Categories Power Connectors
Brand Name: PX0575/20/63
MOQ: 400
Model Number: PX0575/20/63
Stock: 386
Description: Power Entry Modules (PEM) RoHS
Packaging Details: -
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Bulgin PX0575/20/63

Product Overview

This comprehensive range of IEC connectors, conforming to IEC and EN 60320 specifications, offers quality mains-rated inlets, outlets, and connectors suitable for a wide array of mains-powered equipment and cable applications. With electrical ratings up to 20A and 250V (UL), these connectors are available in various mounting styles and termination options, including flange fixing, snap-to-panel, PCB mounting, and different tab and screw terminal types. Accessories such as insulating boots, retaining clips, and safety covers are also available. Most styles are offered in standard black, white, or grey, with special colors available to match OEM equipment, subject to product approval.

Product Attributes

  • Standards: IEC 60320, EN 60320
  • Approvals: UL, CSA, VDE, ENEC
  • Mouldings: Nylon, Flammability Rating UL94V-0
  • Contacts: Brass, Clean / Nickel Plated / Tin Plated
  • Available Colors: Black (Standard), White, Grey, Special Colors (subject to approval)
  • RoHS Compliant: Yes

Technical Specifications

Product Type / StandardModel / Sheet No.Fixing TypeTermination TypeCurrent RatingVoltage RatingMax. Plug TemperatureOperating Temperature RangeContact ResistanceInsulation ResistanceAC Breakdown
IEC 60320-1 (C14)PX0579, PX0580, PX0590, PX0596, PX0575, PX0595, PF0001, PF0002, PF0030, PF0033, PX0575/10/28, PX0575/10/PC, PX0580/28, PX0579/28, PX0580/PC, PX0580/PC/7, PF0001/48, PF0001/PC, PF0002/28, PF0030/28, PF0030/PC, PF0033/10/28Flange Fixing, Snap to Panel, PCB Mounting2.8/4.8/6.3mm Tabs, Screw Terminals, PC Spills10A250V AC (UL/CSA: 15A, 250V AC)+70C-40C to +70C<10m>10 M5kV (Contact-Contact), 4kV (Contacts-Panel/Accessible Parts)
IEC 60320-1 (C14) - FusedPF0001, PF0002, PF0030, PF0033, PF0006, PF0007, PF0011, PF0016Flange, Snap to Panel, PCB MountingTabs, Screw Terminals, PC Spills10A250V AC+70C-40C to +70C<10m (<15m incl. Fuseholder)>10 M5.5kV (Contact-Contact), 4kV (Contacts-Panel)
IEC 60320-1 (C14) - Twin FusedPF0030, PF0033Flange, Snap to PanelTabs, PC Spills10A250V AC+70C-20C to +70C<15m (per Contact)>10 M6kV (Contact-Contact), 5kV (Contacts-Panel)
IEC 60320-1 (C13, C15, C19)PX0587, PX0588, PX0597, PX0587/SE, PX0585, PX0686, PX0686/SE, PX0685Cable Mounting, Side Entry, Right AngleScrew Terminals10A, 16A250V AC+70C-40C to +70C<10m>10 M / >10 M4kV to 6kV
IEC 60320-1 (C15 & C16) - Hot ConditionPX0597, PX0590, PX0595Flange Mount, Snap Fit to PanelTabs, Screw Terminals10A250V AC (UL/CSA: 15A, 250V AC)+120C-40C to +70C<10m>10 M4.5kV to 10kV
IEC 60320-1 (C18) - Class IIPX0690, PX0691, PX0705, PX0725Flange Mount, Snap Fit to PanelTabs, Screw Terminals, PC Spills10A250V AC (UL/CSA: 15A, 250V AC)+70C-40C to +70C<10m>10 M4kV to 10kV
IEC 60320-1 (C18) - Class II FusedPF0006, PF0007, PF0016Flange Mount, Snap Fit to PanelTabs10A250V AC+70C-40C to +70C<10m (<15m incl. Fuseholder)>10 M5.5kV (Contact-Contact), 4kV (Contacts-Panel)
IEC 60320-2-2 (F) - Class IPX0716, PX0675, PX0695, PX0783, PX0793, PX0793/1Snap Fit to Panel, Flange Mount, PC Flange Rear MountTabs, Screw Terminals, PC Spills10A250V AC (UL/CSA: 15A, 250V AC)+70C-40C to +70C<10m>10 M4kV to 9kV
IEC 60320-2-2 (H) - Class IIPX0705, PX0725Flange Mount, Snap Fit to PanelTabs, PC Spills10A250V AC (UL/CSA: 15A, 250V AC)+70C-40C to +70C<10m>10 M4kV to 9kV
IEC 60320-1 (C19 & C20) - Class IPX0599, PX0596, PX0598Cable Mounting, Flange Mount, Snap Fit to Panel6.3mm or 4.8mm Tabs, Screw Terminals16A250V AC (UL/cUL: 20A, 250V AC)+70C-40C to +70CN/A>5M / >10 M1.5kV AC to 3kV AC

Accessories

Accessory TypePart NumberDescriptionCompatible Products
Retaining ClipKT0006Prevents accidental removal of connector.PX0580 + PX0587, PX0590 + PX0597, PX0690 + PX0587, PX0675 + PX0686, PX0793 + PX0686, PX0793/1 + PX0686
Retaining ClipKT0009Prevents accidental removal of connector. Fits fused flanged inlets.PF0001 + PX0587, PF0001/PC + PX0587, PF0002 + PX0587, PF0030 + PX0587
Retaining ClipKT0012Prevents accidental removal of connector.PX0596 + PX0599
Blanking CoverPNo 14228Protects front of outlet connector. Protects against accidental electric shock.PX0578, PX0675, PX0695, PX0783, PX0793, PX0716
Insulation BootPNo 14340Protects rear of connector. Protects against accidental electric shock.PS20, PS21, PS25, PS26
Insulation BootPNo 14317Protects rear of connector. Protects against accidental electric shock.PF0030, PF0033 (except /PC versions)
Insulation BootPNo 11328Protects rear of connector. Protects against accidental electric shock.PX0575, PX0579, PX0580, PX0590, PX0595
Insulation BootPNo 11987Protects rear of connector. Protects against accidental electric shock.PF range (PF0001, PF0002, PF0006, PF0007, PF0011, PF0016 - Except /PC versions)
Insulation BootPNo 12075Protects rear of connector. Protects against accidental electric shock.PX0675, PX0695, PX0705, PX0725, PX0783, PX0793, PX0793/1 (Except /PC versions)