| 1 - RATING | DC Voltage / Current | - | 30V / 0.5A |
| 2 - OPERATING TEMPERATURE RANGE | Operating | - | -20C ~ 70C |
| Preservative | - | -15C ~ 35C |
| 3 - ELECTRICAL PERFORMANCE | Contact Resistance | DC 5V, 0.1A (Average of 3 successive measurements) | 50m max |
| Insulation Resistance | DC 250V, 1 min (Between terminals and frame) | 100M min |
| Dielectric Strength | AC 250V, 1 min (Between terminals and frame) | Without damage, arcing, or breakdown |
| 4 - MECHANICAL PERFORMANCE | Insertion and Extraction Force | - | 3-30N |
| Terminal Strength | Static load of 10N (1000gf) applied to tip for 60 sec. in any
direction | Without damage or excessive looseness |
| STANDARD ATMOSPHERIC CONDITIONS | Ambient Temperature | - | 15C to 35C |
| Relative Humidity | - | 25% to 75% RH |
| Air Pressure | - | 80Kpa to 106Kpa |
| 5 - DURABILITY | Soldering Heat Test | Wave soldering: 260 5C, within 3 seconds. Hand welding: 380C max,
within 3 seconds. | Electrical characteristics shall be satisfied. |
| Life Test | 5000 cycles at a speed of 30 cycles/min | Contact resistance 200m max. Mechanical and electrical
characteristics shall be satisfied. |
| Heat Test | 852C for 96 hours, then keep in normal condition for 60 minutes. | No damage on appearance, mechanical and electrical characteristics. |
| Humidity Test | 402C, 90-96% RH for 96 hours, then keep in normal condition for 60
minutes. | No damage on appearance, mechanical and electrical characteristics. |
| Cold Test | -253C for 96 hours, then keep in normal condition for 60 minutes. | No damage on appearance, mechanical and electrical characteristics. |
| Salt Spray Test | 5% NaCl solution for 24 hours, then wash. | Without excessive corrosion or crack in appearance. |