| Sign In | Join Free | My futurenowinc.com | 
 | 
| Categories | AC Resonant Test System | 
|---|---|
| Brand Name: | Fanke High-voltage | 
| Model Number: | CHX-108KVA/27KV,108KV | 
| Certification: | ISO9001 | 
| Place of Origin: | China | 
| MOQ: | One unit | 
| Price: | Negotiable | 
| Payment Terms: | T/T | 
| Supply Ability: | 10units/1months | 
| Delivery Time: | 25-30 Work Days | 
| Packaging Details: | Export Standard Wooden Case With Fumigation Free | 
| Test principle: | Variable frequency resonant circuit | 
| Test Item: | AC withstand voltage test under 108KV | 
| Max.capacity: | 108KVA | 
| Max. voltage: | 27KV , 54KV, 81KV , 108KV | 
| Design feature: | Portable Type , Lighter Single Piece Weight, Special for On-site Installation and test | 
| Component:: | V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider | 
| Test frequency: | 30-300Hz | 
| Duty cycle: | 60 mints | 
| Test accuracy: | No less than 1.5% | 
| Output waveform: | Good sine wave | 
| Test object: | 35KV cable , 10KV cable, 35KV power substation | 
| Test standard: | IEC 60060-1:2010;IEC 62271-203:2011 for GIS, IEC 60840:2011 for XLPE cable; | 
Portable Variable Frequency Resonant Withstand Voltage Test Set , For 35KV Cable and Power Substation Test
I. Product Usage :
This test set model CHX-108KVA/27KV, 108KV is designed for 10KV /
35KV class XLPE cable ,power transformer, CB,CT/PT, busbar in 35KV
power substation to perform on-site AC withstand voltage test with variable frequency resonant circuit
technology; the highest test voltage is no more than 27KV
,54KV,108KV; test frequency: 30-300Hz; the duty cycle is no more
than 60mints. it can help customers to perform preventive test or
hand-over test on AC withstand voltage test
Test range of the set is as following:transformer
1. 500m of 35kV/300mm2 cable, test frequency 30-300Hz, test voltage 52kV, test time 60min.
2, 2000m of 10kV/300mm2 cable , test frequency 30-300Hz, test voltage 22kV, test time 5min.
3, 35kV/31500kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 68kV, test time 1min.
4, CB,CT/PT, busbar in 35KV power substation , test frequency 40-300Hz, test voltage does not exceed 95kV, test time 1min.
The whole test set consists of variable frequency power source , excitation transformer , 4pieces of reactors, and high voltage measurement devider(capacitive voltage divider). This type of test set is most suitable for 35KV power sub-station
II. General Technical Data
III. Main Components:
| SN | Name of Components | Type and specification | Qty. | Each weight | Each Dimension | 
| 1 | Variable frequency power | FKVF-5kW/380V | 1piece | 35kgs | 450*450*500mm | 
| 2 | Excitation transformer | CQSB(J)-5kVA/1.25KV,5KV | 1piece | 35kgs | 450*350*450mm | 
| 3 | HV resonant test reactor | CHX(kf)-27kVA/27kV | 4pieces | 42kgs | D350*H400mm | 
| 4 | Capacitive divider | TRF-110kV/1000pF | 1set | 10kgs | D150*H850mm | 
| 5 | Special test accessories | 1set | 
IV. Test priciple :
VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm
)
V. Main Measuring and control software panel:
Note: This is the software panel before start test for parameter
setting
VI.Accessories
VII. Other Optional Model
1. For GIS on-site test
| Model | Rated voltage | Rated output current | Rated output capacity | Application (From 45Hz starting) | 
| CHX-135KVA/135KV | 27KV*5 | 1A | 135KVA | For 72.5KV and below GIS | 
| CHX-270KVA/135KV | 27KV*5 | 1A | 135KVA | For 72.5KV and below GIS | 
| CHX-216KVA/216KV | 27KV*8 | 1A | 216KVA | For 123KV and below GIS | 
| CHX-270KVA/270KV | 27KV*10 | 1A | 270KVA | For 145KV and below GIS | 
| CHX-275KVA/275KV | 275KV | 2A | 275KVA | For 170KV and below GIS | 
| Special requirement can be made by order | ||||
2. For 45KV XLPE cable on-site test
| Model | Rated voltage | Rated output current | Rated output capacity | Max Application | 
| CHX-108/54 | 54KV | 2A | 108KVA | 45kV cable≤1km | 
| CHX-216/54 | 54KV | 4A | 216KVA | 45kV cable≤2km | 
| CHX-324/54 | 54KV | 6A | 324KVA | 45kV cable≤3km | 
| CHX-432/54 | 54KV | 8A | 432KVA | 45kV cable≤4km | 
| CHX-540/54 | 54KV | 10A | 540KVA | 45kV cable≤5km | 
| CHX-1080/54 | 54KV | 20A | 1080KVA | 45kV cable≤10km | 
| Special requirement can be made by order | ||||
3. For 66KV XLPE cable on-site test
| Model | Rated voltage | Rated output current | Rated output capacity | Max Application | 
| CHX-160/80 | 80KV | 2A | 160KVA | 66kV cable≤0.5km | 
| CHX-320/80 | 80KV | 4A | 320KVA | 66kV cable≤1km | 
| CHX-640/80 | 80KV | 8A | 640KVA | 66kV cable≤2km | 
| CHX-960/80 | 80KV | 12A | 960KVA | 66kV cable≤3km | 
| CHX-1280/80 | 80KV | 16A | 1280KVA | 66kV cable≤4km | 
| CHX-1600/80 | 80KV | 20A | 1600KVA | 66kV cable≤5km | 
| CHX-3200/80 | 80KV | 40A | 3200KVA | 66kV cable≤10km | 
| CHX-9600/80 | 80KV | 120A | 9600KVA | 66kV cable≤20km | 
| Special requirement can be made by order | ||||
VIII. On-site insulation test standard table from IEC 60840:2011 for XLPE cable

|   | 
 810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30-300Hz
                                                                                    
                        
                        
                        
                                                            810KVA High Voltage Test Kit , 35KV And 132KV Hv Cable Testing Equipment 30-300Hz
                                                    
                        
                     45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test
                                                                                    
                        
                        
                        
                                                            45KV 270KV AC Resonant Test System For 35KV Cable And 110KV Power Substation Test
                                                    
                        
                     132KV GIS Testing AC Resonant Test System Lighter Single Piece Weight
                                                                                    
                        
                        
                        
                                                            132KV GIS Testing AC Resonant Test System Lighter Single Piece Weight
                                                    
                        
                     FKVF Series High Voltage Testing Of Electrical Equipments 5KW~400KW Capacity Optional
                                                                                    
                        
                        
                        
                                                            FKVF Series High Voltage Testing Of Electrical Equipments 5KW~400KW Capacity Optional
                                                    
                        
                     High Accuracy Thermal Generator Test Equipment / Ac High Voltage Tester Low Noise
                                                                                    
                        
                        
                        
                                                            High Accuracy Thermal Generator Test Equipment / Ac High Voltage Tester Low Noise
                                                    
                        
                     30-300Hz Frequency High Voltage Resonant Test System With V/F Power Source
                                                                                    
                        
                        
                        
                                                            30-300Hz Frequency High Voltage Resonant Test System With V/F Power Source
                                                    
                        
                     Power Frequency AC Resonant Test System For EHV CVT And CB Rutine Testing
                                                                                    
                        
                        
                        
                                                            Power Frequency AC Resonant Test System For EHV CVT And CB Rutine Testing
                                                    
                        
                     380V AC Resonant Test System Power Frequency Resonant Intelligent Control Unit
                                                                                    
                        
                        
                        
                                                            380V AC Resonant Test System Power Frequency Resonant Intelligent Control Unit
                                                    
                        
                     Variable Frequency AC Resonant Test System , High Voltage Test Set For UHV Substation Or GIS
                                                                                    
                        
                        
                        
                                                            Variable Frequency AC Resonant Test System , High Voltage Test Set For UHV Substation Or GIS
                                                    
                        
                     2100kVA Adjusting Inductance Type Series Resonance Test system
                                                                                    
                        
                        
                        
                                                            2100kVA Adjusting Inductance Type Series Resonance Test system