1. Product introduction:
1.1 Product name and model:24kV Pad mounted primary metering cabinet PMY9-24, JLSZXW9-24 combined transformer
1.2 Product overview:
The metering cabinet is for outdoor cabinet type one-piece three-phase primary metering unit , inside has assembled a combination of three independent voltage transformer and current transformer, voltage transformers are made up of three-phase Y-Y star connection, current transformers can be 2pcs or 3pcs optional configuration, cabinet adopts zinc steel, stainless steel or aluminum alloy etc, cabinet surface spraying protection layer resistant to acid and alkali corrosion , prevent the UV irradiation, suitable for outdoor underground cable connected to the public power system. The metering cabinet has installed complete measuring meter box or interval, instrument transformers’ secondary lead all converge in meter box, equipped with test terminal blocks and electric meter installation space, can be configured as required when using electric meter or the user configuration of watt-hour meter can access, suitable for high voltage equipment in urban power distribution network line 24 kV and below for electric energy metering, current and voltage measurements.
1.3 Basic parameters:
| No. | item | units | specification |
Highest voltage for | kV | 24 | |
| rated frequency (fR) | Hz | 50, 60 or 50/60 | |
Rated lightning impulse | kV | 125 ,150 | |
Rated power-frequency | kV | 50 | |
Rated power-frequency | kV | 3 | |
| Number of CTs and VTs | pcs | 3VT+3CT or 2CT+3VT | |
| Standard | / | IEC 61869-1:2007, IEC 61869-2:2012 IEC 61869-3:2011,IEC 61869-4:2013 |
1. The metering cabinet adopts the overall housing-shaped box
design and is divided into three internal compartments, including
medium-voltage cable connection room, medium-voltage instrument
transformer room and metering meter box room. The compact and
beautiful housing design does not affect the greening and
landscape, and the outdoor floor installation is convenient and
quick;
2. The metering unit shall assemble the instrument transformer and
the meter box as a whole, preset the alarm signal of the door
switch sensor, the lock seal and the ingenious door opening and
closing linkage structure. Only after the medium-voltage cable room
is opened, then anti-electricity-stealing design of meter box room
can be opened.
3. The cabinet body is made of corrosion-resistant stainless steel
or low carbon steel of the same performance. It is designed to be
weather-proof, and the surface is coated with anticorrosive paint
powder layer,acid and alkali resistance, UV resistance.
4. The internal MV combined instrument transformer is encapsulated
and poured with epoxy resin solid, the surface is fully screened
and touchable, and can be closely fitted with the external box. The
compact size is only half that of the air insulation metering box,
free of oil and gas and free of maintenance, meeting the
requirements of safe operation and environmental protection;
5. The primary connection adopts separable sealing connection. The
primary connection bushing have two connection types ( 200A bushing
well insert+200A connector and 600A interface bushing+600A
connector) according to standard IEEE STD 386.
| No | Item | Parameters |
| Rated primary current | 5A up to 600A | |
| Rated secondary current | 5A or 1A | |
| Rated Continuous Thermal Current | 120%,125%,150%,200% etc. | |
| Rated Short time current (Ith) (thermal 1 second) | 80xIpr,100xIpr | |
| Rated Dynamic Current (Idyn) | 2.5xIth | |
| Rated Output(VA) | 12.5,15,20 | |
| Accuracy Class | 0.2S,0.2,0.5S,0.5,1 Metering | |
| Instrument Security Factor (FS) | 5,10,20 | |
| Applicable Standard | IEC: 61869-1&2 |
Voltage transformer specifications
| No | Item | Parameters |
| Rated primary voltage(V) | 20000/√3,22000/√3,14400 | |
| Rated secondary voltage(V) | 100/√3,110/√3,110,120,115 | |
| Rated Voltage Factor | 1.2/Continuous 1.5/30s,1.9/30s,1.9/8h | |
| Standard connection | Y-Y(star connection) | |
| Rated Output(VA) | 15,20,25,30,50,75 | |
| Accuracy Class | 0.2,0.5,1,3 Metering | |
| Thermal burden(VA) | 500 | |
| Applicable Standard | IEC: 61869-1&3 |





|