| Current Rating | 60A max per contact | EIA-364-70A: 1998 |
| Dielectric Withstanding Voltage (Sea Level) | 3,000V AC for 1 minute | EIA-364-20C, Method B |
| Dielectric Withstanding Voltage (Altitude 70,000ft) | 500V AC for 1 minute | EIA-364-20C, Method B |
| Voltage Rating | 1,500V DC or AC peak | |
| Contact Resistance | 2m max | EIA-364-23B, pre- and post-conditioning |
| Insulation Resistance | 10G min at 1,000V | EIA-364-21C |
| Creepage Distance (Male PCB Vertical) | 5.5mm | See Appendix 3 |
| Creepage Distance (Female & Male Cable) | 17.54mm | See Appendix 3 |
| Clearance Distance (Male PCB Vertical) | 3.64mm | See Appendix 3 |
| Clearance Distance (Female & Male Cable) | 2.7mm | See Appendix 3 |
| Operating Temperature Range | -65C to +150C | |
| Vibration | 10Hz to 2,000Hz, 1.52mm pk-pk displacement or 20gn pk (whichever is
less), 198m/s (20G), 12 cycles per axis, 20 minutes per cycle | EIA-364-28D, Condition IV |
| Mechanical Shock | 981m/s (100G) for 6ms in all axes | EIA-364-27B, Condition C |
| Thermal Shock | -65C to +150C, 10 cycles, 30 mins each extreme | EIA-364-32C, Condition IV |
| Temperature Life | +150C for 1,000 hours | EIA-364-17B, Method A |
| Humidity | 90-95% RH at +40C, 96 hours | EIA-364-31B, Condition A |
| Salt Spray | 24 hours at +35C, concentration 5% | EIA-364-26B |
| Durability | 250 operations | EIA-364-09C |
| Insertion Force (per contact, initial) | 50N max | EIA-364-13C |
| Insertion Force (per contact, post conditioning) | 70N max | EIA-364-13C |
| Withdrawal Force (per contact) | 3N min | EIA-364-13C |
| Contact Retention Force | 35N min per contact | EIA-364-29C |
| Screw-lock Torque | 22-25cmN | |
| Cable Contact Compatibility | 8AWG cable | |
| Materials (Contact) | Beryllium Copper, Gold over Nickel | |
| Materials (Contact Latching Collar) | Cupro-Nickel, 100% Tin over Nickel | |
| Materials (Potting Compound) | Stycast 2651MM with Catalyst 9 | |