| Sign In | Join Free | My futurenowinc.com | 
 | 
| Categories | Gas Detector Sensor | 
|---|---|
| Brand Name: | KACISE | 
| Model Number: | KQT-O2 | 
| Place of Origin: | CHINA | 
| MOQ: | 1PCS | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 1000 Piece/Pieces per Week negotiable | 
| Delivery Time: | 5-8 work days | 
| Packaging Details: | each unit has individual box and all boxes are packed in standard packages or customers requests available | 
| Certification: | CE | 
| Temperature Range: | -30℃ - 50℃ | 
| Detection Principle: | Electrochemical two-electrode | 
| Detection Range: | 0 - 25%VOL | 
| Maximum Load Concentration: | 30%VOL | 
| Output Signal: | 100±20 μA in air | 
| Load Resistance: | 100Ω | 
| Company Info. | 
| Xi'an Kacise Optronics Co.,Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
The OxySense Pro Sensor by KACISE is a high-precision oxygen detection solution designed as a dependable alternative to Alphasense. Utilizing advanced electrochemical two-electrode technology, it delivers accurate and stable oxygen level measurements with a detection range of 0-25% VOL. Ideal for medical oxygen generators, air quality monitors, and industrial applications, the OxySense Pro ensures fast response times (T90 < 20s), low power consumption, and excellent repeatability. KACISE’s commitment to innovation and quality makes this sensor a trusted choice for real-time oxygen monitoring, offering long-term stability and reliability in diverse environments.
1.Oxygen alarms in the mining field
2.Medical oxygen generators
3.Air quality detection instruments
4.Air purification equipment in underground parking lots and commercial areas
5.Air quality detection in vehicles, as well as the fresh air systems of in-vehicle purification equipment
1. High precision and long service life
2. Fast response speed and quick return to zero
3. Low power consumption and high sensitivity
4. Wide linear range
5. Strong anti-interference ability
6. Excellent repeatability and stability
| Project | Parameter | 
| Model | KQT-O₂ | 
| Detection Principle | Electrochemical two-electrode | 
| Detected Gas | O₂ | 
| Detection Range | 0 - 25%VOL | 
| Maximum Load Concentration | 30%VOL | 
| Output Signal | 100±20 μA in air | 
| Zero-point Drift | 0.6%VOL | 
| Resolution | 0.1%VOL | 
| Response Time | T90 < 20s | 
| Bias Voltage | 0 | 
| Load Resistance | 100Ω | 
| Temperature Range | -30℃ - 50℃ | 
| Humidity Range | 15% RH to 90% RH (no condensation) | 
| Repeatability | < ±2% output signal | 
| Long-term Stability | < 2% signal / month | 
| Linearity | Linear, regression coefficient R² = 0.999 | 
| Working Pressure | 90 to 110 kPa | 
| Shelf Life | 12 months after delivery | 
| Service Life | 2 years | 
|   | 
 Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus Output
                                                                                    
                        
                        
                        
                                                            Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus Output
                                                    
                        
                     KFK - G60 - TSP Factory Dust Surveillance Pro
                                                                                    
                        
                        
                        
                                                            KFK - G60 - TSP Factory Dust Surveillance Pro
                                                    
                        
                     R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared Detection And IP54 Protection
                                                                                    
                        
                        
                        
                                                            R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared Detection And IP54 Protection
                                                    
                        
                     KFK - G60 Flammable Gas Sentinel
                                                                                    
                        
                        
                        
                                                            KFK - G60 Flammable Gas Sentinel
                                                    
                        
                     Refrigerant (R744) Leakage Monitoring Sensor KGD - AM - 206
                                                                                    
                        
                        
                        
                                                            Refrigerant (R744) Leakage Monitoring Sensor KGD - AM - 206
                                                    
                        
                     Laser Scattering Sampling Method Industrial Dust Guardian KFK-G60-TSP with DC24V±15% Voltage
                                                                                    
                        
                        
                        
                                                            Laser Scattering Sampling Method Industrial Dust Guardian KFK-G60-TSP with DC24V±15% Voltage
                                                    
                        
                     KGD OPC 201 28.3L Particle Counter with Multi channel Counting Efficiency of 50% 0.3μm and 100% ≥0.5μm
                                                                                    
                        
                        
                        
                                                            KGD OPC 201 28.3L Particle Counter with Multi channel Counting Efficiency of 50% 0.3μm and 100% ≥0.5μm
                                                    
                        
                     KFK G60 TSP Dust Hazard Area Monitor Sensor PM2.5 PM10 for Quick Detection Response
                                                                                    
                        
                        
                        
                                                            KFK G60 TSP Dust Hazard Area Monitor Sensor PM2.5 PM10 for Quick Detection Response
                                                    
                        
                     Portable Particle Counter KGD OPC 202 Power-on Stabilization Time ≤8s Detection Range 0 1
                                                                                    
                        
                        
                        
                                                            Portable Particle Counter KGD OPC 202 Power-on Stabilization Time ≤8s Detection Range 0 1
                                                    
                        
                     Professional Electrical Fire Monitoring System For Comprehensive Monitoring
                                                                                    
                        
                        
                        
                                                            Professional Electrical Fire Monitoring System For Comprehensive Monitoring