| Contact Sizes | Size 8, 12, 16, 20 |
| Contact Termination Types | Straight Solder, Compliant Press-in, Right Angle (90) Solder, Crimp
Removable, Solder Cup Removable, Screw Termination |
| Standard Contact Current Rating | Up to 40 Amperes (Size 12), 18 Amperes (PLC30), 25 Amperes (PLB12),
32 Amperes (PLA03) |
| High Conductivity Contact Current Rating | Up to 55 Amperes (Size 12) |
| Initial Contact Resistance (Standard) | 0.0016 ohms max. (Size 16), 0.001 ohms max. (Size 12), 0.0005 ohms
max. (Power Contacts) |
| Initial Contact Resistance (High Conductivity) | 0.0007 ohms max. (Size 16), 0.0007 ohms max. (Size 12), 0.0003 ohms
max. (Power Contacts) |
| Insulation Resistance | 5 G ohms min. |
| Voltage Proof | 2000 V rms (General), 3000 V rms (Safety Shroud), 3750 V rms (Power
Input) |
| Working Voltage | 600 VAC (General), 600 V rms (Safety Shroud), 1250 V rms (Power
Input) |
| Working Temperature | -55C to +125C |
| Mechanical Operations | 500 operations |
| Contact Retention (Removable) | 15 lbs. (Size 16), 20 lbs. (Size 12) |
| Contact Retention (Fixed) | 6 lbs. (Size 16) |
| Dimensional Tolerances | Male contact mating diameters: 0.001 inches [0.03 mm] Contact termination diameters: 0.003 inches [0.08 mm] All other diameters: 0.005 inches [0.13 mm] All other dimensions: 0.015 inches [0.38 mm] |
| Featured Technologies | Large Surface Area (L.S.A.) Contact Mating System, Bi-Spring Power
Press-in Terminations |
| Connection Systems | Board to Board, Board to Cable, Cable to Cable, Cable to Panel
Mount, Panel Mount to Cable |
| Sequential Mating | Available (Male contacts provide multiple mating lengths) |
| Locking System | Integral locking on insulators |
| Mounting Options | Push-on fasteners, Self-tapping screws, Metal/Plastic Right Angle
Brackets, Quick Release Mounting Clips, Fixed Style Mounting Clips,
Blind Mating Systems |
| Available Connector Series | PLA, PLAH, PLB, PLBH, PLC, PLCH, PLS, PLSH, PLB10W2, PLC16W4 |