Isolating Switch For Power Station GW1 12KV
Description:
1. Simple Structure, reliable property, wide usage, economical and
long-time life.
2. Complete specification and satisfy user's different parameters
requirements.
3. Connecting terminal and the electric pole is made by casting
aluminum-alloy and section bar, having the good property of
high-intensity, good flowing and anti-corrosion
4. In the galvanic circle, the section is the combination structure
made by screw fix linking, having the good property of stable
flowing, high reliability, simple change way and convenient adding
volume way.
5. In the galvanic circle, the contact and finger is made by T2Y
pure copper tap whose connecting part is coated by 30μ M silver.
6. Finger spring is made by the stainless steel and its design is
the inside hiding and outside press structure which is convenient
for testing and changing.
7. Bearing block is made by high-intensity casting steel (disposed
by hot zinc coating), the height can be adjusted and have the
function of damping.
8. All the operating rod and linking rod are supplied by
manufacturer, which is convenient for loading, adjusting and
testing.
9. Can be supplied as a whole above the ground according to user's
requirement.
Specifications:
| Items | Technical parameter | |||
| NO | Type | GW1-10 | GW1-15 | GW1-20 | 
| 1 | Rated Voltage kV | 10 | 15 | 20 | 
| 2 | Max working voltage kV | 12 | 17.5 | 24 | 
| 3 | Rated frequency Hz | 50 | ||
| 4 | Rated current A | 400 | 630 | 1250 | 
| 5 | Rated Short Time withstand current and Time kA/s | 20/4 | 25/4 | 31.5/4 | 
| 6 | Rated Peak withstand current kA | 50 | 63 | 80 | 
| 7 | 1min power frequency withstand voltage (effective value) kV | To earth | 42 | 45 | 
| To phase | 53 | 55 | ||
| 8 | Lightning Impulse wishstand voltage(peak value) KV | To earth | 75 | 105 | 
| To phase | 85 | 120 | ||
|   | 
 Medium Voltage Three Post Outdoor Electric Isolator Switch GW1-10
                                                                                    
                        
                        
                        
                                                            Medium Voltage Three Post Outdoor Electric Isolator Switch GW1-10
                                                    
                        
                     Outdoor 12KV 400A Three Post Low Voltage Isolator Electric AC Isolation Switch
                                                                                    
                        
                        
                        
                                                            Outdoor 12KV 400A Three Post Low Voltage Isolator Electric AC Isolation Switch
                                                    
                        
                     12KV Medium Voltage Vertical Break Disconnect Switch Isolator
                                                                                    
                        
                        
                        
                                                            12KV Medium Voltage Vertical Break Disconnect Switch Isolator
                                                    
                        
                     10KV 1.6KA Medium Voltage Disconnect Switch Elelctronic Isolator GW9-15
                                                                                    
                        
                        
                        
                                                            10KV 1.6KA Medium Voltage Disconnect Switch Elelctronic Isolator GW9-15
                                                    
                        
                     Polymer Composite Post Low Voltage Isolator Disconnect Switch HGW9-10
                                                                                    
                        
                        
                        
                                                            Polymer Composite Post Low Voltage Isolator Disconnect Switch HGW9-10
                                                    
                        
                     Three Phase 15KV 630A Medium Voltage Load Disconnector GW1-15
                                                                                    
                        
                        
                        
                                                            Three Phase 15KV 630A Medium Voltage Load Disconnector GW1-15
                                                    
                        
                     Centre Break Two Post Low Voltage Isolator Three Phase Isolation Switch Horizontal Operate
                                                                                    
                        
                        
                        
                                                            Centre Break Two Post Low Voltage Isolator Three Phase Isolation Switch Horizontal Operate
                                                    
                        
                     Normally Type Substation Low Voltage Disconnect Switch Manual Mechanism 12KV
                                                                                    
                        
                        
                        
                                                            Normally Type Substation Low Voltage Disconnect Switch Manual Mechanism 12KV
                                                    
                        
                     Outdoor Medium Voltage / Low Voltage Isolator Switch for Power Station
                                                                                    
                        
                        
                        
                                                            Outdoor Medium Voltage / Low Voltage Isolator Switch for Power Station
                                                    
                        
                     High Intensity GW4 Low Voltage Isolator Switch With Disconnect Terminal
                                                                                    
                        
                        
                        
                                                            High Intensity GW4 Low Voltage Isolator Switch With Disconnect Terminal