| Basic parameters | |
| Measuring medium | Liquid or gas (compatible with contact materials) |
| Pressure range | -0.1~0~7MPa (see range selection table class=”info” for details) |
| Pressure mode | Gauge pressure, absolute pressure, negative pressure |
| Medium temperature | -40~85℃ |
| Connection time | 20ms |
| Stable class=”info” performance | ±0.1%FS/year |
| Temperature drift | ±0.01%FS/℃ (within temperature compensation range) ±0.05%FS/℃
(outside temperature compensation range) |
| Temperature compensation | -20~80℃ |
| Explosion-proof type | Intrinsically safe Ex ia ⅡC T6 Ga (4~20mA output only) |
| Protection level | IP65 Note/The above protection level refers to the level achieved after
the electrical connection is complete. |
| Accuracy level | 0.1%FS, 0.25%FS |
| Response frequency | Analog signal output ≤30Hz Digital signal output ≤5Hz |
| Resolution | Analog output 0.01%FS, digital output 0.05%FS |
| Overall weight | ≈381g |
| Load characteristics | |
| Voltage Type | ≥10kΩ |
| Current Type | Load ≤{(Us-12)÷0.02}Ω (Us=supply voltage) |
| Environmental conditions | |
| Ambient temperature | -40~85℃ |
| Ambient humidity | 0%~95%RH (no condensation and no condensation) |
| Overpressure and explosion | |
| Overload pressure | 0.2MPa, 0.27MPa, 0.33MPa, 0.53MPa, 0.67MPa, 1.2MPa, 1.67MPa,
2.67MPa, 4MPa, 7MPa, 0.27MPa, 0.33MPa, 0.53MPa, 0.67MPa, 1.2MPa |
| Burst pressure | 0.3MPa, 0.4MPa, 0.5MPa, 0.8MPa, 1MPa, 1.8MPa, 2.5MPa, 4MPa, 6MPa,
8MPa, 0.4MPa, 0.5MPa, 0.8MPa, 1MPa, 1.8MPa |
| Overall material | |
| Diaphragm | Ceramic (contacting the measured medium) |
| Process connection | PVDF polyvinylidene fluoride (contacting the measured medium) |
| shell | 304 Stainless Steel |
| Core seal | See the pressure and burst chart (contact with the measured medium) |
| ED Circle | Fluorine rubber |
| Hirschmann connector | ABS engineering plastics |
| Mechanical stability | |
| Vibration resistance | 10g (20…2000Hz) in accordance with IEC60068-2-6 standard |
| Impact resistance | 500g/ms, in compliance with IEC60068-2-27 standard |
| Electrical protection | |
| Short circuit protection | permanent |
| Reverse polarity protection | No damage, but not working |
| Insulation resistance | ≥100MΩ 500VDC |
| Dielectric strength | 500VAC |
| Output Limitation | |
| 4-20mA | 4mA~20mA |
| RS485 | 0~2000 |
| 0~10VDC | 0.001VDC~10VDC |
| 0~5VDC | 0.001VDC~5VDC |
| 1~5VDC | 0.001VDC~5VDC |