 amu/48 h |
| Resolution | Unit mass |
| Sensitivity | DB-5MS 30m*0.25mm*0.25um fused silica capillary column or similar column. EI source, full scan: (range 100-300 amu). 1 pg OFN S/N≥100:1 |
| Maximum scan rate | 10,000 amu/s |
| Dynamic range | 105 |
| l Ion source | Electron impact ionization source (EI), standard. Chemical ionization source (CI), optional. |
| Dual filaments | Programmable switch |
| Maximum filament current | 3 A |
| Emission current | 10 – 350μA adjustable |
| Ionization energy | 5 – 150eV adjustable |
| Ion source temperature | 150 – 320℃ adjustable, individually controlled |
| l Mass analyzer | Quadrupole. Full scan, selected ion monitoring (SIM) and acquisition. At most 128 groups in SIM mode. At most 128 ions in each group. |
| l Detector | electron multiplier + high-energy dynode back focusing assembly |
| l GC-MS interface | |
| Individually controlled through transmission cable, 150 – 320℃ adjustable | |
| l Vacuum system | |
| Turbo molecular pump (250 L/s), mechanical pump (180 L/min) | |
| Wide range compound cold cathode gauge | |
| l Data processing system | |
| Hardware | Computer (optional) |
| Printer | Laser printer (optional) |
| Software | MS3200RT Real-time data acquisition application and MS3200P data processing application |
Optional Accessories | |
| DIP 100 liquid/solid direct injection probe assembly | |
| Thermal desorption device | |
| Dynamic headspace sampler | |
| Purge-and-trap sample concentrator | |




|