| Sign In | Join Free | My futurenowinc.com | 
 | 
| Categories | Inductive Load Bank | 
|---|---|
| Brand Name: | KAIXIANG | 
| Model Number: | AC400-1000KVA | 
| Certification: | ISO9001 | 
| Place of Origin: | CHINA | 
| MOQ: | 1 set | 
| Price: | negotiable | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 15 Sets per Month | 
| Delivery Time: | Within 30 working days | 
| Packaging Details: | Wooden Case for Load bank | 
| Casing Dimensions and Cooling: | about 4000*2350*2591mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling | 
| Transportation: | Hoisting, there are lifting lug in top of casing | 
| Casing Color: | Grey(RAL7035) | 
| Ambient Temperature: | -10℃~+50℃ | 
| Voltage range: | AC400v 50hz ±10% | 
| Display Precision: | 0.5 class | 
AC Genset Load Bank 1000KVA Load Bank Cabinet Grey Casing Color
Product description
Manufacturers of small gas engines also use load banks to test
newly manufactured engines under various mechanical loads. This is
accomplished by connecting the engine to the load bank via a device
called a dynamometer. Again, engine performance is monitored and,
if necessary, adjustments are made to ensure the product performs
within intended specifications.
Technical Parameter
| Rating Voltage/Frequency | 400VAC/50Hz, 3 phase 4 wire, | 
| Voltage range | 400v 50hz ±10% | 
| Max Rated power | Apparent Power: 1000kVA | 
| Load Resolution | Resistive load:1.2.2.5.10.10.20.50.100.200.200.200kw | 
| Load Tolerance (each step) | ±5% | 
| Load Tolerance(overall) | ±3% | 
| Display Precision | 0.5 class | 
| Control Power | AC380VAC/50Hz,3 phase 4 wire | 
| Wire Connection | Load power supply input——Copper bar (star coupling) | 
| Communication Interface | RS485, | 
| Casing Dimensions and Cooling | about 4000*2350*2591mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling | 
| Weight | About 3600kgs/set | 
| Transportation | Hoisting, there are lifting lug in top of casing | 
| Casing Color | Grey(RAL7035) | 
| Ambient Temperature | -10℃~+50℃ | 
| Relative Humidity | ≤95% | 
| Altitude | ≤1500 meter | 
| Atmospheric Pressure | 86~106kPa | 
| Contactor | Schneider | 
| Fuse | DELIXI | 
| MCU | INFINEON | 
| Data processing software | Kaixiang(self-developed) | 
| Alloy Resistance | Kaixiang(self-developed) | 
Product Advantage
1.User can press the emergency stop button in the panel to unload
immediately when the load bank is abnormal while working.
2.Over-load: Automatic load dump and give alarm when voltage is
over safety thresholds.
3.Short Circuit Protection: Fuse could avoids damage to equipment
when short circuit or current overload.
4.Fan protection: Machine could not do load testing before working
power of fan is on.
5.The machine will unload and give alarm when any fan is abnormal
or with insufficient air volume, etc.
Application
1.Manufacturers of small gas engines also use load banks to test
newly manufactured engines under various mechanical loads.
2.This is accomplished by connecting the engine to the load bank
via a device called a dynamometer.
3.engine performance is monitored and, if necessary, adjustments
are made to ensure the product performs within intended
specifications.
|   | 
 Yellow Apparent Power Capacitive Load Bank Local Control With 3 Phase 4 Wire
                                                                                    
                        
                        
                        
                                                            Yellow Apparent Power Capacitive Load Bank Local Control With 3 Phase 4 Wire
                                                    
                        
                     400 V 1375 Kva Inductive Load Bank Grey With 86~106 KPa Atmospheric Pressure
                                                                                    
                        
                        
                        
                                                            400 V 1375 Kva Inductive Load Bank Grey With 86~106 KPa Atmospheric Pressure
                                                    
                        
                     Three Phase Output Ups Load Bank , Ocean Engineering Resistance Load Bank
                                                                                    
                        
                        
                        
                                                            Three Phase Output Ups Load Bank , Ocean Engineering Resistance Load Bank
                                                    
                        
                     Custom Design Inductive Load Bank Apparent Power For Testing Output Power
                                                                                    
                        
                        
                        
                                                            Custom Design Inductive Load Bank Apparent Power For Testing Output Power
                                                    
                        
                     Accurate Test Hoisting Automatic Load Bank Remote Control For Malaysia
                                                                                    
                        
                        
                        
                                                            Accurate Test Hoisting Automatic Load Bank Remote Control For Malaysia
                                                    
                        
                     1100KW Inductive Load Bank , 1375 KVA  Office Buildings Three Phase Load Bank
                                                                                    
                        
                        
                        
                                                            1100KW Inductive Load Bank , 1375 KVA  Office Buildings Three Phase Load Bank
                                                    
                        
                     Multifarious Voltage Reactive Load Bank High Power For Customer Choose
                                                                                    
                        
                        
                        
                                                            Multifarious Voltage Reactive Load Bank High Power For Customer Choose
                                                    
                        
                     1500 KVA 1200KW Inductive Load Bank Resistive With Short Circuit Protection
                                                                                    
                        
                        
                        
                                                            1500 KVA 1200KW Inductive Load Bank Resistive With Short Circuit Protection
                                                    
                        
                     Intelligent / Remote Control AC Load Bank , Robust Water Cooled Load Bank
                                                                                    
                        
                        
                        
                                                            Intelligent / Remote Control AC Load Bank , Robust Water Cooled Load Bank 
                                                    
                        
                     Resistive Power Capacitive Load Bank 3630 Kvar For Generator Testing
                                                                                    
                        
                        
                        
                                                            Resistive Power Capacitive Load Bank 3630 Kvar For Generator Testing