| Sign In | Join Free | My futurenowinc.com |
|
| Categories | Electrical Appliance Tester |
|---|---|
| Brand Name: | HongCe |
| Model Number: | HJ0641 |
| Certification: | Third party calibration certificate(cost additional) |
| Place of Origin: | China |
| MOQ: | 1 set |
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability: | 1 set/month |
| Delivery Time: | 45 days |
| Packaging Details: | Plywood |
| Price: | Negotiatable |
| Voltage: | AC(10V~300V) |
| Current: | AC(0.01A~20A) |
| Flowmeter: | (0.5~5) CBM/min |
| Vacuum pressure gauge: | (0~-50)Kpa |
| Standard: | IEC 60312 |
| Temperature compensation and correction: | IEC 60312 clause 5.2.8.4 air density standard air density |
| Company Info. |
| Guangzhou HongCe Equipment Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
Vacuum Cleaner Test System To Test Vacuum Cleaner Performance European Standard According To Standard IEC 60312 HJ0641
Standard :IEC60312 clause2.1.5 fig1,clause 2.1.2 fig2,clause 2.1.3 fig4,clause 5.2.2 fig5,clause 5.2.3 fig6,clause 5.2.4 fig7a,7b,7c,7d .
Application: It is used for the manufacturers and testing organizations to test the vacuum cleaner.Test parameters: the voltage of vacuum cleaner ,the current ,input power , power factor, suction power, flow rate, vacuum and efficiency
Test sample: Vacuum cleaner
Feature:
1.According to European standard requirements, European standard A test method for throttle valve, control valve opening size, a total of 15 points
2,Inflatable chamber (uniform pressure box): European standard size and material according to standard IEC 60312 in the 5.2.8.1 (A) design
3,Test tube: in Europe standard, the test pipe is formed by throttling valve and steel pipe, and the measuring accuracy is + 2%
4,Voltage AC(10V~300V),Accuracy:0.5%
Current AC(0.01A~20A),Accuracy:0.5%
Flowmeter(0.5~5) CBM/min Accuracy:±1%
Vacuum pressure gauge: (0~-50)Kpa ,Accuracy:±1%
5,Temperature compensation and correction: The European standard is modified according to standard air density in accordance with 5.2.8.4 of IEC 60312.
Basic test process:
1.Conforms to the requirements of IEC 60312 clause 2.8)
2.Place the vacuum cleaner on the test bench and transfer the test voltage to + 1% rated voltage and + 1Hz rated frequency. First, run 10 minutes to establish a temperature reference value for the release gas for measurements at each point below. For each measuring point, measure after 1 minutes after throttling, and then vacuum cleaner opens again to achieve reference conditions. You can check the temperature of the gas released by the vacuum cleaner
Configuration list:
| Name | Quantity | Paramount |
| Test bench | 2 | Standard profile structure |
| Normal inflatable room | 1 | Conforms to IEC60312 460mm*250mm*460mm stainless steel 5mm thickness |
| Comprehensive performance tester | 1 | Test accuracy 0.5 |
| Vortex Flowmeter | 1 | Range: (0.5~5) CBM/min accuracy : ±1% With temperature and pressure compensation |
| Pressure transmitter | 1 | Range: 0— - 50Kpa accuracy: ±0.5% With temperature and pressure compensation |
| Electric valve control system | 1 | Step control 15 point data sampling, use unequal algorithm |
| Test control cabinet | 1 | Electric integrated control circuit, manual test adjustment button |
| Air switch, cable | 1 | With over-current protection, stop button |
| Vacuum cleaner made of the whole machine | 1 | Conversion aperture 32mm, 35mm, motor diameter to be provided |
| testing software | 1 | Corrected IEC60312 by European standard 5.2.8.4 |
| System PC | 1 | DELL 660, dual core CPU, 2G memory, 500G hard disk |
| Printer | 1 | HP100 |
Pictures for reference :


|