| Sign In | Join Free | My futurenowinc.com | 
 | 
| Categories | Energy Efficiency Lab | 
|---|---|
| Brand Name: | Sinuo | 
| Model Number: | SN331C-60KD | 
| Certification: | Calibration Certificate (Cost Additional) | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | Tailored | 
| Payment Terms: | T/T | 
| Supply Ability: | 1 Set Per Month | 
| Delivery Time: | 3 Months | 
| Packaging Details: | Plywood | 
| Applied Standard: | ISO 5151, ISO 13253 , etc. | 
| UUT: | Air Conditioners & Heat Pumps | 
| Test Stations: | 2 | 
| Control & Operation: | Computer | 
| A Station Cooling Capacity: | 6000~60000Btu/h | 
| B Station Cooling Capacity: | 6000~30000Btu/h | 
| A Station Heating Capacity: | 6000~60000Btu/h | 
| B Station Heating Capacity: | 6000~30000Btu/h | 
| Air Flow A Range: | 300~4000 m³/h | 
| Air Flow B Range: | 200~2000 m³/h | 
| Company Info. | 
| Sinuo Testing Equipment Co. , Limited | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
60K BTU Double Code Air-Enthalpy Method Calorimeter ISO 5151
System introduction:
This air enthalpy method calorimeter lab consists of 1 indoor side room (Room A) and 1 outdoor side room (Room B). The refrigerating capacity, heating capacity and other performances of an air conditioner are tested by means of testing the lab parameters, such as temperature, pressure and electrical performance. This installation can be used to test the performance of various window type, split type, free-standing type and ceiling cassette type and duct type AC air conditioners, and can also be used for other standard operating condition related tests and expanded tests, meeting the need for product sampling inspection and product development. The laboratory is equipped with two stations, which can simultaneously test two sets of 1-Phase prototypes not larger than 30KBtu (to ensure total not large than 60K BTU), if only test one set of prototype once, then prototype can up to 60K BTU, but should not larger than 60K BTU.
In this test system, the operation of the equipment is controlled by a programmable controller and a HMI, test running data are collected by a high accuracy data collector, the data can be transferred at real time to an upper level computer for processing, the computer displays, stores, outputs and prints test reports.
► Rated cooling capacity (T1, T2, T3).
► Rated heating capacity (High, Low, Extra-low)
► Airflow
► Dehumidification capacity
► Input power
► EER(COP)
► Frequency
► Current
► Voltage
► Types of unit under test (UUT)
-Split type
-Window type
-Free-standing type
-Ceiling cassette type
-Duct type
-Inver-frequency air condition
► Measurement range of UUT
-Testing Capacity Range:
-Total Cooling Capacity: 6000~60000Btu/h
A station Cooling Capacity: 6000~60000Btu/h
B station Cooling Capacity: 6000~30000Btu/h
-Heating Capacity: 6000~60000Btu/h
A station Heating Capacity: 6000~60000Btu/h
B station Heating Capacity: 6000~30000Btu/h
-Range of air flow:
-Air Flow A : 300~4000 m³/h
Air Flow B : 200~2000 m³/h
-Figure size:Window Type:W:Under 1000mm D:Under 800mm H:Under 1000mm
Split Type:W:Under 1000mm D:Under 500mm H:Under 2000mm
-The electric parameter:
-Single phase power: 0~5kW
-Single phase voltage: 0~300V
-Single phase current: 0~20A
-Frequency: 50/60Hz
-Power factor: 0~1
| Major test conditions | ||||||
| No | Testing Item | Indoor side(℃) | Outdoor side(℃) | |||
| Dry Bulb | Wet Bulb | Dry Bulb | Wet Bulb | |||
| 1 | Rating Cooling | T1 | 27 | 19 | 35 | 24 | 
| T2 | 21 | 15 | 27 | 19 | ||
| T3 | 29 | 19 | 46 | 24 | ||
| 2 | Maximum Cooling | T1 | 32 | 23 | 48 | 32 | 
| T2 | 27 | 19 | 35 | 24 | ||
| T3 | 32 | 23 | 52 | 31 | ||
| 3 | Freeze-up | T1 | 21 | 15 | 21 | 15 | 
| T2 | 21 | 15 | 10 | 8 | ||
| T3 | 21 | 15 | 21 | 15 | ||
| 4 | Minimum Cooling | 21 | 15 | 18 | 12 | |
| 5 | Enclosure Sweat | 27 | 24 | 27 | 24 | |
| 6 | Rating Heating | High | 20 | 15 | 7 | 6 | 
| Low | 20 | 15 | 2 | 1 | ||
| Extra Low | 10 | 8 | -5 | -6 | ||
| 7 | Maximum Heating | 27 | 19 | 24 | 18 | |
| 8 | Minimum Heating | 20 | 15 | -7 | -8 | |
| 9 | Automatic Defrost | 20 | 12 | 2 | 1 | |
Sinuo is a diversified high-tech enterprise integrating testing equipment, scientific research and teaching equipment, and various non-standard customized equipment, integrating independent R&D and design, production and sales, installation and commissioning, and after-sales maintenance. Our technical staff has accumulated a wealth of practical experience.

|   | 
 IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber
                                                                                    
                        
                        
                        
                                                            IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber
                                                    
                        
                     Performance Analysis Energy Efficiency Lab For Clothes Washing Machines
                                                                                    
                        
                        
                        
                                                            Performance Analysis Energy Efficiency Lab For Clothes Washing Machines
                                                    
                        
                     Energy Efficiency Testing Room For DOE Qualified Ceiling Fans UL Standard Ceiling Fan Laboratory
                                                                                    
                        
                        
                        
                                                            Energy Efficiency Testing Room For DOE Qualified Ceiling Fans UL Standard Ceiling Fan Laboratory
                                                    
                        
                     Temp. 76±2°F Humidity 50% Energy Efficiency Test Lab Of ENERGY STAR Qualified Ceiling Fans
                                                                                    
                        
                        
                        
                                                            Temp. 76±2°F Humidity 50% Energy Efficiency Test Lab Of ENERGY STAR Qualified Ceiling Fans
                                                    
                        
                     Energy Efficiency Testing Laboratory For Electric Water Storage Heaters 4 / 6 / 8/ 10 Stations
                                                                                    
                        
                        
                        
                                                            Energy Efficiency Testing Laboratory For Electric Water Storage Heaters 4 / 6 / 8/ 10 Stations
                                                    
                        
                     Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test
                                                                                        
                                                        
                        
                        
                        
                                                            Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test
                                                    
                        
                     IEC 60456 Washing Machines Performance Testing Room Energy Efficiency Enviromental Lab
                                                                                    
                        
                        
                        
                                                            IEC 60456 Washing Machines Performance Testing Room Energy Efficiency Enviromental Lab
                                                    
                        
                     Electric Rice Cookers Energy Efficiency Lab 2 Test Benches 6 Black Corners
                                                                                    
                        
                        
                        
                                                            Electric Rice Cookers Energy Efficiency Lab 2 Test Benches 6 Black Corners
                                                    
                        
                     Water Efficiency Grades Energy Efficiency Lab For Reverse Osmosis Drinking Water Treatment Purifiers
                                                                                    
                        
                        
                        
                                                            Water Efficiency Grades Energy Efficiency Lab For Reverse Osmosis Drinking Water Treatment Purifiers
                                                    
                        
                     10 ~ 3000m³/H 0~ 200Pa Air Volume Measurement System For A.C. Electric Ventilating Fans
                                                                                    
                        
                        
                        
                                                            10 ~ 3000m³/H 0~ 200Pa Air Volume Measurement System For A.C. Electric Ventilating Fans