| Sign In | Join Free | My futurenowinc.com |
|
| Categories | PSA Nitrogen Generator |
|---|---|
| Brand Name: | True |
| Model Number: | TY |
| Certification: | CE,ISO |
| Place of Origin: | Jiangyin,Jiangsu China |
| MOQ: | 1 set |
| Price: | as negotiate |
| Supply Ability: | 20 sets per month |
| Delivery Time: | 35 days |
| Packaging Details: | wooden case packing |
| Application:: | Furance protection |
| Color:: | As required |
| CE passed:: | Yes |
| Material:: | Carbon,stainless steel |
| After service:: | Yes |
| Air compressor:: | Equip |
| Company Info. |
| Jiangsu Tongyue Gas System Co.,Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
PSA nitrogen by pressure swing adsorption,separation oxygen or nitrogen from air.
4 Product classify and specification
Product classify and specification according to chart 1
Chart 1
Product classify | Specification(output) m3/h |
| Oxygen generator | 5, 10, 25, 50, 100, 150, 200, 300, 500, 600, 800, 1000, 1200, 1500, 1800, 2000, 2500, 3000, 4000, 5000, 6000, 7000, 8000, 9000, 10000, 12000, 15000 |
| Nitrogen generator | 5, 10, 25, 50, 100, 150, 200, 300, 500, 600, 800, 1000, 1200, 1500, 1800, 2000, 2500, 3000, 4000, 5000 |
| Remark:The specification can add according to requirements | |
5 Technical requirements
5.1 Design condition:
a) Equipment design according to Reference atmosphere condition chart 2
Chart 2
| Description | Requirements |
| Mpa | 0.101325(absolute pressure) |
| Temperature ℃ | 0 |
| relative humidity % | 75 |
b)Material air according to chart 3
Chart 3
| Description | Permissible limit content |
| 30 |
| CO2(volume fraction, 10-6) | 400 |
| C2H2(volume fraction, 10-6) | 0.5 |
| CnHm(volume fraction, 10-6) | 30 |
| Oil content(volume fraction, 10-6) | 0.01 |
Σ(NOX+SO2+HCl+Cl2) | 8 |
c) Cooling water according to chart 4
d) instrument gas should clean and dry, gas source pressure range and quality should according to GB/T 4830
e) Power is alternating current ,voltage,phase position and current according to chart 5. Other technical condition should according to GB/T 12325

|