Sign In | Join Free | My futurenowinc.com
futurenowinc.com
Products
Search by Category
Home > Mould Design & Processing Services >

Aluminium RCA15T Pulse Jet Solenoid Valve For Dust Collector

Categories Pulse Jet Valves
Brand Name: FLY, AIRWOLF or others
Model Number: RCA15T
Certification: ISO 9001,CE
Place of Origin: China
MOQ: 1 piece
Price: price negotiable
Payment Terms: T/T in advance,Western Union,Paypal,Credit card
Supply Ability: 2000 pcs/month
Delivery Time: 5 working days
Packaging Details: carton
Power: Pneumatic
Valve body material: Aluminium (diecast)
Pressure: 30-860KPA
Temperature: Normal Temperature
Voltage: AC220V AC110V DC12V DC24V
Company Info.
Airwolf Automation
Verified Supplier
View Contact Details
Product List
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Aluminium RCA15T Pulse Jet Solenoid Valve For Dust Collector

RCA15T remotely piloted G1/2" pilot pulse jet valve for dust collector

Description

High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Construction
Body: Aluminium (diecast)
Ferrule: 304 SS
Armature: 430FR SS
Seals: Nitrile or fluororubber (reinforced)
Spring: 304 SS
Screws: 302 SS
Diaphragm Seat: PA-6 (standard), fluororubber coated mild steel or High Density PE Refer to Q Series Solenoid product data sheet for solenoid construction details.
Maintenance
Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually.
Approvals
Integrally piloted valves meet the requirements of:
. Atex II 2D Mechanical
. CSA (C&US)
C22.2 No. 139-1982 UL Std No. 429
. C-Tick - integral pilots
. EMC (89/336/CE) - integral pilots
Installation
1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
2. Ensure tank and pipes are free from dirt, rust or other particulate.
3. Ensure supply air is clean and dry.
4. Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
6. Apply moderate pressure to system and check for installation leaks.
7. Fully pressurise system.
8. Test fire and listen for proper actuation and crisp pulse noise.

Pressure Range: 30(5)-860(125) kPA(Psi)
Temperature Range: Nitrite Seals: -40°C (-40°F) to 82°C(179.6°F) fluororubber Seals: -29°C (-20.2°F) to 232°C (449.6°F)

Weights:
SizeIntegral Pilot (CA) Kg (lbs)Remote Pilot (RCA) Kg (lbs)SizeIntegral Pilot (CA) Kg (lbs)Remote Pilot (RCA) Kg (lbs)
10NA0.06 (0.14)451.50(3.30)1.28(2.83)
200.60(1.31)0.38 (0.83)502.89(6.38)2.68(5.92)
250.73(1.61)0.51 (1.13)623.31 (7.30)3.09(6.82)
351.04(2.28)0.83 (1.83)764.77(10.52)4.56(10.04)

Maintenance Kits

ModelNitrilefluororubberLow Temperature -60°C (-76°F) Min.Includes
RCA10TK1001K1002NADiaphragm kits include main and secondary diaphragms (where required) and all springs.These kits are for discontinued valves. o-ring, armature assembly, armature spring, ferrule
CA/RCA20TK2000K2007NA
CA/RCA25TK2501K2503K2504
CA/RCA32T*K2500NA
CA/RCA35TK3500K3501K3502
CA/RCA40T*K4000NA
CA/RCA45TK4502K4503K4522
CA/RCA50/62TK5004K5000NA
CA/RCA76TK7600K7601NA
Pilot repair kitK0380K0384NA

CA /RCA Series pulse jet valve , CA Series is solenoid control pulse jet valves, RCA series is air control pulse jet valves


Dimension(mm and inch):


Working principle
Electrical pulse controller send input signals so that the electromagnetic armature attracts the moving bar. Unclose the balancing hole to release the pressure gas in the back cavity of diaphragm quickly; the pressure gas in the front cavity holds up the diaphragm to open the passage and the valve starts cleaning.
The pulse signal disappears and the spring of the armature works immediately to resume the moving bar so as to close the balancing hole. The pressure gas in the back cavity of the diaphragm and the spring work together to close the passage the valve stops cleaning.
The damping hole in the diaphragm functions to damp the airflow when the moving bar of armature holds up for balancing and to transit the air to the back cavity as soon as the balancing hole is shut to close the passage and stop cleaning.


Quality Standards
The company for the products are brand new original products, no second-hand and refurbished products, or leave a compensable ten and return the full amount, but the buyer due to our purchase of model error is not responsible for returns, another of the company's sales of products enjoy one year from the date of shipment quality assurance, according to the original quality standards, during warranty with product problems, need confirmation testing by the manufacturer, the supplier to be solved, the demand side due to storage, use, poor maintenance caused by lower-quality product, and not raise objections.

Quality Aluminium RCA15T Pulse Jet Solenoid Valve For Dust Collector for sale
Send your message to this supplier
 
*From:
*To: Airwolf Automation
*Subject:
*Message:
Characters Remaining: (0/3000)
 