| Sign In | Join Free | My futurenowinc.com | 
              
  | 
      
| Categories | Electronic Pressure Sensor | 
|---|---|
| Brand Name: | HONEYWELL | 
| Model Number: | ABPDANN010BGAA5 | 
| Place of Origin: | USA | 
| MOQ: | 1 | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 1500 | 
| Delivery Time: | 5-8 days | 
| Packaging Details: | Tube installation | 
| Supply voltage (Vsupply): | -0.3-6.0 Vdc | 
| Voltage on any pin: | -0.3 -Vsupply + 0.3 V | 
| Digital interface clock frequency: | 100 50 -400 800 kHz | 
| Storage temperature: | -40 [-40]- 85 [185] °C [°F] | 
| Company Info. | 
| ShenzhenYijiajie Electronic Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Product Description:
ABPDANN010BGAA5 Multi-scenario Application Basic Type Board Installation Pressure Sensor is 10bar
Features:
• Measures gage and differential
pressures
• Total Error Band (see Figure 1): ±1.5 %FSS
• Liquid media option: Allows for wet/
wet operation on dual ported devices
• Industry-leading long-term stability:
±0.25 %FSS
• Industry-leading accuracy: ±0.25 %FSS
BFSL
• Wide pressure range: 60 mbar to 10 bar
| 6 kPa to 1 MPa | 1 psi to 150 psi
• As small as 8 mm x 7 mm
• High burst pressures (see Table 7)
• Calibrated over temperature range of 0°C
to 50°C [32°F to 122°F]
• Operates from a single power supply of
either 3.3 Vdc or 5.0 Vdc
• Output: Ratiometric analog or I2C- or
SPI-compatible 12-bit digital
• Power consumption: 2 uA typical when
utilizing sleep mode option
• Meet IPC/JEDEC J-STD-020D.1
Moisture Sensitivity Level 1
requirements
• REACH and RoHS compliant
• Options: Internal diagnostic function,
liquid media, sleep mode, temperature
output
FIGURE 1. TOTAL ERROR BAND TABLE 1. ABSOLUTE MAXIMUM RATINGS1 CHARACTERISTIC MIN. MAX. UNIT Supply voltage (Vsupply) -0.3 6.0 Vdc Voltage on any pin -0.3 Vsupply + 0.3 V Digital interface clock frequency: I2 C SPI 100 50 400 800 kHz ESD susceptibility (human body model) 2 — kV Storage temperature -40 [-40] 85 [185] °C [°F] Soldering time and temperature: lead solder temperature (DIP) peak reflow temperature (Leadless SMT, SMT) 4 s max. at 250°C [482°F] 15 s max. at 250°C [482°F] 1Absolute maximum ratings are the extreme limits the device will withstand without damage. TABLE 2. ENVIRONMENTAL SPECIFICATIONS CHARACTERISTIC PARAMETER Humidity: all external surfaces internal surfaces of Liquid Media Option (T, V, F, G) internal surfaces of Dry Gases Option (N, D) 0 %RH to 95 %RH, non-condensing 0 %RH to 100 %RH, condensing 0 %RH to 95 %RH, non-condensing Vibration 15 g, 10 Hz to 2 kHz Shock 100 g, 6 ms duration Life1 1 million pressure cycles minimum Solder reflow J-STD-020-D.1 Moisture Sensitivity Level 1 (unlimited shelf life when stored at
Specifications:
| Response time | 1 - 0.46 ms | 
| Total Error Band7 | ±1.5- ±1.5 %FSS8 | 
| Accuracy | ±0.25 %FSS BFSL | 
| Output resolution | 12bits | 


                                 
                             |