| Sign In | Join Free | My futurenowinc.com | 
              
  | 
      
| Categories | Precision Air Conditioner | 
|---|---|
| Applicable Industries: | Manufacturing Plant | 
| Type: | industrial air conditioner | 
| Place of Origin: | Guangdong, China | 
| Brand Name: | visench | 
| Operating Voltage: | 380/400 VAC | 
| Mounting: | Floor Standing | 
| Warranty: | 1 Year | 
| Key Selling Points: | High Safety Level | 
| Airflow: | 2000m³/h | 
| Machinery Test Report: | Provided | 
| Video outgoing-inspection: | Provided | 
| Warranty of core components: | 1 Year | 
| Core Components: | Pressure vessel, Motor, Gearbox | 
| Weight (KG): | 120 KG | 
| Category: | Cooling only | 
| Indoor unit model: | EFA008C1Y0A | 
| Outdoor unit model: | ECA012 | 
| Energy efficiency ratio: | 3.6 | 
| Power Specifications: | 380VAC/50HZ | 
| Cooling capacity (kW): | 8KW/13KW | 
| Number of presses: | 1 | 
| Air supply method: | Come forward to blow the air | 
| Evaporator form: | large area U type evaporator | 
| Fan form: | Biaxial flow typeDCfan | 
| Condition: | New | 
| Price: | $1,215.43 - $1,714.29/pieces | 
| Company Info. | 
| Visench Technology Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 

Category  | Cooling only  | ||||
Indoor unit model  | EFA008C1Y0A  | EFA013C1Y0A  | |||
Outdoor unit model  | ECA012  | ECA019  | |||
Energy efficiency ratio  | 3.6  | 3.45  | |||
Power Specifications  | 380VAC/50HZ  | ||||
Indoor unit maximum current  | 7A  | 12A  | |||
Outdoor unit maximum current  | 0.85A  | 1.7A  | |||
Recommended input circuit breaker  | 16A/4P  | 16A/4P  | |||
Indoor unit cable (recommended)  | 5*2.5mm²  | 5*2.5mm²  | |||
Outdoor unit cable (recommended)  | 3*1mm²  | ||||
Inner and outer unit signal cables (recommended)  | none  | ||||
Cooling capacity (kW)  | 8  | 13  | |||
Sensible cooling capacity (kW)  | 7.36  | 12.22  | |||
Sensible heat ratio  | 0.92  | 0.94  | |||
Air volume (m³/h)  | 2800  | 3500  | |||
Return air volume (m³/h)  | 2800  | 3500  | |||
Heat exchange capacity(kw)  | 11  | 17  | |||
compressor  | Number of presses  | 1  | |||
Fixed frequency/frequency conversion  | Fixed frequency  | ||||
Compressor Type  | Highly Rotary Compressor  | ||||
Indoor fan  | Air supply method  | Come forward to blow the air  | |||
Number of fans  | 2  | ||||
Fan form  | Biaxial flow type DCfan  | ||||
outdoor fan  | Number of fans  | 1  | 2  | ||
Fan form  | Axial Fan  | ||||
Evaporator form  | large area U type evaporator  | ||||
Expansion valve  | type  | Electronic expansion valve  | |||
Filter  | filter level  | Medium and high efficiency:G2class  | |||
refrigerant(5Copper pipes are available within meters)  | type  | R410A  | |||
Indoor unit factory precharge (kg)  | 1  | 1.5  | |||
Indoor unit factory precharge (kg)  | 1  | 1.5  | |||
Noise value(dB)  | Indoor unit  | 56  | 58  | ||
The outdoor unit  | 55  | 60  | |||
Dimensions(mm)  | Indoor unit(Width*deep*high)  | 510*425*1865  | |||
The outdoor unit(Width*deep*high)  | 960*370*810  | 960*370*1260  | |||
weight(kg)  | Indoor unit  | 87  | 102  | ||
The outdoor unit  | 34  | 53  | |||
Recommended size for takeover (mm)  | trachea  | 12.7(Coil)  | 16(Coil)  | ||
liquid pipe  | 9.52(Coil)  | 9.52(Coil)  | |||
Water inlet pipe (constant temperature and humidity)  | G1/2"  | ||||
drain pipe  | IDΦ19mm  | ||||
Takeover allowed length (m)  | Equivalent length of internal and external machine pipes  | ≤20(If the project exceeds the requirements, contact the local
pre-sales engineer)  | |||
Difference in installation position between indoor and outdoor
units  | The outdoor unit is higher than the indoor unit: ≤10(If the project
exceeds the requirements, contact the local pre-sales engineer)  | ||||
Outdoor unit is lower than indoor unit: ≤5(If the project exceeds
the requirements, contact the local pre-sales engineer)  | |||||
Design usage conditions  | indoor ambient temperaturetwenty four℃/wet bulb temperature17℃;
outdoor ambient temperature35℃  | ||||
Standard (functional) parts  | high/Low pressure protection switch, pressure sensor  | ||||
Optional (functional) parts  | 1, extension components (one-way pipeline length exceeds20m
configuration, per5~7.5Need to add an oil trap),Maximum extension to30m;2, low temperature components (the outdoor temperature is lower than-15℃ region configuration), after configuration, it can reach-35℃  | ||||
Features  | 1,4.3Inch button control screen;2, power-off memory, automatic
restart when incoming call;3, group control networking (maximum32tower);4, Intelligent protection: power phase loss, over-voltage, under-voltage, reverse phase protection alarm, compressor high and low pressure protection alarm, high environment in the machine room/Low temperature alarm;5, monitor and display the operating status of the outdoor unit: condensing pressure, fan speed, power signal, speed regulation signal, etc.;6, History storage500strip  | ||||















                                 
                             |