| Sign In | Join Free | My futurenowinc.com | 
 | 
| Categories | Online Gas Monitoring System | 
|---|---|
| Brand Name: | JUGE | 
| Model Number: | AG-600-A8 | 
| Certification: | IOS9001, CE | 
| Place of Origin: | Nanjing, China | 
| MOQ: | 1 Unit | 
| Price: | USD1000-10000 | 
| Payment Terms: | Online order,T/T | 
| Supply Ability: | 100 Unit/Week | 
| Delivery Time: | 5-8 working days | 
| Packaging Details: | Neutral carton | 
| Product name: | Air Quality Online Monitoring System | 
| Particulate Matter (PM): | PM₂.₅, PM₁₀, PM₁₀₀, TSP | 
| Inorganic Gases: | SO₂, NO₂, CO, O₃, TVOC | 
| Meteorological Parameters: | Temperature, Humidity, Wind Speed, Wind Direction, Atmospheric Pressure | 
| Data Transmission: | 4G transmission; Capable of uploading to data platforms; | 
| Ingress Protection (IP): | IP53 | 
| Power Supply: | AC 220V | 
| Installation Method: | Pole-mounted/Bracket-mounted | 
| Company Info. | 
| Nanjing Juge Environmental Technology Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Grid-based Air Quality Monitoring Micro Station PM2.5 SO2 CO NO2 O3 TVOC Online Gas Monitoring System
>>Overview
High Integration: Can simultaneously integrate sensors for particulate matter, SO₂, CO, NO₂, O₃, TVOC, and meteorological five-parameter sensors.
Optical Sizing: Utilizes optical particle sizing technology for simultaneous monitoring of PM₁.₀, PM₂.₅, PM₁₀, and TSP.
Constant Flow Control: Incorporates flow feedback for constant flow control, ensuring sampling volume stability and enhancing accuracy.
Built-in Protection: Features sheath gas protection and gas path protection functions.
Professional Design: Structural design by professional design institutes for easy installation.
Tiered Air Paths: Features dual-pump air paths with main channel for particulates and auxiliary channel for gas modules.
Data Stability: Equipped with temperature and humidity sensing, gas cross-interference algorithms, zero drift compensation, and calibration across measurement ranges.
Dynamic Dehumidification: Can be equipped with a dynamic heating dehumidification sampling system to avoid data distortion in humid environments.
Data Transmission: 4G, RS232/RS485.
Data Export: Features USB port and/or SD card slot, supporting local data export (includes local storage with capacity >530,000 records).
Weather Resistance: Protection against rain, snow, and lightning.
Traceability: Traceable to NIST (National Institute of Standards and Technology).
Resume Transmission: Features power failure protection and data resume/re-transmission upon network restoration.
Information & QC: Includes device information management, data management, and data quality control functions.
Local Display: Equipped with LCD display and local debugging functions.
Multi-stage Filtration: Incorporates a two-stage or higher filtration system to prevent foreign matter from affecting sensor accuracy and precision.
Service Life: Main unit >10 years; Particulate Matter Sensor >5 years; Gas Sensors >2 years.
Calibration/Zeroing: Supports automatic/manual zero calibration and calibration functions.
| Particulate Matter (PM) | |
| Measurement Method | Laser Scattering | 
| Measured Parameters | PM₂.₅, PM₁₀, PM₁₀₀, TSP | 
| Concentration Range | 0 - 30 mg/m³ | 
| Concentration Precision | 0.1 µg/m³ | 
| Concentration Accuracy | ±10% | 
| Inorganic Gases | |
| Measurement Method | Electrochemical Method | 
| Measured Parameters | SO₂, NO₂, CO, O₃, TVOC | 
| Concentration Range | SO₂: 0-1 ppm NO₂: 0-1 ppm CO: 0-200 ppm O₃: 0-5 ppm TVOC: 0-20 ppm | 
| Concentration Precision | SO₂: 0.001 ppm NO₂: 0.001 ppm CO: 0.01 ppm O₃: 0.001 ppm TVOC: 0.001 ppm | 
| Concentration Accuracy | SO₂: ±5% NO₂: ±5% CO: ±5% O₃: ±5% TVOC: ±5% | 
| Meteorological Parameters | |
| Temperature | Range: -50 ~ 100°C; Accuracy: ±0.3°C | 
| Humidity | Range: 0 ~ 100% RH; Accuracy: ±3% RH | 
| Wind Speed | Range: 0~30 m/s; Accuracy: ±1 m/s (≤10 m/s), ±10% (>10 m/s) | 
| Wind Direction | Range: 0~360°; Accuracy: ±3° | 
| Atmospheric Pressure | Range: 1~120 kPa; Accuracy: ±0.15 kPa | 
| Data Transmission | 4G transmission; Capable of uploading to data platforms; Compliant with China's standard HJ212-2017 communication protocol. | 
| Ingress Protection (IP) | IP53 | 
| Power Supply | AC 220V | 
| Output Interfaces | RS232, RS485, etc. | 
| Installation Method | Pole-mounted/Bracket-mounted | 
|   | 
 NMHC THC CH4 Online Gas Analyzer For Vocs Waste Gas Non-Methane Total Hydrocarbon
                                                                                    
                        
                        
                        
                                                            NMHC THC CH4 Online Gas Analyzer For Vocs Waste Gas Non-Methane Total Hydrocarbon
                                                    
                        
                     PM1.0 PM2.5 PM10 PM100 TSP Dust And Noise Online Monitoring System
                                                                                    
                        
                        
                        
                                                            PM1.0 PM2.5 PM10 PM100 TSP Dust And Noise Online Monitoring System
                                                    
                        
                     SO2 NO NO2 Online Continuous Emission Monitoring System CEMS Online Gas Analyzer
                                                                                        
                                                        
                        
                        
                        
                                                            SO2 NO NO2 Online Continuous Emission Monitoring System CEMS Online Gas Analyzer
                                                    
                        
                     Online Continuous Emission Monitoring System For Vocs Gas Chromatography Fid Non Methane Total Hydrocarbon Gas Analyzer
                                                                                        
                                                        
                        
                        
                        
                                                            Online Continuous Emission Monitoring System For Vocs Gas Chromatography Fid Non Methane Total Hydrocarbon Gas Analyzer
                                                    
                        
                     High Temperature Extraction Method CEMS Monitoring System For SO2 NO NO2 Fast Response Gas Analyzer
                                                                                        
                                                        
                        
                        
                        
                                                            High Temperature Extraction Method CEMS Monitoring System For SO2 NO NO2 Fast Response Gas Analyzer
                                                    
                        
                     Modular Online CEMS Continuous Emission Monitoring System For SO2 NO NO2 CO CO2 Gas Analyzer
                                                                                        
                                                        
                        
                        
                        
                                                            Modular Online CEMS Continuous Emission Monitoring System For SO2 NO NO2 CO CO2 Gas Analyzer
                                                    
                        
                     Automated Vocs Gas Analyzer CEMS Monitoring System For Non Methane Total Hydrocarbon
                                                                                        
                                                        
                        
                        
                        
                                                            Automated Vocs Gas Analyzer CEMS Monitoring System For Non Methane Total Hydrocarbon
                                                    
                        
                     Waste Incineration Gas Analyzer CEMS Monitoring Equipment HCl CO Continuous Emission Monitoring System
                                                                                        
                                                        
                        
                        
                        
                                                            Waste Incineration Gas Analyzer CEMS Monitoring Equipment HCl CO Continuous Emission Monitoring System
                                                    
                        
                     Online Gas Analyzer Dust CEMS Continuous Emission Monitoring System For HCl CO
                                                                                    
                        
                        
                        
                                                            Online Gas Analyzer Dust CEMS Continuous Emission Monitoring System For HCl CO
                                                    
                        
                     PT100 Cems Gas Analyzer Integrated Temperature Pressure Online Gas Monitoring System
                                                                                    
                        
                        
                        