Product Description
The Fuse Cutout are connected with the incoming feeder of the
distribution transformer or distribution lines. These are primary
used to protect transformers or lines from short circuits and
overloads and switching currents. The drop out fuse unit is
composed of insulator supports and a fuse tube, static contacts is
fixed on two sides of insulator support and moving contact is
installed on two ends of fuse tube. The interior of the fuse tube
is the extinguishing tube, the exterior is made of phenolic
compound paper tube or epoxy glass
| Type | Unit | PD-12/100 | PD-12/200 |
| Rated voltage | KV | 10—15 | 10—15 |
| Rated current | A | 100 | 200 |
| Breaking current | A | 10000 | 12000 |
| lmpulse voltage | KV | 110 | 110 |
| Power frequency withstand volatage | KV | 42 | 42 |
| Creepage distance | MM | 250 | 250 |
| Weight | KG | 7 | 7 |
| Dimensions | CM | 38.5×34.5×10.5 | 38.5×34.5×10.5 |
| Type | Unit | PD-15 | PD-15 |
| Rated voltage | KV | 15-27 | 15-27 |
| Rated current | A | 100 | 200 |
| Breaking current | A | 10000 | 12000 |
| lmpulse voltage | KV | 125 | 125 |
| Power frequency withstand volatage | KV | 45 | 45 |
| Creepage distance | MM | 355 | 355 |
| Weight | KG | 8.8 | 8.8 |
| Dimensions | CM | 51.5×34×12 | 51.5×34×12 |
| Type | Unit | PD-24 | PD-24 |
| Rated voltage | KV | 24-27 | 24-27 |
| Rated current | A | 100 | 200 |
| Breaking current | A | 8000 | 10000 |
| lmpulse voltage | KV | 150 | 150 |
| Power frequency withstand volatage | KV | 65 | 65 |
| Creepage distance | MM | 505 | 505 |
| Weight | KG | 12 | 12 |
| Type | Unit | PD-11 | PD-11 |
| Rated voltage | KV | 24 | 24 |
| Rated current | A | 100 | 200 |
| Breaking current | A | 10000 | 12000 |
| lmpulse voltage | KV | 150 | 150 |
| Power frequency withstand volatage | KV | 65 | 65 |
| Creepage distance | MM | 540 | 540 |
| Weight | KG | 4.5 | 4.5 |
| Dimensions | CM | 51×34×11.5 | 51×34×11.5 |
| Type | Unit | PD-12 | PD-12 |
| Rated voltage | KV | 15 | 15 |
| Rated current | A | 100 | 200 |
| Breaking current | A | 10000 | 12000 |
| lmpulse voltage | KV | 110 | 110 |
| Power frequency withstand volatage | KV | 45 | 45 |
| Creepage distance | MM | 245 | 245 |
| Weight | KG | 3.8 | 3.8 |
| Dimensions | CM | 45×34×11.5 | 45×34×11.5 |
| Type | Unit | PD-13 | PD-13 |
| Rated voltage | KV | 33 | 33 |
| Rated current | A | 100 | 200 |
| Breaking current | A | 6000 | 8000 |
| lmpulse voltage | KV | 170 | 170 |
| Power frequency withstand volatage | KV | 70 | 70 |
| Creepage distance | MM | 660 | 660 |
| Weight | KG | 15 | 15 |
| Dimensions | CM | 56×38×11.5 | 56×38×14.5 |
| Type | Unit | PD-36/100 | PD-36/200 |
| Rated voltage | KV | 36 | 36 |
| Rated current | A | 100 | 200 |
| Breaking current | A | 10000 | 12000 |
| lmpulse voltage | KV | 170 | 170 |
| Power frequency withstand volatage | KV | 70 | 70 |
| Creepage distance | MM | 720 | 720 |
| Weight | KG | 5 | 5 |
| Dimensions | CM | 61×34×11.5 | 61×34×11.5 |


Company Information
INTRODUCTION
Zhejiang Xinkou Power Equipment Co.,Ltd, is a high-tech enterprise
specializing in developping, design, manufacture, sales, import and
export of low voltage and high voltage electrical products.
Company main products: indoor and outdoor high voltage vacuum
circuit breaker, load break switches, disconnecting switches, drop
out fuse cutour, lightning arrester, etc. All products comply with
the requirements of GB, IEC, ANSI and other international standard.
SERVICE
We have a very professional sales team which can offer you the best
service and answer you very professional questions, so you can feel
very comfortable before you buy machine from us. As is known to all
of us, after-sale service is the most important to all industries.
Our company has been trying our best to build a very professional
and high-caliber after-sale service team which can solve all
problems efficiently in the future.