chinacoal05
Product Introduction
*Automated gain,Peak Hold and Peak Memory;
*Automated display precise flaw location(Depth d,level p,distance s,amplitude,sz dB,);
*Ten independence setup, any criterion can be input freely, we can work in the scene without test block;
*Big memory of 300 A graph and 30000 thickness value.
*Gate and DAC alarm;Acoustic-Optical alarm;
*RS232 port,communication with pc is easy;
*The embeded software can be online updated;
*Li battery, continue working time up to 7 hours;
*Other assistant function;
*Display freeze;
*Automated echo degree;
*Angles and K-value;
*Lock and unlock function of system parameters;
*Dormancy and screen savers;
*Electronic clock calendar ;
*Two gates setting and alarm indication;
*High-speed capture and very low noise;
*DAC,AVG; Solid metal housing (IP65);
*Provides high contrast viewing of the waveform from bright, direct sunlight to completae darkness and easy to read from all angles;
*Powerful pc software and reports can be export to excel;
Main Parameter
Designation  | Technical Data  | 
Range of scanning (mm)  | Range of scanning (mm):2.5~60000(Steel Longitudinal wave)  | 
D-delay (ms)  | D-delay (ms):-20~+3400 Steps: -20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600, 700,800,900,1000,1500,2000,2500,3000,3400. Adjusting steps: 0.1(-20ms~999.9ms),1(1000ms~3400ms)  | 
P-delay (ms)  | P-delay:0.0~99.99 Adjusting steps: 0.01  | 
MTLVEL(m/s)  | MTLVEL:1000~9999 7 fixed levels: 2260,2730,3080,3230,4700,5920,6300 Adjusting steps:1  | 
Working mode  | Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission(transmission probe)  | 
FrequencyRange (MHz)  | 0.4–20  | 
Gain adjustment (dB)  | 0~110 Adjusting step: 0.0,0.2,0.5,1,2,6,12  | 
Reject  | 0%~80% of screen height, step: 1%  | 
Vertical linear error  | Vertical linear error is not more than 3%  | 
Horizontal linear error  | Not more than 0.2% in the scanning range  | 
Sensitivity Leavings  | ≥62 dB  | 
Dynamic range  | ≥32dB  | 
Alarm  | Three modes, i.e. forbidden wave, loss wave and auto  | 
Monitoring door  | 2, expressed by bold transverse line, whose start, width and height are adjustable. Adjusting range of start (mm): horizontal pixel 0~208, the displayed value is relative with the scanning range. Step: value in mm corresponding to a pixel (relative with the scanning range) Adjusting range of width (mm): horizontal pixel 4~212, the displayed value is relative with the scanning range. Step: value in mm corresponding to a pixel (relative with the scanning range) Adjusting range of height: 2%~90% of vertical graduation Step graduation: 1%  | 
Display  | Display: high-brightness lattice  | 
A-Scan display area  | Full screen or local A-Scan display freezing and de-freezingA-Scan filling  | 
Data save  | 300 A-Scan images (including setting of instrument) 30000 values of thickness (300 sets)  | 
Standard interface  | RS232 for communication with PC  | 
Measuring unit  | mm/inch  | 
Battery  | Li battery 4×3.6V4800mAh  | 
Power adaptor  | Input 100V~240V/50Hz~60Hz Output 9V~12VDC/1.5A  | 
Working temperature  | -20°C~70°C  | 
Working humidity  | 20%~90%  | 
Port type  | BNC  | 
Dimension (mm)  | 240×180×50  | 
Weight (kg)  | 1.8  | 
                                 
                             |