Sign In | Join Free | My futurenowinc.com
futurenowinc.com
Products
Search by Category
Home > Temperature Instruments >

GC-7850 PLUS Gas Analyzer

Categories Gas Analysis
Place of Origin: China
Certification: CE
MOQ: 1
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

GC-7850 PLUS Gas Analyzer

GC-7850 PLUS Gas Analyzer

Product Specifications

Temperature control5 temperature control points, 5-450 ℃ above room temperature , accuracy of 0.1 ℃ ;
Overtemperature protectionIf any circuit exceeds the protection temperature, heating will stop automatically to avoid damage to the instrument caused by overheating;
External events5-way external event control, 8 actions, 0.1-9999.99 seconds arbitrarily set, and can work in cycles;
Detection principleTCD detector , sensitivity S ≥ 5 000mv.ml/mg (benzene)
Carrier gas typeBuilt-in high-purity hydrogen production device, hydrogen purity ≥ 99.995% , pressure 0.3MPA;
Operation ModeAUTOGC host computer return control operation, detection times 1, 2, 3 optional ;
Injection valveElectric injection valve 6 -way /8-way/10-way/12-way optional
InletMiddle hole 3.1-M8*1 interface and pagoda interface dual use
Sampling deviceLatex bladder /rubber bladder/aluminum foil air bag
Content calculationYes (volume percentage)
Calorific value calculationYes (Unit : Kcal or MJ )
Gasification rateYes (applicable to LNG, liquid nitrogen, liquid argon)
Gas densityYes (for all gases)
Liquid densityYes (only applicable to LNG, liquid nitrogen, and liquid argon)
Sample gas pressure0.05-0.3Mpa
Intake requirementsDust-free, water-free, oil-free
Sample gas flow≤5000mL/min
Measuring range0-100%
Resolution0.00 0 1%
Detection error≤±0.1%
Qualitative error≤0.02min
Warm-up time≤30min
Analysis cycleAbout 15 minutes
Sampling pump500ml/min
Power supplyAC220V±10%
Work EnvironmentTemperature: 5 ℃-60℃ Humidity : 10%-85%
Dimensions420mm×370mm× 460mm (width*height*depth)
weightAbout 25 kg

Overview

This system is widely used across the natural gas and energy industries, including LNG/CNG refueling stations, gas transportation companies, gas storage facilities, coal-to-gas enterprises, LNG peak-shaving stations, associated petroleum gas, coalbed methane, mine gas, shale gas, gas pipeline transportation companies, gas appliance manufacturers, petrochemical refineries, coking plants, smelters, and gas supply stations. With high-precision analysis and stable performance, it provides reliable data support and safety assurance for gas composition monitoring, safety inspection, and process control.

Features & Benefits

  • This machine has a reasonable design and compact layout. It is an analytical instrument that integrates gas source, power supply, electric injection valve, analytical column, detector, signal acquisition card and Intel processor.
  • All parameters are set on the computer and have power-off memory function ;
  • Built- in 24-bit high-precision digital-to-analog conversion ; directly outputs digital signals to avoid loss and distortion of analog signals during transmission;
  • Using standard Modbus RTU transmission protocol, the analysis results can be connected to DCS (distributed control system)
  • 5-way temperature control: 5 degrees above room temperature - 450℃, increment of 0.1℃; each channel has over-temperature protection function. If any channel exceeds the protection temperature, the CPU will automatically stop heating to avoid damage to the instrument caused by overheating.
  • 5 external events, 8 actions, 0.1-9999.99 seconds; detection times 1, 2, 3 optional
  • Using an isolated power supply data acquisition card, the two channels do not interfere with each other, can operate synchronously or asynchronously , and can be grafted onto each other's spectra, with analysis results displayed on a single spectrum. The analysis software automatically calculates the content of the detected gas components, as well as related indicators such as higher calorific value, lower calorific value, density, relative density, and vaporization rate. It can also automatically generate a TXT file for third-party access.
  • Three-dimensional annular heating, uniform heating and small temperature gradient;
  • Double column box design: each column box can be temperature-controlled independently without interfering with each other;
  • Two thermal conductivity detectors (double-arm tungsten filaments) can be installed simultaneously to collect detector data;
  • Built-in diaphragm sampling pump to avoid detection errors caused by squeezing the bladder by hand;
  • Automatically generate a test report showing the test results at 0℃ and 20℃;
  • Unlimited database, allowing analysis and comparison of historical data.
  • Can be equipped with mouse, keyboard and printer.
GC-7850 PLUS Gas Analyzer
Quality GC-7850 PLUS Gas Analyzer for sale
Send your message to this supplier
 
*From:
*To: Beijing HiYi Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0