| Brand Name: | TSTLP | 
| Model Number: | SMT-ESE60/LSC3 | 
| Certification: | CE Approval / Test Reports / Patent Right | 
| Place of Origin: | Guangdong, P.R.C. | 
| MOQ: | Negotiable | 
| Price: | Negotiable if good quantity | 
| Packaging Details: | 230x230x450mm colorful box/pc, and 4 pcs in 490x500x500mm carton | 
| Delivery Time: | Around 7 working days upon receipt of payment | 
| Payment Terms: | 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash ahead | 
| Supply Ability: | 1000 pcs/month | 
| Patent Status: | Owned & Normal | 
| Delta T: | 60μs in advance | 
| Metal Housing: | 304 Stainless Steel | 
| Iimp withstanding: | ≥ 200kA | 
| Test Standards: | UNE 21.186:2011 Paragraph C | 
| Testable Or Not: | Yes | 
| Approx Weight: | 4,000g | 
| HS code for lightning conductor: | 8535400000 | 
Oversea tested early streamer emission types of lightning conductors on building



| SMT-ESE60 ESE Types of lightning conductors Operation Principles | |
| Detection of download leader | Continuous measuring of electric field gradient (ΔE/Δt) | 
| Upward streamer development conditions | TSTLP®-SMART Technology optimizing the streamer development conditions | 
| Upward streamer emission | Sparking by High Voltage Impulses | 
| Internal circuits | 6 Independent working unit | 
| Central rod | Full electrical continuity | 
| Enclosure Material | Superior Stainless Steel | 
| On-site testing capabilities | Proprietary E.S.E. types of lightning conductors tester | 
| Yearly Maintenance | Free | 
| Warranty | 10 YEARS | 

Max Radius Protection of SMT-ESE60 early streamer emission lightning conductor :
Level 1: 80m radius protection.
Level 2: 90m radius protection.
Level 3: 105m radius protection.
Level 4: 120m radius protection.
MP4 FLASH of TSTLP ESE Type of Lightning Conductor VS Ordinal Conductor ZONE of PROTECTION, check/download @ https://drive.google.com/file/d/1oluGnqguWksS9eEWPnKvk4PTSCxHQQkh/view?usp=sharing
Additional protection against direct lightning strike for the highest 20% of the structure height for buildings greater than 60 m or any point above 120 m, using ese types of lightning conductor or any other means must be implemented at each façade wall according to a valid standard. Furthermore a minimum of 4 Down conductors, interconnected by a ring conductor when applicable, shall be used, distributed along the perimeter and if possible at each angle of the building.
NOTE: in general the risk due to the lateral flashes is low because only a few percent of all flashes to tall structures will be to the side and moreover their parameters are a lot lower than those of flashes to the top of structures.

Download PDF 2020 TSTLP ESE Lightning Conductor Catalog @ http://www.ese-lightningrod.comhttps://drive.google.com/file/d/1kEW-pWdJdlArVgfrHutq62k9HsVNcHq-/view?usp=sharing