Product Description:
Classified according to the characteristics of the protected area
Full flooding fire extinguishing system: The system is to spray a
certain concentration of fire extinguishing agent to the protection
area within the specified time, and make it evenly filled with the
entire protection area, and form a fire extinguishing concentration
in the space of the protection area to achieve the purpose of fire
extinguishing. This system is suitable for the space where the
protection area cannot be closed, such as some large computer
rooms, power distribution rooms, etc.
Local application fire extinguishing system: It is a fire
extinguishing system that points to the protection object to
directly spray the fire extinguishing agent at the design injection
rate and lasts for a certain time. It is mainly used to protect
local dangerous areas in a large enclosed space, such as the
storage area of valuable equipment in a large warehouse.
Classification by structural form
Pipe network system: the fire extinguishing agent is transported to
the protected area through the pipe network, and the pipe network
system is divided into unit independent system and combined
distribution system. The unit independent system is a set of fire
extinguishing agent storage device to protect a fire extinguishing
system in a protected area; Combined distribution system is to use
a set of fire extinguishing agent storage device through the pipe
network selection valve and other components, to protect multiple
protection areas of the fire extinguishing system, this system can
save the number of fire extinguishing agent storage devices, reduce
costs, but the system is relatively complex.
No pipe network (cabinet) system: The fire extinguishing agent
storage device and nozzle and other components are combined
together to form a fire extinguishing device that can work
independently, usually installed in the protected area. Its
advantage is that it is easy to install, does not require complex
pipe networks, and is suitable for small protection areas, such as
small computer rooms and small distribution boxes.
Technical Parameters:
| Technical Parameter | Value |
|---|
| System Blowdown Time | Computer Room ≤8s, Other ≤10s |
| Scope of Work | 0°C~50°C |
| Starting Mode | Automatic, Electrical Manual, Mechanical Emergency |
| Storage Pressure | 5.6MPA(20°C) |
| Pattern of Extinguishing | Enclosed Flooding |
| Filling Density | ≤1080kg/m3 |
| Fire Extinguishing Design Concentration | 8~10℃ |
| Name | FM200 System |
| Maximum Working Pressure | 8MPA(20°C) |
FM200 Fire Alarm System, Aerosol Fire Suppression System, Inert Gas
Fire Suppression System
Applications:
Data centers and computer rooms: These are places where large amounts of electronic equipment are
stored and electrical fire risks are high. Hfc-propane fire
extinguishing systems can quickly extinguish fires without damaging
equipment and protect data security.
Distribution rooms and substations: Essential for the protection of
power facilities, because fires in these places can lead to serious
consequences such as widespread blackouts, and HFC-propane fire
suppression systems can quickly and effectively extinguish
electrical fires.
Archives and libraries: where precious archives and books are stored, a clean,
pollution-free fire extinguishing system is needed, and
heptafluoropropane fire extinguishing system meets the
requirements.
Maintenance requirement
Check the system regularly, including the pressure check of the
fire extinguishing agent bottle group, generally check the bottle
group pressure at least once a month to ensure that the pressure is
within the specified range. Check pipes and fittings for leakage,
and use soapy water and other methods to detect leakage. It is also
necessary to perform functional tests on the electrical components
of the system, such as fire detectors, controllers, etc., to ensure
that the system can start and operate normally. In addition, every
five years should be a comprehensive test of the system, including
fire extinguishing agent quality testing.

FAQ:
• Efficient management system
• More than 10 years of experience in gas fire fighting industry
• Advanced equipment and professional engineers
• We provide 8×6 hr technical support and after-sales service
Frequently Asked Questions
-----------------------------------------------------------------------------------
Q1Are you a manufacturer or a trading company?
A1: We are the manufacturer.
Q2: Do you have OEM orders?
A2: Yes, according to the customer's requirements.
Q3: Where is your factory located? How do I get there?
A3: Our factory is located in Dongzhou Industrial Park, Xintang
Town, Zengcheng District, Guangzhou City, Guangdong Province,
China.
You are very welcome to visit our factory.