| Sign In | Join Free | My futurenowinc.com | 
 | 
| Categories | Three Phase Voltage Monitoring Relay | 
|---|---|
| Brand Name: | GINRI | 
| Model Number: | JVRD-380N | 
| Certification: | CE,CCC | 
| Place of Origin: | CHINA | 
| MOQ: | 20Pcs | 
| Payment Terms: | L/C, T/T, Western Union,Paypal | 
| Supply Ability: | 20000Pcs per month | 
| Delivery Time: | 1-30 days upon order quatity | 
| Packaging Details: | Voltage relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable. | 
| Function: | Phase sequence, phase loss, overvoltage, undervoltage | 
| Indicators: | 5LEDS | 
| Rated Voltage: | AC220V 380V 440V 460V 480V | 
| Output contacts: | 2 C/O(1C/O &1NC for 3-phase 4-wire) | 
| Mechanical durability: | 1000000 cycles | 
| Phase unbalance threshold: | 15% fixed | 
Refrigeration Units Three Phase Voltage Monitoring Relay phase reversal protect
Neutral loss monitoring function could protect The three-phase circuit composed of a single-phase load is generally asymmetrical. At this time, three-phase four-wire power supply should be used. The role of the neutral line is to ensure that the voltage of each phase is still symmetrical when the load is asymmetric, and it can work normally; if a phase break occurs, it will only affect the load of this phase without affecting the other two-phase load. However, if the neutral wire is disconnected for any reason, when the load of each phase is asymmetric, it will inevitably cause the distortion of each phase voltage and damage the normal operation of each phase load. Therefore, in the three-phase four-wire power supply system, the neutral line is not allowed to open circuit.
What the function of the neutral
The three-phase load star connection method is symmetrical. When there is a neutral line and there is no neutral line, when the load is asymmetrical and there is no neutral line, the actual phase voltage of the load with a large impedance is higher than the rated voltage and becomes bright or burned, making the impedance A small load phase voltage dims below the rated voltage. None of them work properly. The role of the midline is: in the three-phase asymmetry, the neutral line can make the three-phase load still get symmetrical phase voltage and work normally
In addition, when the collision is caused by the insulation damage of the electrical equipment with zero protection, the short-circuit current will form a loop through the zero line. Since the zero line impedance is small, the short-circuit current will be very large, which will prompt the protection device to quickly act to disconnect the power supply. In order to play a protective role;
Description
-- Compact modular size
-- Three-phase monitoring of phase sequence, phase loss, over- and undervoltage and phase unbalance
-- Powered by the measuring circuit
-- 2 C/O contacts
-- 5 LEDs for status indication
-- Phase sequence
-- Phase loss
-- Overvoltage
-- Undervoltage
-- Phase unbalance
• Pumps • Fans
• Blowers • Motors
• Compressors
• CE • CCC
♦ Technical data
| Type | JVRD-380 | ||||||||||||||||||
| Measuring circuit | L1,L2,L3 | ||||||||||||||||||
| Rated voltage | 220VAC,380VAC,440VAC 460VAC,480VAC,50/60Hz | ||||||||||||||||||
| Monitoring functions | phase sequence,phase loss,overvoltage, undervoltage,phase unbalance | ||||||||||||||||||
| Voltage setting range | 
 | ||||||||||||||||||
| Indicators | phase sequence,phase loss,overvoltage, undervoltage and normal | ||||||||||||||||||
| Output contacts | 2 C/O | ||||||||||||||||||
| Contact capacity | 6A,250VAC | ||||||||||||||||||
| Dimensions(H*W*D) | 79*23*79mm | ||||||||||||||||||
| Mounting | DIN Rail | ||||||||||||||||||

|   | 
 Pumps Three Phase Voltage Monitoring Relay , JVM-A Phase Detection Relay 460VAC
                                                                                    
                        
                        
                        
                                                            Pumps Three Phase Voltage Monitoring Relay , JVM-A Phase Detection Relay 460VAC
                                                    
                        
                     Phase sequence Three Phase Voltage Monitoring Relay Miniature voltage relay
                                                                                    
                        
                        
                        
                                                            Phase sequence Three Phase Voltage Monitoring Relay Miniature voltage relay
                                                    
                        
                     Digital Three Phase Voltage Monitoring Relay Over voltage protector AC380V 6A
                                                                                    
                        
                        
                        
                                                            Digital Three Phase Voltage Monitoring Relay Over voltage protector AC380V 6A
                                                    
                        
                     Elevator part Three Phase Voltage Monitoring Relay phase failure protective deivce 380VAC Din rail
                                                                                    
                        
                        
                        
                                                            Elevator part Three Phase Voltage Monitoring Relay phase failure protective deivce 380VAC Din rail
                                                    
                        
                     Water Pumps Three Phase Voltage Monitoring Relay 380V protector 1CO  6A contact capacity
                                                                                    
                        
                        
                        
                                                            Water Pumps Three Phase Voltage Monitoring Relay 380V protector 1CO  6A contact capacity
                                                    
                        
                     Compressors Used Three Phase Voltage Monitoring Relay 1-25s time delay protector
                                                                                    
                        
                        
                        
                                                            Compressors Used Three Phase Voltage Monitoring Relay 1-25s time delay protector
                                                    
                        
                     6A Three Phase Voltage Monitoring Relay for electric motors voltage control relay
                                                                                    
                        
                        
                        
                                                            6A Three Phase Voltage Monitoring Relay for electric motors voltage control relay
                                                    
                        
                     Undervoltage Phase Voltage Monitoring Relay 3 Phase-rotation and phase loss monitoring relay , SPDT 380V
                                                                                    
                        
                        
                        
                                                            Undervoltage Phase Voltage Monitoring Relay 3 Phase-rotation and phase loss monitoring relay , SPDT 380V
                                                    
                        
                     Phase failure detection Three Phase Voltage Monitoring Relay 200V-500V , 50/60Hz
                                                                                    
                        
                        
                        
                                                            Phase failure detection Three Phase Voltage Monitoring Relay 200V-500V , 50/60Hz
                                                    
                        
                     Phase reversal protector Three Phase Voltage Monitoring Relay 2 CO , 6A
                                                                                    
                        
                        
                        
                                                            Phase reversal protector Three Phase Voltage Monitoring Relay 2 CO , 6A