| Sign In | Join Free | My futurenowinc.com | 
 | 
| Categories | RCD Loop Tester | 
|---|---|
| Brand Name: | PEAKMETER | 
| Model Number: | PM5909 | 
| Certification: | CE | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | Negotiation | 
| Payment Terms: | T/T | 
| Supply Ability: | 150,000 Pcs Per Month | 
| Delivery Time: | 5-40 work days | 
| Packaging Details: | Product Size: 200mm x 155mm x76mm Product Weight:500g(2.0lb) | 
| Display Type: | Digital Only | 
| Function 1: | RCD Test | 
| Single-phase electric power: | 180V~264V/50Hz | 
| Data Logging and Recall: | 99 groups | 
| Three-phase electric power: | 360V~440V/50Hz | 
| Function 2: | Over temperature detection | 
| Company Info. | 
| Guilin Huayi Peakmeter Technology Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
English User Manual:https://drive.google.com/open?id=1sf9LsOu_x0tWCr9Yo0qIbZqYqJNVH2i4
| Range | Testing Scope | Accuracy | Rated residual current | 
| X 1/2 | 0~2000ms (0°/180°) | Testing current:-8%~0% Testing time:±(1%+3ms) | 10/20/30/100/200 /300/500mA | 
| X 1 | 0~2000ms (0°/180°) | Testing current:0%~+8% | 10/20/30/100/200 /300mA | 
| 0~200ms(0°/180°) | Testing time:±(1%+3ms) | 500mA | |
| X 2 | 0~200ms(0°/180°) | Testing current:0%~+8% Testing time:±(1%+3ms) | 10/20/30/100 /200mA | 
| X 5 | 0~200ms(0°/180°) | Testing current:0%~+8% Testing time:±(1%+3ms) | 10/20/30/100mA | 
| AUTO RAMP | 40%~110% of the rated leakage current in steps of 5%; Testing time: 300ms X 15 | Testing current:-2%~+8% Testing time:±(1%+3ms) | 10/20/30/100/200 /300/500mA | 
| Working voltage | Single-phase: 180V~246V/50Hz Three-phase: 360V~440V/50Hz | ||
| AC voltage testing indicators | 30~40V(VL-PE,VL-N) | ±(2%+4) | |
| Function | |||
| Testing of RCD operation time | √ | ||
| The AUTO RAMP testing | √ | ||
| Fault voltage (UF) detection | √ | ||
| Wiring inspection | √ | ||
| The selection of phase angle | √ | ||
| Testing current options | √ | ||
| Over temperature detection | √ | ||
| Low battery detection | √ | ||
| Automatic shutdown | √ | ||
| Backlight | √ | ||
| RCD testing | √ | ||
| Save data | 99groups | ||
| General | |||
| Power Supply | 6*AA LR6 Alkaline battery | ||
| Size | 200mm*155mm*76mm | ||
| Weight | 500g | ||
MS5909 is a leakage switch tester controlled by intelligent microcontroller chip, which has the characteristics of high precision, robustness, durability and easy operation. This instrument can be used in 220V single-phase power system and 380V three-phase power system. It can not only test the operating time and operating current of the leakage light, but also has the test function of wiring inspection, fault voltage and system voltage. The tester has the functions of phase Angle selection, overtemperature detection, low voltage detection, LCD backlight and automatic shutdown. This is a detection instrument for leakage protection devices in various occasions, easy to carry and use.



|   | 
 Auto / manual range RCD Loop Tester Digital Multimeter for GFCI  Trip - out Current / Time
                                                                                        
                                                        
                        
                        
                        
                                                            Auto / manual range RCD Loop Tester Digital Multimeter for GFCI  Trip - out Current / Time
                                                    
                        
                     High Performance RCD Loop Tester Multimeter USB Interface High Accuracy
                                                                                        
                                                        
                        
                        
                        
                                                            High Performance RCD Loop Tester Multimeter USB Interface High Accuracy
                                                    
                        
                     Auto Power Off Digital RCD Loop Tester Trip - Out Current / Time For GFCI
                                                                                        
                                                        
                        
                        
                        
                                                            Auto Power Off Digital RCD Loop Tester Trip - Out Current / Time For GFCI
                                                    
                        
                     100 Groups Digital RCD Tester Data Logging , GFCI Earth Loop Impedance Meter
                                                                                        
                                                        
                        
                        
                        
                                                            100 Groups Digital RCD Tester Data Logging , GFCI Earth Loop Impedance Meter
                                                    
                        
                     Digital Resistance RCD Loop Tester Multifunctional High Reliability And Safety
                                                                                        
                                                        
                        
                        
                        
                                                            Digital Resistance RCD Loop Tester Multifunctional High Reliability And Safety
                                                    
                        
                     USB Interface RCD Loop Tester Multimeter Stable Performance For GFCI
                                                                                        
                                                        
                        
                        
                        
                                                            USB Interface RCD Loop Tester Multimeter Stable Performance For GFCI