| Sign In | Join Free | My futurenowinc.com |
|
| Categories | Corrosion Test Chamber |
|---|---|
| Brand Name: | ASLI |
| Model Number: | SH-90 |
| Certification: | CE,Calibration report |
| Place of Origin: | China, DongGuan |
| MOQ: | 1 unit |
| Price: | Negotiation |
| Payment Terms: | T/T, Western Union |
| Supply Ability: | 100 sets per month |
| Delivery Time: | 7~15 workdays |
| Packaging Details: | Strong plywood case |
| Internal Dimension: | W900xD600xH500MM |
| External dimension: | W1400xD900xH1200MM |
| Test: | corrosion test, Salt spray test |
| Test Volume: | 90 Liters |
| Material: | PVC Cover |
| Power: | AC220V, Singal Phase |
| Service: | Customized |
salt spray test chamber SH-160.pdf
CE Approved Salt Spray Corrosion Test Chamber with Calibration Report
Model No.: SH-90
Internal Dimension:W900xD600xH500MM;
External dimension:W1400xD900xH1200MM
Material:
1.Test chamber material :PVC board
2.The chamber sealed by impact-resistany acrylic board.
3.Saturated air barrels:SUS304 stainless steel(excellent high
temperature& high pressure resistant performance)
Constant temperature control settable:
(A)Salt Spray Test: NSS,ACSS
1.testing zone temperature : 35℃(+/-)2℃
2.Saturated air barrels temperature : 47℃(+/-)2℃
(B)Corrission resistance test:
1.Laboratory: 50℃(+/-)2℃
2.Saturated air barrels: 63℃(+/-)2℃

Air supply system:
"1.Air pressure is 1 kg/cm2, divided into two sections adjustment"
"2.First step is rough adjustment : 2 kg/cm2 imported type air
filter with drainage function, the second step is precision
adjustment : 1 g/cm2 Pressure gauge"
Spray fog method:
1.Adopt Knut principle to absorb brine to atomization, uniform
atomization degree, to ensure continuous testing standard.
2.Fog Spray quantity: adjustable type 1-2ml(ml/80cm2/h) (average
quantity of 16 hours)
3.Spray method: continuous spray.
Heating system
Adopting the direct heating mode, fast heating, reduce the standby
time, when the temperature reaches ,the ON/OFF switch shift
automatically,temperature precision, less power consumption.
Control System:
1.Test Chamber temperature controller 0 ~ 99.9 ℃, LCD display with
Dual digital display
, with P.T.D automatic calculation function, temperature deviation
± 0.3 ℃
2.Saturated air barrel temperature controller 0 ~ 99.9 ℃, LCD
display with Dual digital display, with P.I.D automatic calculation
function, error of the temperature control in ±0.3 ℃
3.timmer : 0~9990hr
4.Digital controller:0.1s~9990hr
5. air pressure range of the gauge: 0~5kg/cm2
6.temperature senser
7.electromagnetic valve
8. electric relay
Water system:
Adopting automatic adding water supplement system, automatically
added, when the water level is too low
Safety Protection Device:
automatic power cut off supply device while water level is too low
automatic power cut off supply device for over temperature
alarm light device
Standard comply:
This system conforms to the salt spray test of the reliability test
specification:
ASTM B-117,B-368,D-380, JIS D-0201,D-0205,H-8681,CNS
C-6014,H-2040,Z-8026, MIL,NACE,IEC,DIN,SAE

|