| Brand Name: | Sinuo |
| Model Number: | SN1118 |
| Certification: | Calibration Certificate (Cost Additional) |
| Place of Origin: | China |
| MOQ: | 1 |
| Price: | Customized |
| Payment Terms: | L/C, , T/T, Western Union, MoneyGram |
| Supply Ability: | 100 sets per month |
| Delivery Time: | 5 Days |
| Packaging Details: | Plywood |
| Applied Standard: | IEC 60335-2-15 |
| Applied Figure: | Figure 101 |
| Tube Diameter: | 8 mm |
| Tube Length: | 30 mm |
| Solution Volume: | 30 ml |
| Solution Type: | 30ml water containing 1% of NaCl |
| Company Info. |
| Sinuo Testing Equipment Co. , Limited |
| Verified Supplier |
| View Contact Details |
| Product List |
IEC 60335-2-15 Figure 101 Steam Sterilizer Spillage Test Apparatus
Product overview:
The spillage test apparatus is designed and manufactured according to IEC 60335-2-15 clause 15.2 figure 101, and IEC60320-1 clause 14.2 figure B.1.
It is intended for checking the weight of the protective measures against liquid overflow to ensure that the structure of the plug-in connector (cordless electric kettle) is not affected by liquid when it is installed in an alternative voltage base following the manufacturer’s installation instructions.
Technical parameters:
| Tube Diameter | 8 mm |
| Tube Length | 30 mm |
| Test Solution Volume | 30 ml |
| Test Solution Type | 30ml water containing 1% of NaCl |
| Distance from the lower end of tube to the appliance | 200 mm, adjustable |
| Apparatus Material | Plastic |
Steam sterilizers are placed on a horizontal surface and ml of water containing approximately 1% NaCl is poured onto the top rim in the most unfavourable place. The solution is poured steadily through a tube having an inner diameter of 8 mm over a period of 2 s, the lower end of the tube being 200 mm above the appliance.
|