LCD touch screen weekly programmable electric floor heating thermostats
Touch Screen Period Programming Thermostat Weekly circulation, it
is possible to set 6 periods called events each day with
corresponding pre-set temperatures, also you can select "period
control mode" or "manual mode" according to your individual
requirements. The thermostat is recommended for the control of
electric heating devices or on/off valve actuator used in
water-based heating systems.
Technical data
| Power Supply | AC200-240VAC 50/60HZ | 
| Accuracy | ±0.5ºC | 
| Probe sensor | NTC | 
| Power Consumption | <0.3W | 
| Load current | 3A(water heating),16A(electric heating) | 
| Temperature Adjustable Range | 5°C~90°C( can adjust to 35°C~90°C) | 
| Limit Temperature Range | 5°C~60°C( factory setting: 35°C) | 
| Output | Switch relay | 
| Insulating condition | Normal environment | 
| Running program | Set per 1 week as a cycle | 
| Installation | Wall mounted | 
| Application | Water Floor Heating System | 
| Electric Floor Heating System | |
| Infrared Heater System | |
| Certificate | CE,RoHS | 
Advanced setting (qualified person preferred)
You can press "M" and"Time"and hold for 5 seconds at the same time
to enter the mode of advanced setting when the thermostat is turned
off. The following seven function can be chosen by pressing "M".
| Symbol | Setting | Up or Down | |
| 1 | ADJ | Temperature calibration | Adjust measured temperature | 
| 2 | SEN | Sensor mode | IN: built-in sensor  | 
| 3 | LIT | Limitation temperature | Adjust limitation value,  | 
| 4 | DIF | Switching differential | Adjust switching differential | 
| 5 | LTP | Antifreeze function | Turn on/off Anti-frozen function | 
| 6 | PRG | Set vacation mode | 2: 5/2 day mode  | 
| 7 | RLE | Potential-free output | 00: in same way  | 
| 8 | DLY | Potential-free output delay | Change the delay time | 
| 9 | HIT | Max. Temperature | Max. Limitation temperature set point (99℃) | 
| 10 | AFAC | Reset to factory settings | Programming parameters will be reset to factory settings when
symbol " " appears | 


Sensor failure
Please select the right sensor mode when operation, it will display
the "Err" symbol on screen far sensor failure, thermostat must be
checked till the fault is eliminated.
                                 
                             |