| Sign In | Join Free | My futurenowinc.com |
|
| Categories | Patient Monitor Parts |
|---|---|
| Brand Name: | Biocare |
| Model Number: | FM-801 |
| MOQ: | 1 Piece |
| Price: | USD |
| Payment Terms: | T/T,Western Union,Paypal |
| Delivery Time: | 3-5 working days |
| Packaging Details: | Carton |
| Product Name: | Interface board |
| PN: | 02047015-01 50205008-01 |
| Condition: | Used |
| Signal transmission rate: | ≤100Mbps |
| Material: | PCB substrate: FR-4 epoxy glass cloth |
| Delivery Method: | By DHL or FedEx |
| Color: | Green |
| Package: | Carton |
| Size: | 100mm×60mm×1.6mm |
| Weight: | About 50g |
| Company Info. |
| China World Technology Medical Equipment Service Group |
| Verified Supplier |
| View Contact Details |
| Product List |
Biocare FM-801 Fetal Monitor Interface Board has two models: Side A and Side B, model numbers 02047015-01 and 50205008-01, respectively.
Different sides face different signal sources and have different functions.
Side A, model number 02047015-01, is the internal interface board, connecting to the main board and receiving and transmitting signals from it. It acts as a signal relay station, helping the main board organize signals and ensure orderly operation.
Side B, model number 50205008-01, primarily connects to external interfaces such as USB and Ethernet, responsible for transmitting monitoring data from the device to external devices and other uses.
Both sides of the interface board offer diverse functions, making them a valuable companion to the main board.
The 02047015-01 centrally manages and transmits fetal heart rate/contraction waveform data and alarm signals output by the main board to the main board, improving internal signal management.
50205008-01 implements data exchange and export functions, enabling online query and transmission of electronic medical records.
Both interface boards feature reserved expansion channels for internal and external expansion. Internally, they can connect to a fetal heart rate playback module and a fetal movement marker module; externally, they can connect to a barcode scanner for automatic patient information entry and printer connection.
The interface board's "middle layer" design isolates faults and protects core components.
| Product name | Interface board |
|---|---|
| PN | 02047015-01 50205008-01 |
| Compatible machine | Biocare FM-801 |
| Condition | Used |
| Signal transmission rate | ≤100Mbps |
| Material | PCB substrate: FR-4 epoxy glass cloth |
| Color | Green |
| Size | 100mm*60mm*1.6mm |
| Weight | About 50g |
| Connections | 20-pin/16-pin gold-plated cable |


A1: It's most likely a problem with the LVDS signal transmission on the 02047015-01. After turning off the power, first check the LVDS cable for oxidation and looseness. Reseat it and then measure the LVDS signal output pins on the interface board (seek professional assistance). If there is no signal output, the interface board's signal conditioning circuit is faulty. If there is a signal but no display, and all cables are connected properly, the 02047015-01 interface board needs to be replaced.
A2: It's most likely a problem with the interface board's USB circuitry or driver. If there's no physical damage to the USB port, the interface board's USB controller chip is faulty, and the 50205008-01 needs to be replaced.
A3: It could be a problem with the Ethernet circuit. If the wiring is normal, check the Ethernet port's power supply voltage. If there is no voltage, the interface board's power supply circuit is faulty. If the voltage is normal, measure the continuity of the Ethernet port on the interface board. If there is no continuity, the Ethernet chip on the interface board is damaged and the 50205008-01 interface board needs to be replaced.
| Payment Methods | Bank Transfer / PayPal / Western Union |
|---|---|
| Shipping Methods | DHL / FedEx |
|