Product overview:
This product is a household combustible gas detector (hereinafter
referred to as the alarm), used to detect carbon monoxide gas, the
alarm uses a backlit LCD carbon monoxide concentration display, 3
AA batteries or an external DC5V power supply method, and uses an
electrochemical carbon monoxide sensor. High stability, low power
consumption, and less sensitivity drift. The alarm integrates a
modern intelligent Internet of Things system, which can display
alarm information, fault information, real-time carbon monoxide gas
concentration and other information on the WeChat applet, and send
alarm information to notify users in time when alarming Features.
The meaning of LCD display
| Display content | meaning | shown |
| Err | Sensor failure | Voice prompt "Please pay attention to carbon monoxide sensor failure" |
| CH | Chinese switch successfully | LCD screen displays "CH", indicating that the Chinese switch is successful |
| EN | English switch successfully | LCD screen displays "EN", indicating that the English text is successfully switched |
| End | End of sensor service life | Yellow sensor life indicator, flashing |
| LB | Battery voltage is too low | The yellow fault indicator flashes, and the voice prompts "The battery is too low, please replace the battery" |
Technical parameters
| Model | JM-HYC501-CAT1 |
| Detection gas | CO |
| size | 100*100*42 |
| weight | 200G |
| Power supply | Adapter DC5V / DC4.5V AA |
| stand-by current | 50UA |
| Alarm current | 250MA |
| temperature range | 0~50℃ |
| Humidity range | Maximum 95%RH (no condensation) |
| Alarm sound pressure | ≥85dB/m |
| Alarm Output | Sound and light alarm, remote alarm information push |
| life | 3 years |
| Response time | ≤30S |
| Installation method | Ceiling/wall hanging |
| Working frequency | FDD-LTE: B1, B3, B5, B8, TDD-LTE: B34, B39, B40, B41 GSM/GPRS: 900/1800 MHz |
| communication method | 4G-Cat1 |
| Transmit power | 23dBm+2/-2dB |
| Executive standard | GB15322.2-2019 |