| Sign In | Join Free | My futurenowinc.com |
|
| Categories | Industrial Servo Motor |
|---|---|
| Brand Name: | Yasakawa |
| Model Number: | SGMCS-07B3B11 |
| Place of Origin: | Japan |
| MOQ: | 1 |
| Price: | negotiable |
| Payment Terms: | T/T, Western Union |
| Supply Ability: | 100 |
| Delivery Time: | 2-3 work days |
| Packaging Details: | New in original box |
| Brand: | Yasakawa |
| Model: | SGMCS-07B3B11 |
| Palce of Origin: | Japan |
| Type: | Servo Motor |
| Supply Voltage: | 147W |
| Current: | 1.4A |
| Ins: | A |
| r/min: | 100 |
| Company Info. |
| Shenzhen Wisdomlong Technology CO.,LTD |
| Verified Supplier |
| View Contact Details |
| Product List |
Industrial Servo Motor , YASKAWA AC Servo 147W 200V AC Servo Motor SGMCS-07B3B11
OTHER SUPERIOR PRODUCTS
| Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
| Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
| Honeywell TC-,TK- | GE Modules IC - |
| Fanuc motor A0- | Yokogawa transmitter EJA- |
| SGMCS-02B3C11 | SGMCS-02B3C41 |
| SGMCS-04C3B1 | SGMCS-17D3C1 |
| SGMCS-07B3B11 | SGMPH-02AAA2C |
| SGMCS-07B3C11 | SGMCS-35E3A-MB11 |
| SGMCS-08DDA-TE12 | SGMCS-35E3A--MB11 |
| SGMCS-17D3A-MB11 | SGMCS-80M3A11 |
WARNING! DO NOT CONNECT ANY OF THE FOLLOWING TERMINALS TO EARTH GROUND

C6-01 Drive Duty Selection Setting
0: Heavy Duty
• Rated output current is the HD (Heavy Duty) rating on drive
nameplate.
• Overload capacity is 150 % for 1 minute.
• Carrier frequency is defaulted to 2 kHz but can be increased to 8
kHz or 5 kHz w/o derating on certain models (Refer to Appendix 1)
• Carrier frequency is automatically reduced when:
• output frequency is < 6.0 Hz and current is >100 %
• output frequency is > 6.0 Hz and current is > 112 %
• Maximum output frequency is 400 Hz (except on larger models)
• L8-15: OL2 Characteristic selection@low speed (=1 Enabled)
expedites OL2 at low output frequencies below 6 Hz.
1: Normal Duty (default)
• Output current is ND (Normal Duty) rating on drive nameplate.
• Overload capacity is 120 % for 1 minute.
• Carrier frequency is defaulted to Swing PWM (2kHz) but can be
increased with derating on most models (Refer to Appendix 1)
• Carrier is automatically reduced when:
• output frequency is < 6.0 Hz and current is >100 %
• output frequency is > 6.0 Hz and current is > 112 %
• Maximum output frequency is 400 Hz (except on certain larger
models)
• L8-15: OL2 Characteristic selection@low speed (=1 Enabled)
expedites OL2 at low output frequencies below 6 Hz
Similar to Normal Duty, but with 150 % OL
• Singular output current value on nameplate.
• Overload capacity is 150 % for 1 minute.
• Full range carrier adjustment C6-02.
• Drive must be derated when carrier is set above default, software
protected by OL2.
• Maximum output frequency is 400 Hz.
• L8-15: Characteristic selection @ low speed (=1 Enabled)
expedites OL2.
|