| Sign In | Join Free | My futurenowinc.com |
|
| Categories | Differential Pressure Transmitter |
|---|---|
| Mounting Method: | DIN rail or wall mount |
| Electric Connector: | Cable, connector and optional |
| Port: | Shenzhen Port |
| Safety Grade: | IP65 |
| Protection Class: | IP65, IP67 |
| Operating Temp: | -30~80℃ |
| Power Supply: | 24 VDC |
| Nominal Pressure: | (0.25-42) MPa |
| Communication Protocol: | HART |
| Sensor Type: | Capacitive |
| Company Info. |
| Baoji Hengtong Electronics Co., LTD |
| Verified Supplier |
| View Contact Details |
| Product List |
BP93420DI Differential Pressure Transmitter
Introduction:
BP93420DI is a Micro-differential pressure transmitter that
utilizes the piezoresistive effect of semiconductor silicon
material to convert differential pressure into an electrical signal. It is mainly used for measuring small
differential pressures of non-corrosive dry gases, suitable for
applications in industries such as boiler air supply, underground ventilation in the power and mining industries,
and pressure automatic detection in ultra-clean workshops for
process control.
Product Features:
Applications:
| Performance Parameters | |
| Measurement Range | 0-500Pa, 0-1KPa,0-2KPa, 0-5KPa, 0-7kPa, 0-10KPa,0~~~200KPa |
| Pressure Type | Differential Pressure |
| Static pressure | 2 times of the rated range |
| Overload | ≤ 1.5 times of the rated range |
| Accuracy @ 25ºC | ±0.5% (Typical), ±1% (Maximum) |
| Zero Temperature Drift | ±2.5%F.S/ºC(Typical) ±3%F.S/ºC(Maximum) |
| Span Temperature Drift | ±2.5%F.S/ºC(Typical) ±3%F.S/ºC(Maximum) |
| Compensation Temperature | 0-50ºC |
| Operating Temperature | -20ºC~80ºC |
| Storage Temperature | -40ºC~100ºC |
| Housing Material | Aluminum alloy,Plastic |
| Relative humidity | 0-80% |
| Pressure connection | φ6 air nozzle or customizable |
| Protection Rating | IP65 |
| Cable material | Polyethylene |
| Weight | ~0.15kg |
| Output Signal | Supply Voltage | Output Type |
| 4~20mA | 12~30VDC | 2/3/4 wire |
| 0~10/20mA | 3 wire | |
| 0/1~5V | ||
| 0/1~10V | ||
| 0.5~4.5V | 5VDC |



| Ordering tips |
1. When selecting the product, please ensure that the medium to be
measured is compatible with the product parts in contact.
2. To ensure reliable operation, ensure that the measured medium is
slowly and evenly pressurized on both the positive and negative
pressure chambers of the transmitter.
3. During installation, it is recommended to position the pressure
interfaces at both ends horizontally to minimize the impact on the
product due to the installation position.
4. For special requirements such as strong vibration, instantaneous
impact force, strong electromagnetic interference, and radio
frequency interference, please inform the company and specify them
in the order.
| Order Guide | ||||||||
| BP93420D | Pressure Transmitter | |||||||
| Code | Outline Construction | |||||||
| I | Differential Pressure Transmitter | |||||||
| Measurement Range | 0-500Pa, 0-1KPa,0-2KPa, 0-5KPa, 0-7kPa, 0-10KPa,0~~~200KPa | |||||||
| Code | Power Supply | |||||||
| D1 | 24VDC | |||||||
| D2 | 5VDC | |||||||
| D3 | Other | |||||||
| Code | Output Signal | |||||||
| S1 | 4~20mADC | S5 | 0~20mADC | |||||
| S2 | 1~5VDC | S6 | 0~10VDC | |||||
| S3 | 0~5VDC | S7 | 0.5~4.5VDC | |||||
| S4 | 0~10mADC | |||||||
| Code | Pressure Type | |||||||
| D | Differential Pressure | |||||||
| Code | Housing Material | |||||||
| 01 | Aluminum alloy | |||||||
| 02 | Plastic | |||||||
|