| Sign In | Join Free | My futurenowinc.com | 
 | 
| Categories | High Efficiency Gas Steam Boiler | 
|---|---|
| Brand Name: | LEWAY Brand | 
| Model Number: | WNS | 
| Certification: | SGS, ISO, OHSAS | 
| Place of Origin: | Henan, China (Mainland) | 
| MOQ: | 1 | 
| Price: | Negotiable | 
| Supply Ability: | 3000 Ton/Tons per Year | 
| Delivery Time: | Within 20 working days | 
| Packaging Details: | PE films pack boiler's main-body, spare parts packed with PE film and metal boxes | 
| Style: | Horizontal | 
| Output: | Steam | 
| Structure: | Fire Tube | 
| Condition: | New | 
| Operation: | ON-OFF Computer Control | 
| Pressure: | Low Pressure | 
| Warranty: | 2Years | 
| Product Name: | High Efficiency Gas Steam Boiler | 
Warranty 2 Years Gas Steam Boiler Long Service Life and Safety Steam Boiler
Product Features
1. Quality Burner: gas fired steam boiler adopting high quality low nitrogen split-type burner; preheat the air for burner, raise the furnace's temperature and increase combustion efficiency.
2. High Efficiency 95%: Wet-back technology replace traditional dry-back design, effectively increase boiler’s water heating surface, and protect the smoke-box from the over-temperature damage. Three passes structure, Large diameter corrugated furnace and corrugated fire tubes to increase boiler heating surface to better absorb the heat. Additional, it also equipped with condenser(finned tube type) to full using the massive latent heat in the exhaust gas; and the high temperature condensing water also can be fed into the boiler again.
3. Convenient Installation/ Maintenance: WNS series gas fired steam boiler gets compact structure and openable front/ back smoke boxes, man-hole, hand-hole, platform ladder. Above designs are convenient for installation, maintenance.
Steam Boiler Model
| Item Unit Model | WNS 0.5-1.0 -Y(Q) | WNS 1- 1.0 -Y(Q) | WNS 1- 1.25 -Y(Q) | WNS 1.5- 1.0 -Y(Q) | WNS 2- 1.0 -Y(Q) | WNS 2- 1.25 -Y(Q) | WNS 3- 1.25 -Y(Q) | WNS 4- 1.25 -Y(Q) | WNS 6- 1.25 -Y(Q) | WNS 8- 1.25 -Y(Q) | WNS 10- 1.25 -Y(Q) | WNS 15- 1.25 -Y(Q) | WNS 20- 1.25 -Y(Q) | ||
| Rated Capacity | t | 0.5 | 1 | 1 | 1.5 | 2 | 2 | 3 | 4 | 6 | 8 | 10 | 15 | 20 | |
| Feedwater Temp | ℃ | 20 | |||||||||||||
| Steam Pressure | MPa | 1.0 | 1.0 | 1.25 | 1.0 | 1.0 | 1.25 | ||||||||
| Steam Temperature | ℃ | 183.2 | 183.2 | 194 | 183.2 | 183.2 | 194 | ||||||||
| Heating Surface | ㎡ | 25.1 | 35.2 | 36.4 | 53.55 | 73.1 | 68 | 106.7 | 141.5 | 185.8 | 261.8 | 351.1 | 513.9 | 616.7 | |
| Thermal Efficiency | % | 95%-99% | |||||||||||||
| Fuel Consumption | Diesel | Kg/h | 31 | 67 | 69 | 101.6 | 132.6 | 133.7 | 198 | 280.1 | 386.1 | 550 | 681 | 1020.8 | 1372.2 | 
| Gas | Nm³/h | 38.2 | 72 | 72 | 108 | 144 | 144 | 216 | 288 | 432 | 572 | 718 | 1076 | 1410 | |
| Power Consumption | KW | 3.2 | 5 | 5 | 6 | 7 | 7 | 15 | 15 | 20 | 26 | 40 | 55 | 65 | |
| Boiler Weight | t | 3.5 | 4.8 | 5.3 | 5.9 | 6.8 | 7.2 | 9.1 | 12.3 | 16.2 | 19.6 | 27.4 | 38 | 47 | |
| Water Volume | m³ | 1.8 | 2.8 | 2.8 | 3.6 | 3.9 | 3.9 | 6.3 | 8.5 | 9 | 13.3 | 13.6 | 23.5 | 32.3 | |
| External Dimension | L | mm | 2954 | 3000 | 3300 | 3400 | 3800 | 3800 | 4300 | 4580 | 5300 | 6254 | 6373 | 7415 | 7830 | 
| W | mm | 1394 | 1760 | 1760 | 2050 | 2000 | 2000 | 2050 | 2280 | 2380 | 2528 | 2640 | 3360 | 3500 | |
| H | mm | 1752 | 2100 | 2150 | 2250 | 2200 | 2350 | 2550 | 2550 | 2645 | 3015 | 3124 | 3510 | 3998 | |
| Live Steam Pipe | mm | 50 | 50 | 50 | 65 | 80 | 80 | 80 | 100 | 125 | 150 | 150 | 200 | 250 | |
| Water Inlet Pipe | mm | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 65 | |
| Relief Valve Pipe | mm | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 65 | 80 | 80 | 100 | 100 | |
| Drain Pipe | mm | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | |
| Chimney | mm | 300 | 300 | 300 | 300 | 350 | 350 | 400 | 400 | 600 | 700 | 800 | 900 | 1000 | |
| Basement | L | mm | 2240 | 2835 | 2835 | 2900 | 3100 | 3100 | 3360 | 3560 | 4100 | 5200 | 5380 | 6180 | 6800 | 
| W | mm | 950 | 1100 | 1100 | 1200 | 1200 | 1200 | 1450 | 1500 | 1750 | 2000 | 2100 | 2300 | 2650 | |
| Transport Size | L | mm | 2954 | 3254 | 3254 | 3442 | 3886 | 4002 | 4260 | 4794 | 5372 | 6646 | 6882 | 7407 | 8166 | 
| W | mm | 1556 | 1770 | 1770 | 1900 | 1900 | 1900 | 2130 | 2180 | 2198 | 2600 | 2600 | 3193 | 3400 | |
| H | mm | 1727 | 2072 | 2072 | 2159 | 2172 | 2177 | 2425 | 2502 | 2635 | 3043 | 3246 | 3553 | 4027 | |
Usage
Gas fired steam boiler be widely used in Medicine, chemical, light industry, textile, building material, cultivation, food and beverage, plastic foam, printing, dyeing and washing, rubber processing, paper products,wood processing, hotel, clothing and leather manufacturer etc.


|   | 
 Horizontal High Efficiency Gas Steam Boiler 8000kg Steam Capacity Less Pollution
                                                                                    
                        
                        
                        
                                                            Horizontal High Efficiency Gas Steam Boiler 8000kg Steam Capacity Less Pollution
                                                    
                        
                     High Safety Natural Gas Boiler Furnace , Most Efficient Gas Boiler Enhanced Strength
                                                                                    
                        
                        
                        
                                                            High Safety Natural Gas Boiler Furnace , Most Efficient Gas Boiler Enhanced Strength
                                                    
                        
                     Three Return 2T High Efficiency Gas Steam Boiler Fire Tube Structure
                                                                                    
                        
                        
                        
                                                            Three Return 2T High Efficiency Gas Steam Boiler Fire Tube Structure
                                                    
                        
                     Three Passes High Efficiency Gas Steam Boiler 95% Thermal Efficiency
                                                                                    
                        
                        
                        
                                                            Three Passes High Efficiency Gas Steam Boiler 95% Thermal Efficiency
                                                    
                        
                     Fully Automatic High Efficiency Gas Steam Boiler For Food Sterilization
                                                                                    
                        
                        
                        
                                                            Fully Automatic High Efficiency Gas Steam Boiler For Food Sterilization
                                                    
                        
                     New Condition Energy Saving Gas Boilers , Gas Condensing Boiler Large Heating Surface
                                                                                    
                        
                        
                        
                                                            New Condition Energy Saving Gas Boilers , Gas Condensing Boiler Large Heating Surface
                                                    
                        
                     Horizontal Style Natural Gas Steam Furnace Good Thermal Insulation Effect
                                                                                    
                        
                        
                        
                                                            Horizontal Style Natural Gas Steam Furnace Good Thermal Insulation Effect
                                                    
                        
                     Wet Back Design High Efficiency Gas Steam Boiler Feedwater Temp 20℃ For Laundry
                                                                                    
                        
                        
                        
                                                            Wet Back Design High Efficiency Gas Steam Boiler Feedwater Temp 20℃ For Laundry
                                                    
                        
                     Fire Tube High Efficiency Gas Steam Boiler 0.5T - 20T
                                                                                    
                        
                        
                        
                                                            Fire Tube High Efficiency Gas Steam Boiler 0.5T - 20T
                                                    
                        
                     1.8 - 3.9m³ Water Volume Gas Fired Boiler , High Efficiency Gas Boiler OHSAS Approved
                                                                                    
                        
                        
                        
                                                            1.8 - 3.9m³ Water Volume Gas Fired Boiler , High Efficiency Gas Boiler OHSAS Approved