| Port Size: | G3 Inch |
| Media: | Air |
| Power: | Solenoid |
| Structure: | Diaphragm |
| Function: | Normally Closed |
| Action Type: | Pilot Operted |
| Valve Type: | Right Angle |
| Connection Type: | Threaded |
| Price: | Negotiation |
| Company Info. |
| Ningbo Brando Hardware Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
3'' Goyen Type Pneumatic Pulse Valve Right Angle Threaded Type With Aluminum Alloy Body CA76T
CA76T Goyen Type Threaded Valve consist of solenoid coil, armature assembly, diaphragm ,aluminum alloy body and other screws. Pulse valve refers to a diaphragm valve that can be opened and closed by a high pressure gas source in an instant under the control of a pilot valve such as electromagnetic or pneumatic. The pulse valve is the main component of the bag filter, and it can be sprayed more than 1 million times. The pulse valve is based on the airflow through the air resistance,The delay of the air volume makes the long signal input become a pulse signal.
Specification:
| Model No. | CA76T |
| Port Size | G 3 Inch |
| Nornimal Size | Φ76mm |
| Pressure | 0.3~0.8 Mpa |
| Number of Diaphragm | 2 |
| Media | Air |
| Temp | -5℃ ~ 55℃ |
| Relative Humidity | ≤85% |
| Service Life | Over 1000000 times |
| Voltage | DC24V, AC24V, AC110V, AC220V |
Overall Dimension of CA76T solenoid Pulse Valve:

Construction of CA76T Electromagnetic Pulse Valve:

| Part Name | Material |
| Body | Aluminum Alloy (diecast) |
| Ferrule | 305 SS |
| Armature | 430FR SS |
| Seals | Nirtrile or FKM |
| Spring | 304 SS |
| Screws | 302 or 304SS |
| Diaphragm Seat | NBR( common , all available) |
Failure analysis and troubleshooting
1.Does not operate when powered on
1). Poor contact in power wiring → Connect the power cord
2).The power supply voltage is not within the allowable range → the
adjustment voltage is within the normal range
3).Coil shorted or burned out → Replace the coil
2. Fluid cannot pass when opening the valve
1). Fluid viscosity or temperature does not match → adjust pressure
or working pressure difference or replace suitable product
2). Impurities are mixed around the valve core and the moving iron
core → To clean the inside, a filter must be installed before the
valve
3).Pre-valve filter or pilot valve hole blocked → Clean filter or
pilot valve hole in time
4). The operating frequency is too high or the life has expired
during use → change product model or replace with new product
3. The fluid cannot be shut off when the valve is closed
1). Fluid viscosity and temperature do not match → Replace with a
suitable product
2). Deformed or expired spring → Add gasket or replace spring
3). Defective or soiled valve seat → wash, grind, or renew
4. Leakage
1). Loose pipe connection → Tighten bolts or pipe threads
2). Damaged seal at pipe connection → Replace seal
5. Noise is too loud when power is applied
1). Loose fastener → tighten
2). Voltage fluctuation, out of allowable range → adjust to normal
range
3). Unsuitable fluid pressure or working pressure difference →
Adjust pressure or
working pressure difference or replace product
4).Impurities on armature suction surface → Clean in time
Maintenance Kits:
| Nirtrile | FKM | Low Temp–60°C (–76°F) MIN. | Includes |
| K7600 | K7601 | NA | Diaphragm kits include main and secondary diaphragms (where required) and all springs. |
| K0380 | K0384 | NA | O-ring, armature assembly, armature spring, ferrule |