| Product List | 
Light Testing Equipment Lamp Tilt Test Bench 0-30 Degree GB7000
Product information:
This device complies with GB7000 and other standards, the device consists of a work surface and angle adjustment device, is suitable for all types of portable lamps and similar electrical appliances products for mechanical stability test, the test sample is placed on countertops, to assess its mechanical stability through different tilt angles.
Technical specification and parameter configuration
| Working condition: Environment:0℃~+40℃;Working power supply :220V±10% 50Hz | 
| Technical index: 1, Tilt angle :0-30 ° stepless adjustable, electric control, encoders intelligent digital display; equipped with angle measuring instrument calibration, easy to operate, high accuracy angle, precision ± 0.5 °; 2, The maximum weight load: 50kg, (load can be improved as per customer requirements)steel plate surface is treated by painting; 3, Motor speed: 0.50r/min (frequency control for optional), there are reliable earthing contact and power plug connector on the test bench of accessible metal surface; 4, Table diameter: 800mm; 5, The test bench with stable whole structure, and beautiful appearance. | 
|   | 
 Circuit Light Testing Equipment Rectifying Effect Of High Pressure Sodium And Metal Halide Lamps
                                                                                    
                        
                        
                        
                                                            Circuit Light Testing Equipment Rectifying Effect Of High Pressure Sodium And Metal Halide Lamps
                                                    
                        
                     7006-47C For G5 Lampholders , 7006-60C For G13 Lampholders
                                                                                    
                        
                        
                        
                                                            7006-47C For G5 Lampholders , 7006-60C For G13 Lampholders
                                                    
                        
                     Light Testing Equipment LED Aging Test Device 1000 Hours Test Duration
                                                                                    
                        
                        
                        
                                                            Light Testing Equipment LED Aging Test Device 1000 Hours Test Duration
                                                    
                        
                     IEC 60598-1 Clause 8.15 Arrangement For Impact Test For Handlamps With A Handle Or Shell Of Flexible Material
                                                                                    
                        
                        
                        
                                                            IEC 60598-1 Clause 8.15 Arrangement For Impact Test For Handlamps With A Handle Or Shell Of Flexible Material
                                                    
                        
                     IEC 61347-1 Annex D Test Chamber Heating Enclosure For Thermally Protected Ballasts / Rectifier Thermal Protection
                                                                                        
                                                        
                        
                        
                        
                                                            IEC 61347-1 Annex D Test Chamber Heating Enclosure For Thermally Protected Ballasts / Rectifier Thermal Protection
                                                    
                        
                     Double-walled cylinder , IEC 60598-1 Annex K Temperature measurement
                                                                                    
                        
                        
                        
                                                            Double-walled cylinder , IEC 60598-1 Annex K Temperature measurement
                                                    
                        
                     Measurement Lab Test Machines Of Touch Current And Protective Conductor Current
                                                                                    
                        
                        
                        
                                                            Measurement Lab Test Machines Of Touch Current And Protective Conductor Current
                                                    
                        
                     IEC61347-1-Figure G.2 Circuit For Producing And Applying Long - Duration Pulses
                                                                                    
                        
                        
                        
                                                            IEC61347-1-Figure G.2 Circuit For Producing And Applying Long - Duration Pulses
                                                    
                        
                     IEC 62262 IK Pendulum Hammer , Pendulum Impact Hammer For Specifying Enclosure Capacity
                                                                                    
                        
                        
                        
                                                            IEC 62262 IK Pendulum Hammer , Pendulum Impact Hammer For Specifying Enclosure Capacity
                                                    
                        
                     Electrodynamic Vibration Test Systems Large Displacement Vertical Or Horizontal Operation
                                                                                    
                        
                        
                        