| Output Current Range: | 1mA -120A (Up to 230A Max) |
| Output Current Power: | 2000VA (Max) |
| Output Voltage Power: | 1000VA (Max) |
| Output Voltage Range: | 24V -288V |
| Voltage Output: Range: | Range: 24V – 288V |
| Current Output Range: | 1mA – 120A (max 230A) |
| Phase Adjustment Range: | 0° – 360° |
| Power Supply: | AC 220V ±10%, 50Hz ±2Hz |
| Company Info. |
| Guangzhou GENY Electric Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
Supports testing for: Active power, Reactive power, Active energy, Reactive energy
Start-up and creep tests
Automatic calibration for fast creep and start-up tests
Measures basic error, average error, standard deviation, and 24-hour variation
Comprehensive influence tests: voltage, frequency, harmonics (2nd–21st), and phase sequence
Simultaneous current measurements on the same meter rack
Test energy meters without disconnecting voltage or current circuits
Built-in protections: current open circuit and voltage short circuit
Integrated optical scanning head greatly improves operational efficiency
Dual operation modes: automatic and manual
PC software for automatic error data processing, storage, and real-time output
Data management functions with customizable report printing
Barcode input supported
Simple and reliable mechanical structure
Configurable meter positions: from 3 up to 60 meters
Forward/reverse active and reactive energy error testing
Time base source SW-5D for measuring daily timing error of energy meters
Communication test and broadcast time synchronization
Constant verification via pulse counting, timing, or start-stop energy method
Load switching test, demand period test, and demand indication error test
Register indication and combined register error testing
Optional: Power consumption test, tilt influence test, prepaid energy meter test
Power Supply: AC 220V ±10%, 50Hz ±2Hz
Operating Temperature: -10°C to +40°C
Humidity Range: 35% to 95%
Range: 24V – 288V
Maximum Output Power: 1000VA
Resolution: 0.01%
Stability: 0.02% / 120s
Load Regulation: 0.01%
Distortion: ≤ 0.3% (within full linear load range)
Range: 1mA – 120A (max 230A)
Maximum Output Power: 2000VA
Resolution: 0.01%
Stability: 0.02% / 120s
Load Regulation: 0.01%
Distortion: ≤ 0.3% (within full linear load range)
Continuous Current Capacity: 100A
Phase Adjustment Range: 0° – 360°
Phase Resolution: 0.01°
Frequency Range: 45Hz – 65Hz
Frequency Resolution: 0.01Hz
Power Output Stability: 0.02% / 120s



|