Categories Single Phase Pad Mounted Transformer
Brand Name: WINLEY
Model Number: ZGD-167/12.47
Certification: UL/cUL, ISO
Place of Origin: CHINA
MOQ: 1unit
Price: $1000-$10000
Payment Terms: T/T
Supply Ability: 1000set/month
Delivery Time: 30days
Packaging Details: Plywood case
Type: Liquid Filled Pad Mounted Transformer
Capacity: 167Kva
Feed Type: Loop Feed
Primary Voltage: 12470GrdY/7200
Secondary Voltage: 240/480V
Cooling Class: ONAN; Self-Cooled
Frequency: 60Hz
Efficiency Standard(s): Meets DOE 2016 Standards, Meets ANSI/IEEE Standards
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

UL/cUL Listed 167Kva Single Phase Pad Mounted Transformer Liquid Filled 12470V To 240V Meet DOE 2016 Standard

UL/cUL Listed 167Kva Single Phase Pad Mounted Transformer Liquid Filled 12470V To 240V Meet DOE 2016 Standard


Product Features


  • Primary / Secondary: 12470Y/7200V Grounded Wye primary; 240/480V single‑phase secondary
  • Type: Liquid‑filled pad‑mounted, ONAN (self‑cooled)
  • Capacity / Performance: 167 kVA, 65°C rise, DOE 2016 efficiency 99.10%
  • Insulation / Fluid: Mineral oil, non‑PCB, 125 gallons
  • Construction: Copper windings with electrostatic shield; tamper‑resistant, pad‑lockable coated steel housing (Munsell green)
  • Connections & Protection: Dead‑front primary with standoff bushings and load‑break elbows; live‑front secondary threaded stud terminals; bayonet fuses; HV surge arrestor; 5‑position (2.5%) tap changer
  • Standards & Specs: Meets ANSI/IEEE and ASTM standards, 55 dBA, ~1950 lb, bottom feed conduit entry


Main data


Transformer TypePad Mounted, Compartmental-Type
Transformer ConfigurationLiquid Filled Pad Mounted
Transformer Feed TypeLoop Feed
PhaseSingle Phase
Capacity167
Primary Voltage12470GrdY/7200
Secondary Voltage240/480V (L-N-L)
Frequency60 Hz
Temperature Rise65°C
Cooling ClassONAN; Self-Cooled
EfficiencyMeet DOE 2016 Standard
Winding MaterialCopper
Ambient Temperature Rating40°C
Sound Level55 dBA
Efficiency99.10%
No Load Loss (in watts)*+/- 450W
Load Loss (in watts)*+/- 1820W

Technical drawings



Why choose us


1. WINLEY single-phase transformer has obtained UL/cUL certification, with a capacity of 10-333KVA and a voltage of up to 34.5KV
2. The products are designed according to multiple standards and meet or even exceed DOE 2016, IEEE, ANSI, CSA, IEC, NEMA and other standards.
3. The monthly delivery capacity is over 800 units, and fast delivery can be achieved within 4 weeks.


【UL Listed】



【cUL Listed】


Specification


Single phase Pad mounted Transformer Specification
RatingHigh voltage(kV)No Load LossOn load LossHeightDepthWidthOil Weight(kg)Total Weight(kg)
(kVA)(mm)(mm)(mm)
15 kVA34.5/19.92
13.8/8
13.2/7.6
12.47/7.2
or others
5019584074061045294
25 kVA8029084074061068362
37.5 kVA10636084076061075476
50 kVA13550084081061093553
75 kVA190650840860610132672
100 kVA28010109101200965230714
167 kVA435153010001200965265913
250 kVA55022301250130014303251106

Production process


FAQ


1. Q: Can I have a sample order?

A: Yes, we welcome sample order to test and check quality.

2. Q: What is the lead time?

A: Mass production time 15-25 days.

3. Q: How long is the warranty?

A: 24 monthes from B/L. If there are any accessory problems,just provide the photos of damaged accessory,then we will provide free service. According to the number of products,we will provide easily damaged accessories for free. we also can provide technical support if you need.

4. Q: Is OEM/ODM available?

A: Yes,it is! We are manufacturer with our own R&D team, we can customize products according to customer's drawing or requirements.

Customized services:

a. Customized color and special function.

b. Customized box.

c. Print customer's logo.

d. Your other ideas about product, we can help you design and put them into production. The above customized services must be confirmed before production.

5. Q: How to control the products quality?

A: Our company owns the core technology ,all kinds of products hold CE certificate. We have professional engineers. Workers are strictly required to make products according to the drawings. Each process has technical instructors.The QC supervisors will regularly inspect the production. We will do products performance tests during production, and comprehensive quality tests when the products is completed.

Quality UL/cUL Listed 167Kva Single Phase Pad Mounted Transformer Liquid Filled 12470V To 240V Meet DOE 2016 Standard for sale
Send your message to this supplier
 
*From:
*To: Xiamen Winley Electric Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0